Heavy-DutyCommercialGas
Tankless Water Heaters
September 2013 Page 2of2
www.hotwatercanada.ca CANCG14000
ForTechnical Information call 1-888-479-8324.A.O. Smith Corporationreserves theright to make product changes or improvements withoutprior notice.
TANKLESS HEAVY-DUTY COMMERICAL MODELS
8-7/8” (226mm)
4-1/2” (114mm)
18-1/2” (470mm)
15-3/4” (399mm)
7” (179mm)
)mm626(”8/5-42
)mm006(”8/5-32
1-1/2” (40.9mm) COLD
5-7/8” (147mm) GAS
1-5/8” (42mm) 120v
5-7/8” (149mm)HOT
1-1/8” (27.8mm)
3-1/8” (80.8mm)
4-5/8” (118.3mm)
6-1/4” (159mm)
All dimensions are in inches.
15-150 psi water pressure. 40 psi or above recommended for maximum flow.
* ASME models
**Current numbers based on factory testing, 0.4 GPM required for continuousfireafter initial ignition.
***Category III required
Pressureonly relief valve requires (Min.240,000 BTUs. 150 PSI).
CLEARANCES:
Top 12”, Bottom 12”, Front 24”, Back 1”, Sides 2”
10.0
9.0
8.0
7.0
6.0
5.0
4.0
3.0
2.0
1.0
0.0
020406080100 120 140
Flow Rate Vs. TemperatureRise
Flow Rate (gpm)
Temperature Rise (°F)
10.08.06.04.02.00.0
0
20
40
60
15
30
25
0
10
10
20
30
50
Flow Rate (gpm)
Pressure Loss (psi)
Head Feet
Above shown rate is basedon single unit only
Pressure Drop
5
Set temperature of 145° or lower Set temperatureof 150°orhigher
Set temperature of 145° or Lower Set temperature of 150° or higher
MODEL
NUMBER
FUEL
TYPE
GASCONSUMPTION
INPUT
THERMAL
EFFICIENCY
INLET GAS
PRESSURE
GPM**
DIMENSIONS
(INCHES)
VOLT AMP FLUE***
INTAKE
(OPTIONAL)
HOT/COLD
GASCONN.
APPROX.
SHIPPING
WEIGHT
(LBS)
MIN.
BTU/H
MAX.
BTU/H
MIN.
W.C.
MAX.
W.C.
HEIGHT WIDTH DEPTH
ATIO-710-N Natural 24,000 240,000 82%5.0 10.5 0.5-9.0120 0.94 4” O.D. 4” O.D. 3/4” NPT66
ATIO-710-P Propane 24,000 240,00084% 8.014.00.5 - 9.0 120 0.944”O.D.4”O.D.3/4 ”NPT 66
ATIO-710-AN*Natural 24,000 240,00082% 5.010.50.5 -9.0 1200.944”O.D.4”O.D.3/4 ”NPT 66
ATIO-710-AP* Propane 24,000 240,000 84% 8.014.00.5 - 9.0 23-5/818-1/2 8-7/8120 0.944”O.D.4”O.D.3/4 ”NPT 66
Specification
Waterheater(s) shall be Model _________________ as manufactured by A. O. Smith. Thewater heater(s)shall be acoppercoilintegral finand tube construction with quick releasebrass or
bronze waterways. Heater(s) willbe factory assembled and tested. Theheatershall be vented with 4” Stainless steel CategoryIII vent pipe adistance nottoexceed 50’(equivalent) feet
terminating vertically or horizontally as prescribed. Intake air with optional direct vent kit may be of such material as ULC s636 PVC or CPVC, galvanized B-Vent, corrugated aluminum or
stainless steel or Category IV stainless steelnot to exceed a total of 50’ (equivalent). The heater(s) shall be controlled by onboard solid state printed circuit board monitoring incoming and
outgoing temperatures with factory-installed thermistors, sensing and controlling flow rate to set point temperature with control both air and gas mixture inputs to maintain thermal
combustion efficiency. Unit also consists of ground fault interrupter, inline fusing, spark ignition and sensor system, aluminized stainless steel burners, air-fuel ratio rod, Hi limit switch,
modulating and proportional gas valves, freeze protection sensor and heating blocks and overheat cutoff fuses. The water heater(s) shall be CSA listed, meets the energy efficiency
requirements of ASHRAE 90. 1b-1992.
23-5/818-1/2 8-7/8
23-5/818-1/2 8-7/8
23-5/818-1/2 8-7/8