  • Hello! I am an AI chatbot trained to assist you with the Mitsubishi Electric CC-Link UNIT MR-J2S-T01 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
CC-Link UNIT
MR-J2S-T01
Installation Guide
B
MITSUBISHI ELECTRIC CORPORATION
HEAD OFFICE: TOKYO BLDG MARUNOUCHI TOKYO 100-8310
This installation guide uses recycled paper.
IB(NA)0300048-B(1104)MEE Printed in Japan Specifications are subject to change without notice. Created April, 2011
General-Purpose AC Servo
1. SPECIFICATIONS
Item
Type
MR-J2S-T01
Applicable CPU card QnA(H), QnAS(H), A1S, A1SH, AnUS(H), AnN, AnA, AnU(H)
Communication speed 10M/5M/2.5M/625k/156kbps
Communication system Broadcast polling system
Synchronization system Frame synchronization system
Transmission path format Bus format (conforming to EIA RS485)
Transmission format Conforming to HDLC
Remote station number 1 to 64
Communication speed 156k to 10Mbps
Overall distance 1200 to 50m (3934.426 to 163.934ft.)
Between master/local
station and preceding/
subsequent station
2m (6.557ft.) or more
(Note) Max.
transmission
distance
Distance
between
stations
Between remote I/O
stations/remote device
stations
30cm (0.984ft.) or more (depends on communication speed)
Error control system CRC
PLC side master station
Connection cable Twisted pair cable (3-wire type)
Number of servo amplifiers connected
Up to 42 amplifiers only as remote device station
(when 1 station is occupied per amplifier),
(up to 32 amplifiers when 2 stations are occupied per amplifier)
Can be shared with other device
[ ] 0 to 55 (non-freezing)
In operation
[
] 32 to 131 (non-freezing)
[ ] 20 to 65 (non-freezing)
Ambient temperature
In storage
[
] 4 to 149 (non-freezing)
In operation
Ambient humidity
In storage
90%RH or less (non-condensing)
Ambience
Indoors (no direct sunlight),
Free from corrosive gas, flammable gas, oil mist, dust and dirt
[m/s
2
] 5.9 or less
Environment
Vibration
[ft/s
2
] 19.4 or less
Mass 0.3kg (0.66lb)
Note. Depends on the cable used. For more information, refer to the CC-Link system master/local module user's manual.
156(6.14)
C
N
4
0
SD
RD
WD
C
N
3
0
1
2
S
W
1
2
3
R
S
W
C
N
1
0
6
135(5.32)70(2.76)
NAME
PLATE
2- 6(0.24)Mounting hole
25(0.98)
6
66
168(6.61)
(0.24)
(0.24)
(0.24)
Module screw
tightening torque
2.5[N m]
(354.0[oz in])
[Unit: mm(in)]
Mass: 0.3kg(0.66lb)
(0.24)
2. OUTLINE DRAWING
/