Mircom LT-2009MIR RAM-2200-8 Installation guide

Type
Installation guide

This manual is also suitable for

Mircom LT-2009MIR RAM-2200-8 is an eight-zone LED expander for the FX-2200 fire alarm control panel. It provides up to 24 zone LEDs (8 alarm LEDs, 8 supervisory LEDs, and 8 trouble LEDs per module). The RAM-2200-8 can be used to expand the number of zones that can be monitored by the FX-2200, and it can also be used to provide additional visual feedback to the user.

The RAM-2200-8 is easy to install and can be mounted to the dead front of the FX-2200 using the included hardware. The expander is powered by the control panel, and it does not require any additional wiring.

Mircom LT-2009MIR RAM-2200-8 is an eight-zone LED expander for the FX-2200 fire alarm control panel. It provides up to 24 zone LEDs (8 alarm LEDs, 8 supervisory LEDs, and 8 trouble LEDs per module). The RAM-2200-8 can be used to expand the number of zones that can be monitored by the FX-2200, and it can also be used to provide additional visual feedback to the user.

The RAM-2200-8 is easy to install and can be mounted to the dead front of the FX-2200 using the included hardware. The expander is powered by the control panel, and it does not require any additional wiring.

INSTALLATION INSTRUCTIONS
RAM-2200-8 Eight-Zone LED Expander for FX-2200
Fire Alarm Control Panel
The RAM-2200-8 provides up to 24 Zone LEDs (8 alarm LEDs, 8 supervisory LEDs,
and 8 trouble LEDs per module) for the FX-2200.
Parts List
Qty 1 ... RAM-2200-8 module
Qty 4 ... #4 Hex Nuts
Qty 4 ... #4 Lock Washers
Qty 1 ... Ribbon Cable
Qty 1 ... Zone Label
NOTE: This component must be included in the control panel battery
calculation. Refer to the Battery Calculation Sheet in the FX-2200 Installation
Manual (LT-2000MIR) included with the control panel.
Installing the RAM-2200-8 Module
Before mounting the RAM-2200-8, fill out the Zone Label and insert it behind the
overlay.
1. Remove the right most black plate as viewed with dead front open.
2. Mount the RAM-2200-8 assembly to the dead front using the 4 nuts/lock washers.
3. If this is the first LED Expander: Connect the enclosed ribbon cable from “Output”
on the display board to “CON1 IN” on the RAM-2200-8 module.
If there is already at least one LED Expander present: connect one end of the
enclosed ribbon cable to “CON2 OUT” on the LED Expander to the right of the
new one. Connect the other end of the ribbon cable to the newly installed RAM-
2200-8 at “CON2 IN”.
In no event shall Mircom be liable for any direct, indirect or consequential damages,
loss of anticipated profits, loss of time or any other losses incurred by the buyer in
connection with the purchase, installation or operation or failure of this product.
Important!
Mircom recommends that the entire system be completely tested on a regular basis.
However, despite frequent testing and due to but not limited to, criminal tampering or
electrical disruption, it is possible for this product to fail to perform as expected.
Canada
25 Interchange Way
Vaughan, ON, L4K 5W3
Tel: (888) 660-4655
Fax: (905) 660-4113
www.mircom.com
USA
60 Industrial Parkway PMB 278
Cheektowaga, NY, 14227
Tel: (888) 660-4655
Fax: (888) 660-4113
LT-2009MIR Rev. 0
Front of the RAM-2200-8 Board Back of the RAM-2200-8 Board
FX-2200 Panel Layout
RAM-2200-8 Board
Figure 1. RAM-2200-8 Board Installation
Dead Front
Display Board
Output
Input
CON 1 IN
CON 2 OUT
CON 1 IN
CON 2 OUT
Mounting Plate
NAC Board
or
Relay Board
NAC Board
or
Relay Board
NAC Board
or
Relay Board
Dact Board
or
City Board
Main
Board
T/B
Battery
Optional
Transformer
Rectifier
Transformer
CON 5
Main Board
Battery
Mountin
g
Plate
LED
Display
Mounting Plate
Dead Front
Insert Zone Label
  • Page 1 1
  • Page 2 2

Mircom LT-2009MIR RAM-2200-8 Installation guide

Type
Installation guide
This manual is also suitable for

Mircom LT-2009MIR RAM-2200-8 is an eight-zone LED expander for the FX-2200 fire alarm control panel. It provides up to 24 zone LEDs (8 alarm LEDs, 8 supervisory LEDs, and 8 trouble LEDs per module). The RAM-2200-8 can be used to expand the number of zones that can be monitored by the FX-2200, and it can also be used to provide additional visual feedback to the user.

The RAM-2200-8 is easy to install and can be mounted to the dead front of the FX-2200 using the included hardware. The expander is powered by the control panel, and it does not require any additional wiring.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI