Peerless IBA3-W Installation guide

Category
Security device components
Type
Installation guide
Models: IBA3, IBA3-W
Installation and Assembly:
Recessed Cable Management and Power Storage
Accessory Box
ISSUED: 12-27-10 SHEET #: 120-9100-2 06-13-11
2300 White Oak Circle • Aurora, Il 60502 • (800) 865-2112 • Fax: (800) 359-6500 • www.peerlessmounts.com
2 of 6 ISSUED: 12-27-10 SHEET #: 120-9100-2 06-13-11
Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112
Note: Read entire instruction sheet before you start installation and assembly.
• Do not begin to install your Peerless product until you have read and understood the instructions and warnings
contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, for US
customers please call Peerless customer care at 1-800-865-2112, for all international customers, please contact
your local distributor.
• This product should only be installed by someone of good mechanical aptitude, has experience with basic building
construction, and fully understands these instructions.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
• If mounting to wood wall studs, make sure that mounting screws are anchored into the center of the studs. Use of
an "edge to edge" stud fi nder is highly recommended.
• Tighten screws fi rmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding
power.
• This product is intended for indoor use only. Use of this product outdoors could lead to product failure and personal
injury.
WALL CONSTRUCTION HARDWARE REQUIRED
Wood Stud Included
Metal Stud Do not attach except with Peerless accessory kit ACC415;
Contact Customer Service for Peerless accessory kit ACC415
Brick Contact Qualifi ed Professional
Drywall Do not attach except with Peerless accessory kit ACC415;
Contact Customer Service for Peerless accessory kit ACC415
Other or unsure? Contact Qualifi ed Professional
WARNING
Table of Contents
Parts List.................................................................................................................................................................................3
Installation to Wood Wall ........................................................................................................................................................4
Cable Management ................................................................................................................................................................5
Tools Needed for Assembly
• stud fi nder ("edge to edge" stud fi nder is recommended)
• phillips screwdriver
• drill
• 3/16" (5mm) drill bit for wood studs
• level
3 of 6 ISSUED: 12-27-10 SHEET #: 120-9100-2 06-13-11
Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112
Before you begin, make sure all parts shown are included with your product.
E
D
A
F
B
GI
H
C
Parts may appear slightly different than illustrated.
IBA3 IBA3-
W
Description Qty. Part # Part #
A
in-wall box 1 120-P1186 120-2186
B1-1/2" wood screw 4 500-1090 500-4090
C4mm security driver 1 560-1133 560-1133
Dcable bushing 1 590-1295 590-2295
Ecable management clips 2 590-1166 590-1166
Fplastic finishing cap 1 590-1123 590-2123
Gcable tie 2 590-1168 590-1168
Haccess plate 1 120-P1187 120-2187
IM5 x 6mm phillips screw 5 520-1023 520-2214
Parts List
4 of 6 ISSUED: 12-27-10 SHEET #: 120-9100-2 06-13-11
Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112
In-wall box (A) can be installed between two
studs 16" off center. Use a stud fi nder to locate
the edges of the stud. Use of an edge-to-edge
stud fi nder is highly recommended. Based on its
edges, draw two vertical lines down the inside
edges of two stud’s. Mark desired center of in-wall
box. Draw a horizontal line 2-5/16" (59mm) above
desired center of in-wall box. Draw a second
horizontal line 4-7/16" (114mm) below fi rst line
to outline wall opening between inside edges of
studs. Remove drywall inside cut outline.
Insert in-wall box (A) into wall until fl ange is fl ush
with drywall as shown in fi g. 1.1.
Level in-wall box, and mark center of the four
mounting holes. Make sure that the mounting
holes are on stud centerlines. Drill four 3/16"
(5mm) dia. holes 1-1/2" (38mm) deep. Make sure
in-wall box is level, and secure it using four wood
screws (B) as shown in fi g. 1.2.
Installation to Wood Stud Wall
1
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
• Tighten wood screws so that in-wall box is fi rmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud fi nder
is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs.
Installers are responsible to provide hardware for other types of mounting situations.
WARNING
4-7/16"
(114mm)
13-1/8"
(333mm)
g. 1.1
STUDS
A
FLANGE
TOP LINE
OF CUT
OUTLINE
CENTER OF
IN-WALL BOX
2-5/16"
(59mm)
B
g. 1.2
5 of 6 ISSUED: 12-27-10 SHEET #: 120-9100-2 06-13-11
Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112
E
H
I
D,F G
CABLES
g. 2.2 g. 2.3
g. 2.1
© 2011, Peerless Industries, Inc. All rights reserved.
All other brand and product names are trademarks or registered trademarks of their respective owners.
Attach access plate (H) to in-wall box (A) with fi ve M5 x 6mm phillips screws (I) as shown in fi gure 2.1. Access
plate knockout may be removed for optional installation of electrical gang box.
Insert up to two cable management clips (E) into the desired positions in the in-wall box as shown in fi gure 2.2 for
routing cables.
Insert cable bushing (D) into in-wall box for routing cables through in-wall box. Plastic fi nishing cap (F) may also
be used if cable management is unnecessary.
Use cable ties (G) to secure cables to cable management clips as shown in fi gure 2.3.
Cable Management
2
ACCESS PLATE
KNOCKOUT
6 of 6 ISSUED: 12-27-10 SHEET #: 120-9100-2 06-13-11
Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112
© 2011 Peerless Industries, Inc.
Peerless Industries, Inc. (“Peerless”) warrants to original end-users of Peerless® products will be free from defects in material and workmanship, under normal
use, for a period of fi ve years from the date of purchase by the original end-user (but in no case longer than six years after the date of the product’s manufacture).
At its option, Peerless will repair or replace, or refund the purchase price of, any product which fails to conform with this warranty.
In no event shall the duration of any implied warranty of merchantability or fi tness for a particular purpose be longer than the period of the applicable
express warranty set forth above. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
This warranty does not cover damage caused by (a) service or repairs by the customer or a person who is not authorized for such service or repairs by Peerless,
(b) the failure to utilize proper packing when returning the product, (c) incorrect installation or the failure to follow Peerless’ instructions or warnings when installing,
using or storing the product, or (d) misuse or accident, in transit or otherwise, including in cases of third party actions and force majeure.
In no event shall Peerless be liable for incidental or consequential damages or damages arising from the theft of any product, whether or not secured
by a security device which may be included with the Peerless® product. Some states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you.
This warranty is in lieu of all other warranties, expressed or implied, and is the sole remedy with respect to product defects. No dealer, distributor, installer or other
person is authorized to modify or extend this Limited Warranty or impose any obligation on Peerless in connection with the sale of any Peerless® product.
This warranty gives specifi c legal rights, and you may also have other rights which vary from state to state.
LIMITED FIVE-YEAR WARRANTY
www.peerlessmounts.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Peerless IBA3-W Installation guide

Category
Security device components
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI