Symmons S-4404 Installation guide

Category
Sanitary ware
Type
Installation guide
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 (800)796-6667 Fax: (800)961-9621
©2014 Symmons Industries, Inc.
www.symmons.com
ZV-3073 REV 0 09/18/14
S-4404-TRM
Carrington
Tub/Hand Shower Trim
Operation & Maintenance Manual
Model Numbers Specifications
S-4404-TRM Tub/Hand Shower Trim
Tub/hand shower trim with lever handle and secondary
integral diverter handle includes wall connection, cradle
for hand shower mounting, non-diverter tub spout,
in-line vacuum breaker, exible metal hose and 3 mode
hand shower with 2.5 gpm (9.5 L/min) ow restrictor.
Components made from metal and nonmetallic materials
plated in standard polished chrome nish.
Modifications Warranty
-1.5 1.5 gpm (5.7 L/min) flow restrictor
-2.0 2.0 gpm (7.6 L/min) flow restrictor
-442HSB 30" slide bar in place of wall cradle on
hand shower units
-CRP Cross handle in place of white
insert handle
-LAM Metal finish insert handle
-STN Satin nickel finish
Limited Lifetime - to the original end purchaser in
consumer installations.
5 Years - for commercial installations.
Refer to www.symmons.com/warranty for complete
warranty information.
Note: Append appropriate -sufx to model number.
2
Dimensions
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 (800)796-6667 Fax: (800)961-9621
©2014 Symmons Industries, Inc.
www.symmons.com
ZV-3073 REV 0 09/18/14
Measurements
A 2 1/8", 53 mm
B
Male 1/2" IPS thread must
be recessed 1/4" from
nished wall
C Ø 7 1/2", 191 mm
D 3 1/8", 79 mm
E Ø 2 5/8", 67 mm
F 32", 813 mm
G 12", 305 mm
H 3 1/8", 79 mm
I 2 3/4", 70 mm
J
(Rough in)
2" ± 1/2", 51 mm ± 13 mm
K 1/2" NPT
L 1/2", 13 mm
M 6 1/2", 165 mm
Notes:
1) All dimensions measured from nominal rough-in (see J as reference).
2) Dimensions are subject to change without notice.
AA
C
C
E
E
F
F
G
G
B
B
H
H
I
I
J
J
M
M
L
L
K
K
Floor
Floor
D
D
3
Parts Breakdown
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 (800)796-6667 Fax: (800)961-9621
©2014 Symmons Industries, Inc.
www.symmons.com
ZV-3073 REV 0 09/18/14
Replacement Parts
Item Description Part Number
A
S
Vacuum Breaker
60" Hose
EF-104
B Wall Elbow EF-105
C
D
E
F
Set Screw
Handle
Flange
O-ring
DF-28-LPO
G Lock Nut T-20-PL
H Washer 40B-PL
I
L
Mounting Screws
Escutcheon
DF-14-SL
J Dome Cover DF-11
K Escutcheon Plate 7.5-ETCH
M
N
O
Cradle Mounting Screws
Cradle
Cradle Mounting Plate
EF-106
P Diverter Handle DF-21/22
Q Tub Spout 063
R Hand Shower 442W
Notes:
1) Append -STN to part number for satin nickel nish.
2) Append -1.5 or -2.0 to showerhead or hand shower
for low ow.
Required for Installation
Adjustable wrench
Phillips head screwdriver
Allen wrench (1/8")
Plumber tape
R
I
A
B
L
S
M
O
C
E
G
D
F
H
P
N
Q
J
K
4
Installation
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 (800)796-6667 Fax: (800)961-9621
©2014 Symmons Industries, Inc.
www.symmons.com
ZV-3073 REV 0 09/18/14
Note:
For valve body installation, please
see valve body installation guide.
1) Install secondary integral
diverter handle (P) into shower
escutcheon (L).
2) I
nstall shower escutcheon plate (K)
and shower escutcheon (L) to shower
valve. Secure with two screws (I).
3) Install dome cover (J) and
washer (H) to valve and secure
with lock nut (G).
4) Install o-ring (F), ange (E), and
handle (D) to valve and secure
with screw (C).
Note: Handle should be facing the
6 o'clock position.
5) Install tub spout (Q) to pipe
tting. Turn clockwise to secure.
6) Install wall elbow (B) to pipe
tting. Turn clockwise to tighten.
L
P
1
2
3
I
K
L
1
2
J
G
H
1
2
B
1
2
C
E
D
F
1
2
Q
5
7) Place mounting plate
(O)
in
position, mark and drill 1/8" pilot
holes into stud.
Option:
Place mounting plate
(O)
in
position, mark and drill 3/16" holes
into wall. Install anchors.
8) Remove cover of hand shower
cradle
(N)
. Install cradle and
mounting plate
(O)
. Secure with
three screws
(M)
. Replace cover
on hand shower cradle.
9)
Attach large end of hand shower
hose (S) to hand shower (R).
Attach small end of hand shower
hose (S) and gasket to in-line
vacuum breaker (A). Connect
in-line vacuum breaker to wall
elbow (B). Turn clockwise to
tighten.
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 (800)796-6667 Fax: (800)961-9621
©2014 Symmons Industries, Inc.
www.symmons.com
ZV-3073 REV 0 09/18/14
1
3
2
O
3
1
4
2
S
R
A
S
B
4
3
O
M
N
2
1
1
2
O
Installation
6
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 (800)796-6667 Fax: (800)961-9621
©2014 Symmons Industries, Inc.
www.symmons.com
ZV-3073 REV 0 09/18/14
Care and Cleaning
1) Clean nished trim area with a soft cloth using mild soap and water or a non-abrasive cleaner and then quickly rinse
with water.
Troubleshooting Chart
Problem Cause Solution
Finish is spotting. Elements in water supply may cause
water staining on nish.
Clean nished trim area with a soft
cloth using mild soap and water or a
non-abrasive cleaner and then
quickly rinse with water.
Operation
Temperature Control Diverter Control
1) Turn shower handle counterclockwise approximately
1/4 turn to put valve in cold position.
2) Turn shower handle counterclockwise approximately
1/2 turn to put valve in warm position.
3) Turn shower handle counterclockwise approximately
3/4 turn to put valve in hot position.
1) Turn diverter left for tub spout operation.
2) Turn diverter right for hand shower operation.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Symmons S-4404 Installation guide

Category
Sanitary ware
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI