Frigidaire R6GI Product information

Type
Product information

This manual is also suitable for

WIRING DIAGRAM
Line Voltage 208/230 VACR6GI/PPG2GI - 5 Ton Package Gas/Electric 1 Phase / 60 Hz
NOTES:
1. Disconnect all power before servicing.
2. For supply connections use copper conductors only.
3. Not suitable on systems that exceed 150 volts to ground.
4. For replacement wires use conductors suitable for 105 deg.C.
5. For ampacities and overcurrent protection, see unit rating plate.
6. For 208-230V Models only. For 208V operation remove wire from
230V tap and place on 208V tap.
1. Couper le courant avant de faire letretien.
2. Employez uniquement des conducteurs en cuivre.
3. Ne convient pas aux installations de plus de 150
volt a la terre.
7. For 208V operation, inducer motor low speed resistor must be
by-passed. Remove red wire from resistor block and connect to
piggyback terminal on opposite side.
8. Ferrite chokes are shown by an ellipse enclosing wires. The number
of turns per wire through the choke is shown by , for example.
2X
FIELD WIRING
LEGEND:
LOW VOLTAGE
HIGH VOLTAGE
HPS - HIGH PRESSURE SWITCH
LPS - LOW PRESSURE SWITCH
711074B
(Replaces 711074A)
04/13
Y2
E
O
Y1
W2
G
C L W1
R
COM
230
24V
208
INDUCER
MOTOR
IGNITOR
FRESH AIR
DAMPER
FLAME
SENSOR
2 STAGE
GAS
VALVE
RESISTOR
TERMINAL
BLOCK
INDOOR
BLOWER
MOTOR
HIGH
TEMP
LIMIT
FLAME
ROLL-OUT
LIMIT
HPS
11
4
1
8
7
10
5
2
9
3
12
6
LINE- N
XMFR-N
LINE
LINE
XMFR
EAC
HUM
LINE- N
1 432 5
R
C
TX
RX
W
COM
G
C R
W1
W2
Y/Y2
Y1
BLWR OFF
DELAY
GAS
CONTROL
COM
HIGH
LOW
GNDSEN
DHUM
Y1
H
L2-OUT
L2-IN
L1
L1
Y1Y/Y2W
CR
HP
SPEED
COMMON
PWM
MODE
OPEN
OPEN
FAULT
R
C
RX
GRD
TX
W
C
DX-
DX+
R
RED
GREEN
COOL
FAN SPEED
HEAT
BLOWER CONTROL
BOARD
1 2 3
1 2 3
1 2 3
1 2
1 2
HPS
LPS
RED
BLACK
YELLOW
BLUE
L2L1ACLACNPEP2P1UVW
INTERFACE
BOARD
OUTDOOR TEMP
COIL TEMP #1 COIL TEMP #2
SUCTION TEMP
SUCTION PRESSURE EXV DRIVER
LPS
DISCHARGE TEMP
PWM FAN
CONTROL
COMPRESSOR
TO 208/230-1-60
POWER SUPPLY
REACTOR
L1
GND
L2
W
AC
OUT
T2
L2
T1
L1
POWER
LINE
FILTER
TERMINAL BLOCK
CONTACTOR
RELAY
N
N
L
V
U
BLACK
BLUE
RED
YELLOW
BLUE
RED
WHITE
AC
IN
L
BK
TERMINAL
BLOCK
PTC
A1
A2
L1
T1
L2
T2
BROWN
1
7
8
9
4
3
2
5
6
YELLOWYELLOW
BLACK
TERMINAL
BLOCK
1
2
3
4
5
6
7
BLACK
RED
BLACK
RED
BLACK
RED
RED
RED
BROWN
BLOWER
HARNESS
OUTDOOR
FAN MOTOR
8X
2X
8X
GREEN
BLACK
BROWN
OUTDOOR
TEMP
EXV
MOTOR
DISCHARGE
TEMP
COIL
TEMP #2
LOW PRESSURE
SWITCH
SUCTION
PRESSURE
SUCTION
TEMP
1X
50A
4X
1X 1X
4X
2X
WU
V
COMPRESSOR SHELL
(TOP VIEW)
4X
WHITE
BLACK
4X
4X
4X
GREEN
COVER
POST
RED
RED
BLUE
BLUE
WH
BROWN
GREEN
WHITE
RED
RED
RED
RED
RED
GREEN
BLUE
BLUE BLUE
ORANGE
ORANGE
BLACK
BLACK
BLACK
BLACK
YELLOW
YELLOW
YELLOW
BROWN
BROWN
BROWN
VIOLET
VIOLET
WHITE
BLUE
RED
BLACK
WHITE
BROWN
BLACK
RED
WHITE
BROWN
BLACK
YELLOW
GREEN
BLACK
WHITE
RED
BLACK
BLACK
RED
YELLOW
BK/WH STRIPE
GRAY
GREEN
BLACK
GREEN
WHITE
YELLOW
RED
RED
BLACK
GREEN
BLUE
ORANGE
WHITE
YELLOW
RED
BLACK
SHIELDING
FIELD LOW
VOLTAGE
CONNECTIONS
SEE NOTE 6
SEE
NOTE 7
  • Page 1 1

Frigidaire R6GI Product information

Type
Product information
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI