ABB SACE Emax 2 User manual

Type
User manual

This manual is also suitable for

ABB SACE Emax 2 is a remote resetting coil designed for use with E2.2-E4.2-E6.2 circuit breakers, offering enhanced control and flexibility in electrical systems. With its efficient trip-reset mechanism, it enables quick and easy resetting of tripped circuit breakers, reducing downtime and improving system reliability. The compact design of the ABB SACE Emax 2 allows for easy installation and integration into existing electrical setups, making it a convenient solution for various applications.

ABB SACE Emax 2 is a remote resetting coil designed for use with E2.2-E4.2-E6.2 circuit breakers, offering enhanced control and flexibility in electrical systems. With its efficient trip-reset mechanism, it enables quick and easy resetting of tripped circuit breakers, reducing downtime and improving system reliability. The compact design of the ABB SACE Emax 2 allows for easy installation and integration into existing electrical setups, making it a convenient solution for various applications.

SACE Emax 2
E2.2-E4.2-E6.2
C
Doc. N.° 1SDH001000R0606 - ECN000076574 - Rev. C
B
A
1
2
OK
OK
1
2
Bobina di riarmo da remoto YR - E2.2-E4.2-E6.2
Remote resetting coil YR - E2.2-E4.2-E6.2
ckstellspule ferngesteuert YR - E2.2-E4.2-E6.2
Bobine de réarmement à distance YR - E2.2-E4.2-E6.2
Bobina de rearme a distancia YR - E2.2-E4.2-E6.2
CLICK TO PLAY
2
1
SACE Emax 2 | ABB
1
2
1
2
1
1
1
2
2
2
90°
3
1
2
SACE Emax 2 | ABB
3
4
3
1
F
2
SACE Emax 2 | ABB
5
6
1
0.6 Nm
3
F
2
5.3 lb in
INSERTION SEQUENCE YR
- Perform trip test operation without
reset YR or the TU RESET push-button
- Insert microswitch YR
EINGABEFOLGE YR
- Ausführen von trip test betrieb ohne
Rückstellen YR oder die TU RESET-Taste drücken
- Mikroschalter YR einfügen
SÉQUENCE D'INSERTION YR
- Exécuter l'opération de trip reset sans
remise à zéro YR ou le bouton de TU RESET
- Insérez le micro-interrupteur YR
SECUENCIA DE INTRODUCCIÓN YR
- Efectuar l'operación de trip reset sin
resetear YR o el pulsador de TU RESET
- Introducir el microinterruptor YR
SEQUENZA INSERIMENTO YR
- Eseguire operazione di trip test senza
resettare YR o il pulsante di TU RESET
- Inserire microinterruttore YR
1
A
A
7
10
SACE Emax 2 | ABB
8 9
APPLY VOLTAGE LABEL
(FRONT AND SIDE)
90°
1
2
3
2
2
2
2
1
1
1
1
2
1
1,5 Nm
13.3 lb in
For more information please contact:
ABB S.p.A.
Via Pescaria, 5
24123 Bergamo - Italy
11
F
B
1
2
"CLICK"
W
B
1
2
"CLICK"
A4
X
XV
X
XV
A1
A4
+
~
SR
~
-
R2
R2
R2
YR
R1
R1
R1
14
© Copyright 2013-2018 ABB. All rights reserved.
www.abb.com
AC
DC
24 V
Note 1
Note 1
110 V
Note 1
Note 1,2
220 V
Note 1
Note 1,2
Note 2
- L'attivazione della bobina deve essere eseguita mediante un impulso di durata max 50ms.
Non è previsto il funzionamento con tensione permanentemente applicata all'accessorio.
- The coil activation must be done by an impulse that last not more than 50ms.
The operation with voltage permanently applied to the accessory is not possible.
- Die Aktivierung der Spule muss mit einem Impuls der Höchstdauer von 50ms erfolgen.
Der Betrieb mit ständig am Zubehörteil anliegender Spannung ist nicht vorgesehen.
- L'activation de la bobine doit être effectué avec un impulsion durée 50ms au maximum.
N'est pas attendu le fonctionnement avec tension appliquée de manière permanente à l'accessoire.
- La activación de la bobina se deberá efectuar mediante un impulso de duración 50ms como máximo.
No es previsto el funcionamiento con tensión permanentemente aplicada en el accessorio.
Note 1
- L'attivazione della bobina deve essere eseguita mediante un impulso di durata minima 20ms.
- The coil activation must be done by an impulse that last not less than 20ms.
- Die Aktivierung der Spule muss mit einem Impuls der Mindestdauer von 20ms erfolgen.
- L'activation de la bobine doit être effectué avec un impulsion durée 20ms au minimum.
- La activación de la bobina se deberá efectuar mediante un impulso de duración 20ms como minimo.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

ABB SACE Emax 2 User manual

Type
User manual
This manual is also suitable for

ABB SACE Emax 2 is a remote resetting coil designed for use with E2.2-E4.2-E6.2 circuit breakers, offering enhanced control and flexibility in electrical systems. With its efficient trip-reset mechanism, it enables quick and easy resetting of tripped circuit breakers, reducing downtime and improving system reliability. The compact design of the ABB SACE Emax 2 allows for easy installation and integration into existing electrical setups, making it a convenient solution for various applications.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI