HIITMill & HIITMill X
ASSEMBLY INSTRUCTIONS
For Installation assistance or missing parts, please call CORE Health & Fitness at 1(800) 503-1221Document # 620-8596 Rev. C
PAGE 2 OF 2
STEP 2:
Use a 3mm allen key to secure the HIIT
Console to the mount using four (4) M5 x 14mm screws.
STEP 3: Connect the main data cable to the console.
STEP 4: After installing the console, ensure that the unit type
is set for the appropriate model:
1. Power the console on by pressing the counter-clockwise
arrow.
2. Press and hold the arrow up, arrow down, and clock
buttons at the same time for 3-5 seconds.
3. Verify that the “tread” software is selected. To do this, use
the down arrow to navigate to the 4th page and press the
clock button to change between the following:
P1 “tread” - HIITMill and HIITMill X
P2 “bic1” - HIIT Bike
P3 “ergo” - HIIT UBE
P4 "Step" - Not Used Currently
P5 “bic2” - Airfit Bike
P6 none - Not Used Currently
4. Press the back button located between the up/down arrow
buttons to return to the main workout screen once “P1 -
tread” has been selected.
STEP 5: Calibrating HIITMill (X) Power Sensor:
Before using the HIITMill with the HIIT Console installed, the
power sensor must be calibrated. If the sensor is not calibrat-
ed before using the unit, the console will display inaccurate
workout data. The calibration should only need to be done
during the first setup. The calibration can also be done to
correct any perceived issues with the workout data not being
accurate.
1. Push the brake adjustment lever all the way forward (away
from the user).
2. Press and hold the arrow up, arrow down, and clock
buttons at the same time for 3-5 seconds.
3. Use the down arrow to navigate to page 7, then push the
clock button to set the zero-point angle.
4. Press the back button located between the up/down arrow
buttons to return to the main workout screen.
STEP 1: Use a #2 phillips screwdriver to remove the
locking screw securing the battery drawer inside
the console. Remove the battery drawer then install two
(2) LR14 1.5V batteries into the drawer. Finally, reinsert
the battery drawer and reinstall the locking screw.