Drummond 56395 Owner's manual

Type
Owner's manual

This manual is also suitable for

Visit our website at: http://www.harborfreight.com
Email our technical support at: [email protected]
Do not return
pump to the store.
Call 1-844-416-9141
Owners Manual & Safety Instructions
Save This Manual Keep this manual for the safety warnings and precautions, assembly,
operating, inspection, maintenance and cleaning procedures. Write the product’s serial number in the
back of the manual near the assembly diagram (or month and year of purchase if product has no number).
Keep this manual and the receipt in a safe and dry place for future reference. 20c
When unpacking, make sure that the product is intact
and undamaged. If any parts are missing or broken,
please call 1-888-866-5797 as soon as possible.
Copyright
©
2019 by Harbor Freight Tools
®
. All rights reserved.
No portion of this manual or any artwork contained herein may be reproduced in
any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, actual product may differ slightly from the product described herein.
Tools required for assembly an d se rv ic e may n ot b e in cl uded.
Read this material before using this product.
Failure to do so can result in serious injury.
SAVE THIS MANUAL.
Page 2 For technical questions, please call 1-888-866-5797. Item 56395
Before start-up, note the following:
The pump must be connected to a GFCI protected plug which has been installed according
to regulations. The plug must have a supply voltage of 120 VAC at 60 Hz.
CAUTION
This pump has been evaluated for use with water only.
Page 3For technical questions, please call 1-888-866-5797.Item 56395
WARNING
IMPORTANT! For your own safety –
before starting to run the pump, please have
the following items checked by an expert:
1. Risk of electric shock – This pump is supplied
with a grounding conductor and grounding-type
attachment plug. To reduce the risk of electric shock,
be certain that it is connected only to a properly
grounded, grounding-type receptacle.
2. Risk of electric shock – This pump has not been
investigated for use in swimming pool areas.
3. The electrical connections must be
protected from moisture.
4. If there is danger of flooding, the electrical
connections must be taken to higher ground.
5. Circulation of caustic fluids, as well as the circulation
of abrasive materials, must be avoided at all costs.
6. The pump must be protected from frost.
7. The pump must be protected from running dry.
8. Access by children should also be
prevented with appropriate measures.
9. To prevent death from electric shock,
pump must be connected only to a
GFCI protected outlet.
10. Do not use an extension cord with this item.
11. Do not use a 3-to-2 prong power plug adapter.
Connect only to a properly-grounded
3 prong receptacle only.
12. People with pacemakers should consult their
physician(s) before use. Electromagnetic fields in
close proximity to heart pacemaker could cause
pacemaker interference or pacemaker failure.
13. The warnings, precautions, and instructions
discussed in this instruction manual cannot cover all
possible conditions and situations that may occur.
It must be understood by the operator that
common sense and caution are factors
which cannot be built into this product, but
must be supplied by the operator.
Fluid Type
The Pump is designed for use with water with a maximum temperature of 77° F (25°C). Do not use the pump
for other fluids, especially not fuels, cleaning fluids, or other chemical products.
Page 4 For technical questions, please call 1-888-866-5797. Item 56395
Specifications
Electrical Rating 120VAC / 60Hz / 10A
Power Cord Length 6’
Maximum Flow @ 0’ 950 GPH
Maximum Head lift @ 0 Flow 115.5′
Discharge Port 1″ NPT Thread
Installation
The pump must be installed in a stationary position with either:
a. A fixed pipeline or
b. A flexible hose pipe.
Please note!
1. Do not install the pump by suspending it
unsupported from its delivery pipe or power cord.
The pump must be suspended from the handle
or be placed on the bottom of the basin.
To ensure that the pump works properly, keep the
bottom free from sludge and dirt of all kinds.
2. If the water level sinks too low, any sludge in the
basin will dry out and stop the pump from starting.
To help ensure the pump will start as required,
check the pump regularly with start-up tests.
Power Supply
1. The pump is equipped with a shock-proof plug
according to regulations. The pump is designed to be
connected to 120 VAC, 60 Hz GFCI protected socket.
2. Make sure that the socket is sufficiently
secured and is in excellent condition.
3. When the plug is inserted into the socket,
the pump will be on standby.
4. WARNING: To prevent death from electric
shock, pump must be connected only
to a GFCI protected outlet.
WARNING! TO PREVENT SERIOUS INJURY:
If the power cord or plug is damaged, do not
use the pump. The power cord or plug may
only be repaired by a certified electrician.
Areas of use
1. This pump is designed to pump water only.
2. This pump is designed to be used for:
Pumping drinking water from shallow wells
and cisterns. Irrigation systems.
3. This pump should NOT be used for:
Continuous run, fountain/pond water
features. Water with dirt and debris.
4. This pump can also be used to transfer water
(e.g. household, farming, plumbing).
5. Do not use as a booster pump in a city water system.
Page 5For technical questions, please call 1-888-866-5797.Item 56395
Installation Instructions
This pump is designed for use as a well pump.
WARNING! TO PREVENT SERIOUS INJURY
FROM ELECTRIC SHOCK:
Install indoors or in weather-proof well house only.
This Pump is non-submersible.
Do not plug in the power cord when wet
or standing on damp or wet ground.
Do not plug in the power cord until instructed to do so.
NOTE:
a. ONLY pump clean water.
b. Additional components (such as valves and pipes)
may be required for installation, but not included.
c. Installation requires skilled workmanship
and compliance with local building codes.
If you are not confident in your ability to
properly and safely install this pump, have a
qualified technician perform the installation.
d. The water to be pumped must be clean and
must be free of sand and grit, which would
damage the pump and void the warranty.
1. The illustration below shows an example of a proper
shallow well pump installation. The total suction lift
(vertical well lift + length of off-set line) must
not exceed Maximum Suction Lift.
Foot
Valve
Check
Valve
Well
Seal
Shallow
Well Pump
To To
Household Household
Water Water
SystemSystem
Standing Water Level
(With Well Pump Off)
Pumping Water Level (with Well Pump Operating)
Outlet Water
Level
Vertical Well Lift
Head
SLOPE SLIGHTLY DOWNWARD TO WELL
Length of off-set lineLength of off-set line
(Add when calculating total
suction lift due to friction.)
Pump Setup Example
Note: This pump is intended for shallow well application
only and is not intended to be used as a booster pump.
Note: For optimal performance, install the pump
as close to the well head as possible.
2. Install a Foot Valve at the bottom of
the suction pipe. The Foot Valve must be
under the Pumping Water Level, the level that
the water falls to when the pump operates.
3. Install a sterile Well Seal at the top of the suction
pipe to keep the well clean. Protect from
rust inside a frost-proof enclosure.
4. Intake and discharge pipes must
be at least 1″ in diameter.
5. Lay an off-set line from the well to the structure
the pump will be installed in. The off-set
line should slope slightly towards the well.
Systems with longer off-set lines should use
larger diameter pipe to improve efficiency.
6. Install the pump on a rigid, level, dry platform.
This platform must provide a solid, level surface
that is capable of supporting the weight of
the pump and attached piping filled with water.
Do not allow water to contact the pump’s housing.
NOTICE: DO NOT INSERT fittings into the Intake
Hole farther than 1/2″; this can DAMAGE the Pump,
diminish Pump functions, and/or STOP water flow.
7. To prevent leaks, use metal fittings for all pipe
connections to pump ports. Do not use PVC fittings.
8. Keep the Head, the height that the pump
discharge must push water before discharge, to
a minimum. The Vertical Well Lift, Off-set Line
Length, and Head added together must be less
than Maximum Delivery Height to have flow at
output. Effective flow decreases to 0 GPH as
Maximum Delivery Height reaches its maximum.
9. For your protection, the power outlet used should
have a Ground Fault Circuit Interrupter (GFCI).
Have it installed by a qualified electrician.
Keep power line away from water.
10. The inlet and discharge lines should not be
wedged or stressed in a way that puts strain
on the pump. Do not support the pump
with the inlet or discharge lines.
Page 6 For technical questions, please call 1-888-866-5797. Item 56395
Operation
After reading these instructions, consider the following points before starting the pump:
1. The Compression Tank has a rubber bladder inside
that has been pressurized to 23 PSI. Remove
the cover over the air valve (on the tank end opposite
the pipe connection) and periodically monitor this
air valve with an air pressure gauge to ensure
that the rubber bladder maintains the required air
pressure. Air can be added using a bicycle pump.
2. Make sure the intake pipe is fully
submerged before continuing.
3. Before starting the pump for
the first time, prime it as follows:
a. Fill the suction Pipe and Pump Body
through the Priming Inlet.
b. Close the Inlet after verifying
that there are no leaks.
c. Open the spigots, faucets and/or taps
on the Delivery Pipe so that air can be
release from the suction cycle.
4. This is a self-starting pump that uses
a pressure switch. Once the power cord is
connected, the pump can start at any time.
Do not handle or perform maintenance on
the pump if the power cord is plugged in.
5. Verify that the pump rests on the floor of the basin,
if it is not suspended by the handle.
6. Verify that the discharge pipe is properly connected.
7. Verify that the electrical connection
is 120 VAC, 60 Hz.
8. Verify that the electrical socket is GFCI
protected and in good condition. Test
GFCI protected outlet before use.
9. Verify that water and moisture cannot
get near the power supply socket.
10. Verify that the pump is installed so
as to prevent running dry.
11. Run pump for two minutes. If it fails to pump
water, disconnect power, re-fill pump body
through priming inlet and re-start.
12. To begin pumping, plug in the power cord.
When the line is pressurized, the pump
will go to standby mode until the pressure
falls below its starting pressure.
Page 7For technical questions, please call 1-888-866-5797.Item 56395
Maintenance
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION:
Unplug the Pump from its electrical outlet before performing any
inspection, maintenance, or cleaning procedures.
If the pump is moved during operation, flush it out with clean water after every use.
Quarterly Maintenance
The below maintenance must be performed at least once every 3 months under optimal conditions.
For frequent use, or dirty areas, more frequent maintenance is required.
1. Clean the inlet screen on the intake port
regularly to remove accumulated debris.
2. Wipe the pump clean with a soft, damp cloth
with soapy water. Do not use solvents.
Do not get the electrical components wet.
3. Drain water from pump before storage by
disconnecting the water lines and turning the Pump
upside down. If storing the pump for a long time,
store it in a dry location, and apply a light layer of
oil to the metal parts prior to storage, to inhibit rust.
Do not expose to freezing temperatures.
4. After storage, check the Impeller to make
sure it turns easily and is not oxidized.
Page 8 For technical questions, please call 1-888-866-5797. Item 56395
Troubleshooting
Problem Cause Solution
The pump won’t start 1. No power.
2. Pressure switch disconnected.
3. Thermal Protection cut out.
4. Blocked impeller.
1. Check connections, and breaker/fuse.
2. Check gauge.
3. Allow pump to cool.
4. Free the impeller.
The pump operates
but it won’t
discharge water
1. Pump not primed.
2. Lift height exceeded.
3. Inlet tube not submerged.
4. Air in suction pipe.
5. Inlet screen clogged.
1. Prime pump.
2. Reduce lift height.
3. Submerge the inlet.
4. Check pipe and seals.
5. Clean screen.
Only a low volume
of water flows
1. Inlet pipe is too small.
2. Liquid is too dirty.
3. Lifting height exceeded.
4. Tank’s rubber bladder under-inflated.
5. Piping corroded, causing friction.
1. Increase pipe diameter.
2. Clean screen frequently.
3. Reduce lifting height.
4. Inflate to 23 PSI.
5. Replace rusted piping with
PVC where possible.
Motor overheats often Pump cycling too often. Cut-in and cut-out pressure may be set
too close together. Have the pressure
switch adjusted by a qualified technician.
Pump/motor
cycles rapidly
Cut-in and cut-out pressure
may be set too closely.
Have the pressure switch adjusted
by a qualified technician.
Tank bladder will
not hold pressure
1. Air inlet valve is leaking.
2. Bladder is broken.
1. Check air tank for leaks using soapy
water and replace bladder if needed.
2. Replace bladder.
Water pumps
intermittently
Water level is being drawn below foot valve. Lower foot valve.
Pump will not
hold prime
1. Foot/check valve not installed
in suction line.
2. Foot/check valve leaks water back to well.
1. Install foot and check valve in suction line.
2. Replace foot/check valve.
Water is full of
bubbles at outlet
1. Pumping bubbles temporarily as
air is purged after initial setup.
2. Leak in suction side of pump system.
3. Well is gaseous.
4. Water level below suction
inlet of foot valve.
1. Temporary self-remedying issue.
2. Check for and fix leaks.
3. Install a sleeve in the well.
4. Lower suction line into water
and re-prime. If water is deeper
than Maximum Suction Lift, then a
deep well pump may be needed.
Follow all safety precautions whenever diagnosing or servicing the pump.
Disconnect power supply before service.
Do not disassemble the pump or motor as this will damage the water seals.
All repairs should be performed by a qualified technician.
Page 9For technical questions, please call 1-888-866-5797.Item 56395
Problem Cause Solution
Motor runs, but water
is not pumping
1. Improper priming.
2. Air leakage.
3. Vertical lift too high.
4. Water level below suction inlet
of foot valve.
5. Frozen pipes.
6. Foot valve in dirt or sand.
7. Foot/check valve clogged.
8. Pressure switch is set too low.
1. Prime the pump by pouring clean
water into the Priming Inlet.
2. Check all pipes and joints in the suction
line for air leakage using soapy water.
3. Reduce vertical lift to within specifications.
See Installation on page 5
4. Lower suction line into water
and re-prime. If water is deeper
than Maximum Suction Lift, then a
deep well pump may be needed.
5. Thaw the pipes. Bury pipes below
freeze line/insulate pipes.
6. Raise foot valve to clean water level.
7. Clean or replace foot/check valve.
8. Have the pressure switch
adjusted by qualified technician
(30 PSI Start, 50 PSI Stop).
Pump does
not shut off
1. Pressure switch contacts welded together.
2. Fixture (toilet, faucet, etc.) open or leaking.
3. Impeller is clogged.
4. Tank bladder pressure is too low.
5. Pipeline leakage.
6. Foot/check valve leaks water back to well.
1. Have the pressure switch replaced
by a qualified technician.
2. Close or repair fixture.
3. Clean impeller.
4. Inflate to 23 PSI.
5. Repair pipeline.
6. Replace foot/check valve.
Follow all safety precautions whenever diagnosing or servicing the pump.
Disconnect power supply before service.
Do not disassemble the pump or motor as this will damage the water seals.
All repairs should be performed by a qualified technician.
Page 10 For technical questions, please call 1-888-866-5797. Item 56395
Parts List and Diagram
PLEASE READ THE FOLLOWING CAREFULLY
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM
IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR
MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS
QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE
ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY
STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND
LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY
ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS
THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.
Parts List
Part Description Qty.
1 Plug and Cable 1
2 Pressure Switch 1
3 Pressure Gauge 1
4 Dust Cover 1
5 Screw 8
6 O-Ring 1
7 Dust Cover 1
8 Screw 1
9 Pump Body 1
10 O-Ring 1
11 Guiding Object 1
12 Nut 1
13 Impeller 1
14 O-Ring 1
15 Flange 1
16 Water Proof Ring 1
17 Bolt 4
18 Terminal Box 1
19 Seal 1
20 Capacitor 1
21 Bolt 2
22 Block 1
23 Bottom Cover 1
Part Description Qty.
24 Bolt 4
25 Seal 1
26 Aluminum Front Cover 1
27 Ball Bearing 2
28 Support 1
29 Bolt 4
30 Gasket 2
31 Nut 4
32 Flexible Tube 1
33 Gasket 1
34 Tank 1
35 Sheath 1
36 Rotor 1
37 Cable 1
38 Gasket 1
39 Stator 1
40 Motor Box 1
41 Aluminum Cover 1
42 Bolt 4
43 Fan 1
44 Circlip 1
45 Bolt 4
46 Fan Cover 1
Record Product’s Serial Number Here:
Note: If product has no serial number, record month and year of purchase instead.
Note: Some parts are listed and shown for illustration purposes only,
and are not available individually as replacement parts.
Page 11For technical questions, please call 1-888-866-5797.Item 56395
Assembly Diagram
1 2 3 4
5
6
7
8
9 10 11 12
16
17
18
19
20
21
22
24
23
25
28
29
26
27
30
13
31
14
15
32
33 34
35 36
37 38 39
40 41 42 43 44
45 46
Limited 90 Day Warranty
Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards,
and warrants to the original purchaser that this product is free from defects in materials and workmanship for the
period of 90 days from the date of purchase. This warranty does not apply to damage due directly or indirectly,
to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, criminal activity, improper
installation, normal wear and tear, or to lack of maintenance. We shall in no event be liable for death, injuries
to persons or property, or for incidental, contingent, special or consequential damages arising from the use of
our product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the
above limitation of exclusion may not apply to you. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS.
To take advantage of this warranty, the product or part must be returned to us with transportation charges
prepaid. Proof of purchase date and an explanation of the complaint must accompany the merchandise.
If our inspection verifies the defect, we will either repair or replace the product at our election or we may
elect to refund the purchase price if we cannot readily and quickly provide you with a replacement. We will
return repaired products at our expense, but if we determine there is no defect, or that the defect resulted
from causes not within the scope of our warranty, then you must bear the cost of returning the product.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
26541 Agoura Road • Calabasas, CA 91302 • 1-888-866-5797
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Drummond 56395 Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI