APC 66063 Datasheet

Type
Datasheet
9
MGE UPS SYSTEMS - 5102922200/AA
Contents of package ................................ 10
Storage .................................................... 10
Recycling of packing materials ................ 10
Function ................................................... 11
Overall view ............................................. 11
Connection to a UPS with a U-Talk port .. 12
Connection to a UPS with a Basic port .... 12
................................................................. 13
................................................................. 14
Operating anomalies ................................ 15
Cable replacement ................................... 15
Glossary ................................................... 16
Index ........................................................ 16
Contents
Card setting
Presentation
Installation
Operation
Troubleshooting
Appendices
All MGE UPS SYSTEMS products are protected by patents. They implement original technology which is not available to other
competitors of MGE UPS SYSTEMS.
To take evolving standards and technology into account, the technical characteristics contained in this document are not
binding unless confirmed by MGE UPS SYSTEMS.
This document may be reproduced only with the consent of MGE UPS SYSTEMS. Authorised copies must be marked
"Installation and user manual of the MGE UPS SYSTEMS acquisition card for U-Talk/Basic communications port
n° 5102922200".
MGE UPS SYSTEMS - 5102922200/AA
10
Contents of package
This optional equipment is made up of the
following components (see figure 1):
one acquisition card,
one DB9/DB9 RS232 serial
communications cable,
one installation and user manual for the
acquisition card (this document).
Storage
If the card is stored prior to installation, it
should remain in the original packing in a dry
place. The storage temperature range is
–40°C to +70°C.
Recycling of packing
materials
Packing materials must be disposed of in
compliance with applicable laws and
regulations.
Presentation
SA1
JMP2
J4
J3
JMP4
JMP5
JMP6
JMP3
JMP7
JMP1
Manuel d'installation et
d'utilisation
Installation and user
manual
LE SAVOIR FAIRE MERLIN GERIN
Acquisition board for
U-Talk/Basic
communication ports
Carte d'acquisition
pour port de
communication
U-Talk/Basic
SA1
JMP2
J4
J3
JMP4
JMP5
JMP6
JMP3
JMP7
JMP1
Fig. 1
11
MGE UPS SYSTEMS - 5102922200/AA
Overall viewFunction
The acquisition card is an optional part of
the MultiSlot module (see the installation
and user manual for the MultiSlot module,
ref. 5102919700).
The card acts as the interface between the
I2C bus of the MultiSlot module and the
supervised UPS (Uninterruptible Power
Supply).
Using the MGE UPS SYSTEMS proprietary
protocol (U-Talk) or the Basic protocol (dry
contacts), it acquires measurements, status
information and alarms from the UPS to
which it is connected and transmits the data
to the I2C bus of the MultiSlot module in
which it is installed.
Key:
1 jumpers and DIP switches for acquisition
card settings,
2 UPS U-Talk/Basic acquisition port,
3 green light indicating the operation of the
acquisition card,
4 reset button,
5 unused port,
Jumpers JMP4, JMP5 and JMP6 are not
used for this application.
SA1
JMP2
JMP4
JMP5
JMP6
JMP3
JMP7
JMP1
2
3
4
1
J3
J4
5
Fig. 2: Acquisition card for the MultiSlot module.
MGE UPS SYSTEMS - 5102922200/AA
12
Card settings
Connection to a UPS
with a U-Talk port
The default card settings are for this type of
connection. Figure 3 shows the
corresponding positions of the jumpers and
DIP switches. Before changing any of the
DIP switches on the SA1 block, the plastic
protection sheet must be removed.
Connection to a UPS
with a Basic port
Card settings must be modified as indicated
in figure 4 for communication with a UPS
equipped with a Basic port. Before changing
any of the DIP switches on the SA1 block,
the plastic protection sheet must be
removed.
SA1
JMP2
J4
J3
JMP4
JMP5
JMP6
JMP3
JMP7
JMP1
J3
J4
JMP1
JMP2
JMP3
JMP7
SA1
OFF
ON
SA1
JMP2
J4
J3
JMP4
JMP5
JMP6
JMP3
JMP7
JMP1
J3
J4
JMP1
JMP2
JMP3
JMP7
SA1
OFF
ON
SA1
JMP2
J4
J3
JMP4
JMP5
JMP6
JMP3
JMP7
JMP1
J3
J4
JMP1
JMP2
JMP3
JMP7
SA1
OFF
ON
Fig. 3
Fig. 4
13
MGE UPS SYSTEMS - 5102922200/AA
Installation
The acquisition card may be installed in any
of the four slots in the MultiSlot module. No
particular order is required (see the manual
of the MultiSlot module). Only the DB9 J3
connector on the acquisition card may be
used for connection. Connector J4 is
reserved for future applications.
Ue/In/Eing
10A/250V
1
2
U-Talk or Basic
UPS
U-Talk / Basic
Fig. 5
MGE UPS SYSTEMS - 5102922200/AA
14
Operation
When the acquisition card is installed in the
MultiSlot module, the following occurs:
the green light 3 on the acquisition card
flashes once every second during the start-
up phase,
if communications cards are connected to
the module, the green light 3 flashes more
rapidly and irregularly during initialization of
the dialogue on the I2C bus of the MultiSlot
module,
in U-Talk mode, once dialogue with the
UPS has been initialized, the green light 3
flashes when data is exchanged between
the UPS and the acquisition card,
in Basic mode, the green light 3 flashes
every three seconds.
SNMP
10BT
JBUS
UPS
U-Talk/Basic
3
Fig. 6
15
MGE UPS SYSTEMS - 5102922200/AA
Troubleshooting
Operating anomalies
AC-power problem
The green light 3 on the acquisition card
remains off:
check the supply of power to the MultiSlot
module,
check that the acquisition card is correctly
installed (fully inserted) in the module,
press the reset button 4 on the
acquisition card.
Start-up problem
The green light 3 on the acquisition card
remains on: press the reset button 4 on the
acquisition card.
Cable replacement
If the communications cable supplied with
the acquisition card is lost or damaged, a
cable wired as indicated in figure 7 may be
used.
If the problem continues, contact our
after-sales support department.
male DB9
connector
RS232 cable
RS232-cable wiring diagram
male DB9
connector
male DB9
connector
male DB9
connector
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
shielded
cable
body body
Fig. 7
MGE UPS SYSTEMS - 5102922200/AA
16
Appendices
Index
UPS (connection) ............................................................................................................p 12, 13
Warnings ( ) ..............................................................................................................p i
Communications cable....................................................................................................p 10, 15
Contents of package .......................................................................................................p 10
Settings ...........................................................................................................................p 12
Troubleshooting ..............................................................................................................p 15
Glossary
Basic: information exchange protocol using
dry contacts,
I2C: multi-point and multi-master
communications protocol and bus,
JBus: master-slave communications
protocol using a point-to-point (RS232) or
multi-point (RS485) serial link,
SNMP: Ethernet communications protocol,
UPS: Uninterruptible Power Supply,
U-Talk: point-to-point ASCII
communications protocol using an RS232
serial link. U-Talk is the MGE UPS
SYSTEMS proprietary protocol.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

APC 66063 Datasheet

Type
Datasheet

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI