Marantec EM 130 is a two-way traffic control expansion module for the Control x.plus control unit. It enables automatic closing and prioritizes entry or exit through continuous green light for the selected direction. Additional features include adjustable door open duration, warning time, and the option for automatic alternating operation. The EM 130 also provides connections for signaling devices and external control elements.

Marantec EM 130 is a two-way traffic control expansion module for the Control x.plus control unit. It enables automatic closing and prioritizes entry or exit through continuous green light for the selected direction. Additional features include adjustable door open duration, warning time, and the option for automatic alternating operation. The EM 130 also provides connections for signaling devices and external control elements.

Expansion module EM 130
Two-way traffic control for Control x.plus
Manual for installation and operation
GB
2 Manual for installation and operation, Expansion module EM 130 GB (#96650)
2. Table of contents
Caution!
Danger of personal injury!
The following safety advice must be
observed at all times so as to avoid
personal injury!
Attention!
Danger of material damage!
The following safety advice must be
observed at all times so as to avoid
material damage!
Advice / Tip
Check
Reference
i
Advice
1. Meaning of symbols . . . . . . . . . .2
2. Table of contents . . . . . . . . . . . .2
3. General safety advice . . . . . . . . .3
4. Product overview . . . . . . . . . . . .5
5. Installation . . . . . . . . . . . . . . . . .5
5.1 Install expansion module . . . . .5
5.2 Wiring of the expansion
module . . . . . . . . . . . . . . . . . .6
6. Programming . . . . . . . . . . . . . .10
1. Meaning of symbols
Manual for installation and operation, Expansion module EM 130 GB (#96650) 3
3. General safety advice
Target group
This product may only be installed, connected and put into operation by qualified and trained professionals!
Qualified and trained specialist personnel are persons
- who have knowledge of the general and special safety regulations,
- who have knowledge of the relevant electro-technical regulations,
- with training in the use and maintenance of suitable safety equipment,
- who are sufficiently trained and supervised by qualified electricians,
- who are able to recognise the particular hazards involved when working with electricity,
- with knowledge regarding applications of the EN 12635 standard (installation and usage requirements).
Warranty
For an operations and safety warranty, the advice in this instruction manual has to be observed.
Disregarding these warnings may lead to personal injury or material damage. If this advice is disregarded,
the manufacturer will not be liable for damages that might occur.
To avoid installation errors and damage to the device, it is imperative that the installation instructions are
followed. The product may only be operated after reading these installation and operating instructions.
The installation and operating instructions are to be given to the door system user, who must keep them
safe. They contain important advice for operation, checks and maintenance.
This item is produced according to the directives and standards mentioned in the Manufacturer's
Declaration and in the Declaration of Conformity. The product has left the factory in perfect condition with
regard to safety.
Power-operated windows, doors and gates must be checked by an expert (and this must be documented)
before they are put into operation and thereafter as required, but at least once a year.
Correct use
The expansion module expands the Control x.plus control unit to include a two-way traffic control
function.
Beside the advice in these instructions, please observe the general safety and accident
prevention regulations!
Our sales and supply terms and conditions are effective.
Please read carefully!
3. General safety advice
Installation tips
• Ensure that the devices to be connected (doors etc.) are in a mechanically faultless state.
• Before commencing cabling works it is very important to disconnect the system from the electricity supply.
Ensure that the electricity supply remains disconnected throughout the cabling works.
• Adhere to the local protection regulations.
• Lay the electricity supply cables and control cables; these MUST be laid separately.
The operating voltage is 24 V.
Information on cleaning the operator system
Never use water jets, high pressure cleaners, acids or bases for cleaning.
Please read carefully !
4 Manual for installation and operation, Expansion module EM 130 GB (#96650)
Manual for installation and operation, Expansion module EM 130 GB (#96650) 5
Supply package
Dimensions
1 Expansion module
2 Cable harness for module connection
1
4.1 / 1
2
4.1 / 2
126
46
85
5.1 Install expansion module
• Fit the expansion module (B) in the type 4 /
type 5 (A) expansion housing type.
5.1 / 1
A
B
5. Installation4. Product overview
A
5. Installation
6 Manual for installation and operation, Expansion module EM 130 GB (#96650)
Designation
Type / function
i
A Operating indicator
B Display for output XH19B
C Display for output XH19A
D
Display for control
element activated
E Exit display RED
F Exit display GREEN
G Entry display RED
H Entry display GREEN
XB41A
Connection of
Control x.plus control unit
5.2.2 / 1
XB41B
Connection of further
module
5.2.2 / 1
XB50
Connection of supply for
external control elements
24 V DC, max. 100 mA
5.2.2 / 4
XB53A
Connection of entry / exit
impulse button
5.2.2 / 2
XB59
Connection of further
control elements
5.2.2 / 3
XH13
Connection of entry / exit
signalling device
5.2.2 / 7
XH19A
Connection of signalling
device
5.2.2 / 5
XH19B
Connection of signalling
device
5.2.2 / 6
5.2 Wiring of the expansion
module
5.2.1 Overview of the module connections
5.2.1 / 1
B
C
D
XB59
XB41A
XH13
XH19A
XH19B
XB41BXB53A
XB50
H
G
F
E
Advice:
The “control element activated”
display (D) does not light up when
switches SB 31, SB 32 and SB 35 are
closed. All other control elements at
terminals XV53A, SB53B and SB59
are only indicated at display (D) and
do not light up the LED display 7 on
the lid of the Control x.plus.
Manual for installation and operation, Expansion module EM 130 GB (#96650) 7
5. Installation
5.2.2 Connection of the modules
• Connect the Control x.plus control unit to the
connecting socket XB41A.
• Connect another module to socket XB41B as
required.
5.2.2 / 1
XB41B
Connection of the control unit and a further
module
5.2.2 / 2
Connection of entry / exit button (XB53A)
M09E029
XB41A
Designation
Type / function
SB36 Entry button
SB37 Exit button
Supply of external control elements, 24V DC,
max. 100mA (XB50)
-XB50
+-
+2
4
VDC
GND
5.2.2 / 4
M09E029
Designation
Type / function
HH94 Signal light supplied by customer
XH19A Connection of signalling device
Connection of signalling device (XH19A)
5.2.2 / 5
M09E028
92
94
H1
Attention!
To avoid damage being caused to the
circuit board, the contact loading
(max. 230 V / 0.5 A) must be
observed.
Reference:
The programming of the signalling
device XH19A is described in the
Control x.plus documentation
(Level 3 / Menu 7).
i
5. Installation
8 Manual for installation and operation, Expansion module EM 130 GB (#96650)
Designation
Type / function
SB31
Switching contact for entry / exit
priority function
SB32
Switching contact for energy
saving function
SB35
Switching contact for
automatic OFF
SB47 CLOSE master button
Connection of further control elements
(XB59)
5.2.2 / 3
M09E029
Manual for installation and operation, Expansion module EM 130 GB (#96650) 9
5. Installation
Connection of signalling device (XH19B)
5.2.2 / 6
M09E028
92
94
H1
Reference:
Programming the signalling device
XH19B is described in Section 6
(Level 3 / Menu 8).
i
Connection of entry / exit signalling device
(XH13)
5.2.2 / 7
M09E028
Designation
Type / function
HH36A Entry signal light RED
HH36B Entry signal light GREEN
HH37A Exit signal light RED
HH37B Exit signal light GREEN
XH13 Connection of signalling device
Designation
Type / function
HH94 Signal light supplied by customer
XH19A Connection of signalling device
6. Programming
Level 3 - Automatic closing timer / two-way traffic control
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Menu 2: Two-way traffic control function sequence
A2 B2 C2 D2 E2 F2 G2 H2 I2 J2 - - - - - -
Menu 3: Door open duration / green phase (in seconds)
OFF 5 10 15 20 25 30 35 40 50 80 100 120 150 180 255
Menu 4: Warning time / red phase (in seconds)
OFF 2 5 10 15 20 25 30 35 40 45 50 55 60 65 70
Menu 6: Entry / exit green and red phase
A6 B6 C6 - - - - - - - - - - - -
Menu 8: Expansion module relay output
A8 B8 C8 D8 - - - - - - - - - - - -
An activated module changes Level 3 and results in the following menus being activated:
Legend:
LED off
LED on
LED flashes slowly
LED pulses
LED flashes quickly
Factory default setting
Not possible
10 Manual for installation and operation, Expansion module EM 130 GB (#96650)
Menu 2: Two-way traffic control function
The operating mode and function of the automatic closing timer / two-way traffic control
expansion module is set here.
Stage Operating mode
Automatic OFF
(SB 35)
Priority function
(SB31)
Photocell/closing
prevention device
(SB34)
A2
Normal operation
with restart of green
phase
Switching contact
open: Door closes
automatically after
times have expired
Switching contact
closed:
Door does not close
automatically after
times have expired
Switching contact
open: Two-way
traffic control func-
tion (traffic lights in
push-pull operation)
Switching contact
closed: Automatic
closing timer func-
tion (traffic lights in
push-push operation)
Green phase / door
open duration is
restarted after the
vehicle has driven
through the closing
prevention device /
photocell.
B2
Normal operation
with interruption of
green phase
Green phase / door
open duration is
ended after the
vehicle has driven
through the closing
prevention device /
photocell.
C2
Normal operation
without influencing
the times
No influence on
times
D2
Priority for entry or
exit through continu-
ous green for the
side concerned
Switching contact
open: Priority func-
tion switched off
(operation as in C2)
Switching contact
closed: Priority func-
tion through contin-
uous green
Switching contact
open: Continuous
green for exit
Switching contact
closed: Continuous
green for entry
6. Programming
Manual for installation and operation, Expansion module EM 130 GB (#96650) 11
6. Programming
Stage Operating mode
Automatic OFF
(SB 35)
Priority function
(SB31)
Photocell/closing
prevention device
(SB34)
E2
Automatic alterna-
tion of green phase
for entry and exit
Switching contact
open: automatic
alternating operation
switched off (opera-
tion as in C2)
Switching contact
open: Two-way traf-
fic control function
(traffic lights in push-
pull operation)
Switching contact
closed: Automatic
closing timer func-
tion (traffic lights in
push-push operation)
No influence on
times
Switching contact
closed: automatic
alternating operation
No influence on the
function
F2:
Normal operation
with restart of green
phase, with start
impulse
Switching contact
open: Door closes
automatically after
times have expired
Switching contact
closed:
Door does not close
automatically after
times have expired
Start impulse for
opening the door
when switching
contact is closed
Switching contact
open: Two-way
traffic control func-
tion (traffic lights in
push-pull operation)
Switching contact
closed: Automatic
closing timer func-
tion (traffic lights in
push-push operation)
Green phase / door
open duration is
restarted after the
vehicle has driven
through the closing
prevention device /
photocell.
G2
Normal operation
with interruption of
green phase, with
start impulse
Green phase / door
open duration is
ended after the
vehicle has driven
through the closing
prevention device /
photocell.
H2
Normal operation
without influencing
the times, with start
impulse
No influence on
times
12 Manual for installation and operation, Expansion module EM 130 GB (#96650)
Stage Operating mode
Automatic OFF
(SB 35)
Priority function
(SB31)
Photocell/closing
prevention device
(SB34)
I2
Priority for entry or
exit through continu-
ous green for the
side concerned,
with start impulse
Switching contact
open: Priority func-
tion switched off
(operation as in H2)
Switching contact
open: Two-way
traffic control
function (traffic
lights in push-pull
operation)
Switching contact
closed: Automatic
closing timer func-
tion (traffic lights in
push-push operation)
No influence on
times
Switching contact
closed: Priority
function through
continuous green
Start impulse for
opening the door
when switching
contact is closed
Switching contact
open: Continuous
green for exit
Switching contact
closed: Continuous
green for entry
6. Programming
Manual for installation and operation, Expansion module EM 130 GB (#96650) 13
Advice:
Input SB32 is equipped with an energy saving function.
- Switching contact open:
Traffic lights remain switched on in the OPEN door position after the two-way traffic control
times have expired.
- Switching contact closed:
Traffic lights are switched off in the OPEN door position after the two-way traffic control
times have expired.
Stage Operating mode
Automatic OFF
(SB 35)
Priority function
(SB31)
Photocell/closing
prevention device
(SB34)
J2
Automatic alterna-
tion of green phase
for entry and exit,
with start impulse
Switching contact
open: automatic
alternating operation
switched off
(operation as in H2)
Switching contact
open: Two-way
traffic control func-
tion (traffic lights in
push-pull operation)
Switching contact
closed: Automatic
closing timer func-
tion (traffic lights in
push-push operation)
No influence on
times
Switching contact
closed: automatic
alternating operation
Start impulse for
opening the door
when switching
contact is closed
No influence on the
function
6. Programming
14 Manual for installation and operation, Expansion module EM 130 GB (#96650)
Manual for installation and operation, Expansion module EM 130 GB (#96650) 15
Menu 3: Door open duration / green phase
When the automatic closing timer is activated, the door open duration is set here.
When the two-way traffic control is activated, the green phase for entry is set here.
Menu 4: Warning time / red phase
When the automatic closing timer is activated, the warning time is set here.
When the two-way traffic control is activated, the red phase for entry is set here.
Menu 6: Entry / exit green and red phase
The setting options in Menu 3 and 4 are altered here.
6. Programming
Functions of Menus 3 and 4 depending upon Menu 6
(changes in exit and entry times)
A6
The times for entry and exit are changed to the same degree.
Menu 3: Green phase for entry = green phase for exit
Menu 4: Red phase for entry = red phase for exit
B6
Only the entry times are changed.
Menu 3: Green phase for entry
Menu 4: Red phase for entry
C6
Only the exit times are changed.
Menu 3: Green phase for exit
Menu 4: Red phase for exit
Stage Function
A8 Fault
B8 Every request recognised (wiping impulse - 1 s)
C8 Entry request recognised (wiping impulse - 1 s)
D8 Exit request recognised (wiping impulse - 1 s)
Menu 8: Expansion module relay output
The relay output function of the expansion module is programmed here.
16 Manual for installation and operation, Expansion module EM 130 GB (#96650)
Legend:
LED off
LED on
LED flashes slowly
LED pulses
LED flashes quickly
Factory default setting
Not possible
Menu 6: Entry request
The entry request function is assigned here to a hand transmitter button.
Menu 7: Exit request
The exit request function is assigned here to a hand transmitter button.
Level 4 – Remote programming
Menu 6: Entry request
LED 7 flashes slowly -> press the hand transmitter button -> LED 7 flashes quickly
Menu 7: Exit request
LED 7 flashes slowly -> press the hand transmitter button -> LED 7 flashes quickly
The expansion module expands Level 4 to include the following menus:
6. Programming
Manual for installation and operation, Expansion module EM 130 GB (#96650) 17
6. Programming
Programming examples for two-way traffic control
Example 1
Door system and vehicle access (factory default settings)
- The traffic lights and the buttons for entry and exit are located in the direct vicinity of the door.
- The green phase time is identical for entry and exit.
- The red phase time is identical for entry and exit.
- The green phase should be extended if a photocell is driven through.
Description of the parameters:
- Two-way traffic control operation with extension of the green phase after a vehicle has driven through
the photocell (A2).
- Times: Green phase for entry and exit = 15 seconds
Red phase for entry and exit = 5 seconds
Legend:
A Entry
B Exit
6.1
A
B
5 sek. (M4)
5 sek. (M4)
15 sek. (M3)
15 sek. (M3)
6. Programming
Example 2:
Door system and vehicle access
- The traffic lights are located in the direct vicinity of the door or at an equal distance to the door.
- The buttons for entry and exit are located at different distances to the door.
- The duration of the green phase for entry is identical to the duration of the red phase for exit.
- The duration of the green phase for exit is identical to the duration of the red phase for entry.
- The green phase should be interrupted if a photocell is driven through.
Description of the parameters:
- Level 3 / Menu 2 is set to parameter B2.
- The times are programmed as follows:
Level 3 Stage / function
Menu 6 (setting the times) Stage C6 (exit times)
Menu 3 (green phase for exit) 5 sec.
Menu 4 (red phase for exit) 15 sec.
Legend:
A Entry
B Exit
18 Manual for installation and operation, Expansion module EM 130 GB (#96650)
The factory default settings do not need to be changed for the entry times.
6.2
A
B
15 sek. (M4)
5 sek. (M4)
5 sek. (M3)
15 sek. (M3)
6. Programming
Example 3:
Door system and vehicle access
- The traffic lights and the buttons for entry and exit are not located in the direct vicinity of the door.
- The green and red phases for entry and exit must be programmed to be different.
- A priority direction for entry / exit should be set.
Description of the parameters:
- Level 3, Menu 2 is set to parameter I2.
(If the automatic OFF contact is closed, an opening impulse is given).
- The times are programmed as follows:
Level 3 Stage / function
Menu 6 (setting the times) Stage C6 (exit times)
Menu 3 (green phase for exit) 10 sec.
Menu 4 (red phase for exit) 15 sec.
Legend:
A Entry
B Exit
Manual for installation and operation, Expansion module EM 130 GB (#96650) 19
The factory default settings do not need to be changed for the entry times.
6.3
A
B
15 sek.
5 sek. (M4)
10 sek.
15 sek. (M3)
English Copyright.
No part of this manual may be reproduced without our prior consent.
Subject to changes which are in the interest of technical improvements.
Version: 09.2010
#96650
1 - GB/KD 360304 - M - 0.5 - 0409
96650
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Marantec EM 130 Owner's manual

Type
Owner's manual

Marantec EM 130 is a two-way traffic control expansion module for the Control x.plus control unit. It enables automatic closing and prioritizes entry or exit through continuous green light for the selected direction. Additional features include adjustable door open duration, warning time, and the option for automatic alternating operation. The EM 130 also provides connections for signaling devices and external control elements.