Balance KH 5502 Operating Instructions Manual

Category
Personal scales
Type
Operating Instructions Manual

This manual is also suitable for

KOMPERNASS GMBH · BURGSTRASSE 21 · D-44867 BOCHUM
www.kompernass.com
ID-Nr.: KH5502/14-06/07-V1
UK
IB_KH5502_14_KOE5319_UK 06.07.2007 12:31 Uhr Seite 1
Digital glass scales KH 5502 / 5514
Operating Instructions
KH 5502
KH 5514
IB_KH5502_14_KOE5319_UK 06.07.2007 12:31 Uhr Seite 2
IB_KH5502_14_KOE5319_UK 06.07.2007 12:32 Uhr Seite 3
KH 5514
IB_KH5502_14_KOE5319_UK 06.07.2007 12:32 Uhr Seite 4
IB_KH5502_14_KOE5319_UK 06.07.2007 12:32 Uhr Seite 5
IB_KH5502_14_KOE5319_UK 06.07.2007 12:32 Uhr Seite 6
Content Page
Safety Instructions 4
Technical Data 4
Device Description 4
Purpose 4
Included in delivery 5
Commissioning 5
Use 6
Warning Displays 6
Replacing the Batteries 7
Use and Storage 7
Cleaning 8
Troubleshooting 8
Disposal 8
Guarantee and service 8
Importer 9
- 3 -
Read the operating instructions carefully before using the appliance for the first
time and preserve this booklet for later reference. Hand over the manual to anyone,
whom you pass on the appliance to.
IB_KH5502_14_KOE5319_UK 06.07.2007 12:32 Uhr Seite 3
- 4 -
Digital Glass Scale
Safety Instructions
Hazard!
Ensure that no liquid gets into the scale
or into the display. This can cause an
electrical shock hazard!
This appliance is not intended for use by
children or other persons without assi-
stance or supervision if their physical,
sensory or mental capabilities prevent
them from using it safely. Children
should be supervised to ensure that they
do not play with the appliance.
Warning!
Do not place the scale in the direct vici-
nity of heat sources. Scale and display
may only be operated at temperatures
between 10° and 40°C. At higher or
lower temperatures malfunctions or
permanent damage can occur.
Do not charge the scale with weight in
excess of 180 kg / 396 lb!
This can irreparably damage the scale
Caution!
Old batteries can leak battery acid. In
the event of the batteries leaking acids,
wear protective gloves. Clean the bat-
tery compartment with a dry cloth.
Remove the batteries if you will not be
using the scale for a longer period of time.
Please note!
Avoid electrostatic charging and dischar-
ging. Electrostatic charging or dischar-
ging can cause incorrect displays or sud-
denly switch-off the scale.
No liability/guarantee is assumed for da-
mages caused by…
opening the scale housing
repair work that is not performed by
qualified personnel
improper user of the scale
Technical Data
Maximum load bearing
capacity: 180 kg/396 lb
Tolerance Range: +/- (1% + 0.1kg/0.2lb)
(at 30 kg - 180 kg )
Minimum measurable
weight: 3 kg/6.6 lb
Selectable measurement
units: kg/lb
Scaling: 0.1 kg/0.2 lb
Operating temperature: 10 °C - 40 °C
Display for low battery power
Overload display
Fault display
Battery operation: 2 x CR2032 / 3V
(Lithium batteries)
Device Description
Display
Battery compartment
Safety glass
Selector switch (kg / lb)
Purpose
These digital glass scale is exclusively
intended
as personal scale
for use in private households
IB_KH5502_14_KOE5319_UK 06.07.2007 12:32 Uhr Seite 4
- 5 -
Included in delivery
Digital glass scale
2 x CR2032 / 3V lithium batteries
Operating instructions
Warranty card
Before using the appliance for the first
time, check to ensure that the contents
are complete and undamaged.
Commissioning
1. Remove the cover of the battery com-
partment. Remove the insulation strip
from the battery compartment and
insert the batteries back into the bat-
tery compartment with the correct
polarity.
2. Place the cover back on the battery
compartment and press it down until
you hear it snap into place.
3. Set the desired unit of weight
(kg or lb) by pressing the selector
switch.
Place your glass scale on a flat, solid
surface. Please ensure that both the
floor where the weigh scales are set
up and the surface of the weigh scales
are not wet to ensure that nobody
slips.
Please note!
The glass scale contains sensitive electro-
nic components and must therefore not
be installed
close to heat sources
in environments that are exposed to
extreme humidity
IB_KH5502_14_KOE5319_UK 06.07.2007 12:32 Uhr Seite 5
Use
1. Tap your foot lightly on the centre of
the scale until “HI” appears on the
LCD display.
2. Stand with both feet on the scale on-
ce “0.0” appears on the LCD display.
Stand calmly and without shifting
your weight.
3. During weighing, the “kg/lb” LCD di-
splay flashes and the displayed value
rises until your weight has been de-
termined.
4. The “kg/lb” display now stops flas-
hing and your weight is displayed in
grades of 0.1 kg/0.2 lb.
Attention: never jump on to the scale as
this may cause damage.
- 6 -
Warning Displays
“O_Ld” appears in the LCD display if the
weight exceeds the maximum weighing
capacity of 180 kg/396 lb. Step off the
scale immediately as you may otherwise
cause damage.
Replace the batteries if “Lo” appears in
the display.
The scale is unable to measure the
weight if “Err” appears in the display.
Step off the scale in this case, wait for a
few seconds and then try again. Make
sure you stand calmly and do not inter-
rupt the weighing process.
IB_KH5502_14_KOE5319_UK 06.07.2007 12:32 Uhr Seite 6
- 7 -
3. Place the cover back on the battery
compartment and press it down until
you hear it snap into place.
Use and Storage
Please take note that the measure-
ment results of different scales may
differ slightly.
Avoid using the batteries unnecessari-
ly. Therefore, do not store any items
on the scale if it is not being used.
Remove the batteries if you will not
use the scale for a longer period.
Keep the scale in a clean and dry envi-
ronment.
Avoid electrostatic charging.
Your glass scale represent a sensitive
electronic instrument. As such, high-
frequency devices may sometimes
cause disturbance when used in the
immediate vicinity (e.g. mobile tele-
phones, CB radio stations, remote
controls and microwave ovens).
If there are faults such as irregular or
faulty displays in the LCD display, remo-
ve the scale from the source of distur-
bance or deactivate the source of distur-
bance when you are using the product.
Replacing the Batteries
1. Remove the lid on the battery
compartment.
2. Remove the old batteries from the
battery compartment. Insert two new
batteries of type CR2032 into the
battery compartment. Be sure to
orient the batteries with the correct
polarity.
IB_KH5502_14_KOE5319_UK 06.07.2007 12:32 Uhr Seite 7
- 8 -
Cleaning
Only use neutral detergent and a soft
cloth to clean the glass scale.
Troubleshooting
Do not attempt to dismantle the scale to
repair any defects yourself. You may
otherwise damage the sensitive electro-
nic components.
Only qualified service personnel are au-
thorised to repair the glass scale!
No liability will be accepted for damage
resulting from improper use and/or ope-
ning of the appliance!
In the event of faulty operation or if the
display is incorrect, please check the fol-
lowing conditions:
Are the batteries positioned within
the battery compartment with the
correct polarity?
Is the selector switch (kg/lb) set to the
correct position?
Perform a reset on the scale:
To do this, remove the batteries from
the battery compartment.
Wait a few seconds, then insert the
batteries back into the battery
compartment.
If these measures do not correct the
problem, please contact the appropriate
service partner for your country.
Disposal
Do not dispose of the device in
normal domestic waste.
Dispose of the device over a registered
waste disposal firm or through your
communal waste disposal facility.
Observe the currently valid regulations.
In case of doubt, consult your waste
disposal facility.
Battery disposal!
Batteries may not be disposed of with
normal domestic waste. All consumers
are statutorily obliged to dispose of
batteries at the collection point in their
community/district or with the original
supplier.
The purpose of this obligation is to
ensure that batteries can be disposed
of in an environmentally-friendly man-
ner. Only dispose of batteries when
they are fully discharged.
Dispose of the packaging materi-
als in an environmentally respon-
sible manner.
Guarantee and service
Please see the accompanying leaflet for
the guarantee conditions and the service
address.
IB_KH5502_14_KOE5319_UK 06.07.2007 12:32 Uhr Seite 8
- 9 -
Importer
KOMPERNASS GMBH
BURGSTRASSE 21
D-44867 BOCHUM
www.kompernass.com
IB_KH5502_14_KOE5319_UK 06.07.2007 12:32 Uhr Seite 9
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13

Balance KH 5502 Operating Instructions Manual

Category
Personal scales
Type
Operating Instructions Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI