Electrolux 5995615357 User manual

Category
Water heaters & boilers
Type
User manual

This manual is also suitable for

EN CONDENSING TANKLESS GAS WATER HEATER Installation Manual
SBB800T
Rev. 11/12
*SBB800T*
SP CALENTADOR A GAS TIPO CONDENSADO Manual de Instalación
5995615357 November 2012
Installation Manual
CONDENSING TANKLESS GAS WATER HEATER
EN19WI30LS
EP19WI30LS
Potential dangers from accidents during installation and use are divided into the following three
categories. Closely observe these warnings, they are critical to your safety.
Prohibited
Disconnect
Power
Ground
Be sure to do
WARNING:
If the information in this manual is not followed exactly, a re or explosion may result
causing property damage, personal injury or death.
DANGER indicates an imminently hazardous situation which,
if not avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation which,
if not avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which,
if not avoided, may result in minor or moderate injury.
DANGER
WARNING
CAUTION
Requests to Installers
r*OPSEFSUPVTFUIFXBUFSIFBUFSTBGFMZSFBEUIJTJOTUBMMBUJPONBOVBMDBSFGVMMZBOEGPMMPXUIF
installation instructions.
r'BJMVSFTBOEEBNBHFDBVTFECZFSSPOFPVTXPSLPSXPSLOPUBTJOTUSVDUFEJOUIJTNBOVBMBSFOPU
covered by the warranty.
r
$IFDLUIBUUIFJOTUBMMBUJPOXBTEPOFQSPQFSMZJOBDDPSEBODFXJUIUIJT*OTUBMMBUJPO.BOVBMVQPODPNQMFUJPO
r
"GUFSDPNQMFUJOHJOTUBMMBUJPOQMFBTFFJUIFSQMBDFUIJT*OTUBMMBUJPO.BOVBMJOBQMBTUJDQPVDIBOE
attach it to the side of the water heater (or the inside of the pipe cover or recess box if applicable),
or hand it to the customer to retain for future reference. Also, be sure to ll in all of the required
items on the registration/warranty card and to hand the registration/warranty card to the customer
BMPOHXJUIUIF6TFBOE$BSF.BOVBM
CAUTION
'0364&*/3&4*%&/5*"-"11-*$"5*0/4*/ 5)&6/*5&% 45"5&40/-:
/05*/5&/%&%'0364&*/$"/"%"03.&9*$0
Installation must conform with local codes, or in the absence of local codes,
UIF/BUJPOBM'VFM(BT$PEF"/4*;/'1"MBUFTUFEJUJPOBOEPS
$4"#/BUVSBM(BTBOE1SPQBOF*OTUBMMBUJPO$PEF/4$/(1*$
&MFDUSPMVY)PNF1SPEVDUT*ODSFTFSWFTUIFSJHIUUPEJTDPOUJOVF PS
change at any time, the designs and/or specications of its products
without notice.
Low NOx
Approved by
4$"2.%
OH+PSQQN
(Natural Gas Only)
1.
Included Accessories
The following accessories are included with the unit.
$IFDLGPSBOZNJTTJOHJUFNTCFGPSFTUBSUJOHJOTUBMMBUJPO
Q’ty
ShapePart
Tapping Screw
1
each
Part Shape
Q’ty
1
Remote Controller
4FFQ
Remote Controller
$PSEGUN
3$$03%
1
2.
Optional Accessories
The accessories listed below are not
included with the units, but may be necessary
for installation.
Q’ty
ShapePartPart Shape
Q’ty
Remote Controller
$PSEGUN
3$$03%
2VJDL$POOFDU$PSE
(2$)
1
1
1
each
Isolation Valves
(includes pressure
relief valve)
6TFBOE$BSF.BOVBM
8BSSBOUZ*OTUBMMBUJPO.BOVBM
(this document)
Bird Screen for
NN17$
7517$4
Bird Screen for
NN17$
7517$4
NN
PVC Terminal
7,)17$
1
1
Pipe Cover
(1$4464)
NNNN
)PSJ[POUBM)PPE
5FSNJOBUJPO175)-
SV Conversion Kit
(47$,)
r&MCPX
(With Inlet Screen)
r
*OTUBMMBUJPO.BOVBM
$IFDL-JTU
1
each
1
Neutralizer
/$
3
G
Quick Connect
Cord
Remote Controller Cord
Gas Supply Piping
Cold Water Supply
Hot Water
Remote Controller
Terminal Block
Cord
Connector
Cord
Connector
3.
Quick Connect Multi System Installation
r5IF2VJDL$POOFDU.VMUJ4ZTUFNBMMPXTUIFJOTUBMMBUJPOPGUXPVOJUTUPHFUIFSVUJMJ[JOHPOMZUIF2VJDL
Connect Cord.
Typical Plumbing
* When connecting two units, use only a
single remote controller.
Note: Connect the remote
controller to only one
of the units.
System Diagram
r*OTVMBUF UIF IPUXBUFS QJQJOHUP QSFWFOU IFBU MPTT *OTVMBUF BOE BQQMZ IFBUJOH NBUFSJBMT UP
the cold water supply piping to prevent heat loss and freezing of pipes when exposed to
excessively cold temperatures.
Union
Make this distance as short
as possible.
* The hot water temperature
will become unstable as the
pipe length increases.
Distance at center: 20.3 - 36.3 in. (515 - 922mm)
Quick Connect Cord
Union
Gas Valve
Union
Shutoff Valve
Shutoff Valve
Hot Water
Shutoff Valve
Cold Water
Distance on sides
2 - 18 in. (50 - 457mm)
Leave enough clearance around the plumbing to
apply insulation. It will be necessary to add
bends to the piping to ensure that this clearance
is available.
Size the piping to allow for the
maximum ow rates of the units.
The backow preventer is
put up before it diverges.
Pressure
Relief Valve
5IF2VJDL$POOFDU$PSEJTGUNMPOH*OTUBMMUIFVOJUTNNBQBSUGSPNFBDI
other to ensure the cord will be able to reach between the units. (See Typical Plumbing diagram).
(If the distance between the two units is too great, not only will the cord not be able to reach,
but the water temperature may also become unstable because of the difference in pipe length
between the two units).
199,900 BTU
16,000 BTU
228
4.0
1.3 2.8"
10.5"
ANSI Z21.10.3-2011/CSA 4.3-2011
15
150
4
EN19WI30LS1
4.
Before Installation
Checkup
r$IFDLUIFàYJOHCSBDLFUTBOEWFOUQJQFZFBSMZGPSEBNBHFPSXFBS3FQMBDFJGOFDFTTBSZ
DANGER
Do Not Use Equipment for Purposes Other Than Those Specified
r%POPUVTFGPSPUIFSUIBOJODSFBTJOHUIFUFNQFSBUVSFPGUIFXBUFSTVQQMZBTVOFYQFDUFEBDDJEFOUT
may occur as a result.
Check Water Supply Quality
r*GUIFXBUFSTVQQMZJTJOFYDFTTPGHSBJOTQFSHBMMPONH-PGIBSEOFTTBDJEJDPSPUIFSXJTF
impure, treat the water with approved methods in order to ensure full warranty coverage.
WARNING
CAUTION
Check the Gas
r$IFDLUIBUUIFSBUJOHQMBUFJOEJDBUFTUIF
correct type of gas.
r$IFDLUIBUUIFHBTTVQQMZMJOFJTTJ[FEGPS
199,900 Btuh.
Check the Power
r5IFQPXFSTVQQMZSFRVJSFEJT7"$BU)[
6TJOHUIFJODPSSFDUWPMUBHFNBZSFTVMUJOàSFPSFMFDUSJDTIPDL
Use Extreme Caution if Using With a Solar Pre-Heater
r6TJOHUIJTVOJUXJUIBTPMBSQSFIFBUFSDBOMFBEUPVOQSFEJDUBCMFPVUQVUUFNQFSBUVSFTBOE
possibly scalding. If absolutely necessary, use mixing valves to ensure output temperatures do
OPUHFUUPTDBMEJOHMFWFMT%POPUVTFBTPMBSQSFIFBUFSXJUIUIFRVJDLDPOOFDUNVMUJTZTUFN
Precautions on Vent Pipe Replacement
r5IFWFOUTZTUFNXJMMBMNPTUDFSUBJOMZOFFEUPCFSFQMBDFEXIFOUIJTBQQMJBODFJTCFJOHJOTUBMMFE
0OMZVTFWFOUNBUFSJBMTUIBUBSFTQFDJàFEJOUIJT*OTUBMMBUJPO.BOVBMGPSVTFPOUIJTBQQMJBODF3FGFS
UPUIF7FOU1JQF*OTUBMMBUJPOTFDUJPOGPSEFUBJMT*G17$$17$PS$BUFHPSZ*7MJTUFEQJQFJTBMSFBEZ
JOTUBMMFEDIFDLGPSQVODUVSFTDSBDLTPSCMPDLBHFTBOEDPOTVMUXJUIUIFWFOUQJQFNBOVGBDUVSFS
before reusing.
*NQSPQFSWFOUJOHNBZSFTVMUJOàSFTQSPQFSUZEBNBHFPSFYQPTVSFUP$BSCPO.POPYJEF
Snow Precaution
r*GUIJTQSPEVDUXJMMCFJOTUBMMFEJOBOBSFBXIFSFTOPXJTLOPXOUPBDDVNVMBUFQSPUFDUUIFWFOU
UFSNJOBUJPOGSPNCMPDLBHFCZTOPXESJGUTPSEBNBHFGSPNTOPXGBMMJOHPGGPGSPPGT
5.
Choosing Installation Site
 -PDBUFUIFBQQMJBODFJOBOBSFBXIFSFMFBLBHFGSPNUIFVOJUPSDPOOFDUJPOTXJMMOPUSFTVMUJOEBNBHF
to the area adjacent to the appliance or to the lower oors of the structure. When such locations
cannot be avoided, it is recommended that a suitable drain pan, adequately drained, be installed
under the appliance. The pan must not restrict combustion air ow.
rLocate the vent terminal so that there are no obstacles around the termination and so that exhaust
can't accumulate. Do not enclose the termination with corrugated metal or other materials.
r"WPJEQMBDFTXIFSFàSFTBSFDPNNPOTVDIBTUIPTFXIFSFHBTPMJOF
benzene and adhesives are handled, or places in which corrosive gases
(ammonia, chlorine, sulfur, ethylene compounds, acids) are present.
6TJOHUIFJODPSSFDUWPMUBHFNBZSFTVMUJOàSFPSDSBDLJOH
r"WPJEJOTUBMMBUJPOJOQMBDFTXIFSFEVTUPSEFCSJTXJMMBDDVNVMBUF
%VTUNBZCMPDLUIFBJSTVQQMZPQFOJOHDBVTJOHUIFQFSGPSNBODFPGUIF
device fan to drop and incomplete combustion to occur as a result.
r"WPJEJOTUBMMBUJPOJOQMBDFTXIFSFTQFDJBMDIFNJDBMBHFOUT
(e.g., hair spray or spray detergent) are used.
Ignition failures and malfunction may occur as a result.
r$BSCPO.POPYJEF1PJTPOJOH)B[BSE%POPUJOTUBMMUIJTXBUFSIFBUFSJOB
recreational vehicle or on a boat.
r5IFXBUFSIFBUFSJTEFTJHOFEGPSJOEPPSJOTUBMMBUJPOPOMZ/FWFSJOTUBMMJU
outdoors or in a bathroom, it may be damaged or a re may be caused.
r$POTVMUXJUIUIFDVTUPNFSDPODFSOJOHUIFMPDBUJPOPGJOTUBMMBUJPO
rInstall the water heater in an area that allows for the proper clearances
to combustible and noncombustible construction. Consult the rating
plate on the appliance for proper clearances.
r%POPUJOTUBMMUIFXBUFSIFBUFSJOBQMBDFXIFSFJUNBZCFUISFBUFOFECZ
falling objects, such as under shelves.
r5IFXBUFSIFBUFSNVTUCFJOTUBMMFEJOBQMBDFXIFSFTVQQMZBOEFYIBVTU
pipes can be installed as directed.
r%POPUJOTUBMMUIFXBUFSIFBUFSXIFSFUIFFYIBVTUXJMMCMPXPOPVUFS
walls or material not resistant to heat. Also consider the surrounding
trees and animals.
The heat and moisture from the water heater may cause discoloration
of walls and resinous materials, or corrosion of aluminum materials.
DANGER
WARNING
CAUTION
Prohibited
Prohibited
6
r"WPJEJOTUBMMBUJPOBCPWFHBTSBOHFTPSTUPWFT
r"WPJEJOTUBMMBUJPOCFUXFFOUIFLJUDIFOGBOBOETUPWF*GPJMZ
fumes or a large amount of steam are present in the installation
MPDBUJPOUBLFNFBTVSFTUPQSFWFOUUIFGVNFTBOETUFBNGSPN
entering in the equipment.
r*OTUBMMJOBMPDBUJPOXIFSFUIFFYIBVTUHBTáPXXJMMOPUCF
affected by fans or range hoods.
r5BLFDBSFUIBUOPJTFBOEFYIBVTUHBTXJMMOPUBGGFDUOFJHICPST
"WPJEJOTUBMMBUJPOPODPNNPOXBMMTBTUIFVOJUXJMMNBLFTPNF
operational noises while it is running.
r#FGPSFJOTUBMMJOHNBLFTVSFUIBUUIFFYIBVTUáVFUFSNJOBUJPOXJMM
IBWFUIFQSPQFSDMFBSBODFTBDDPSEJOHUPUIF/BUJPOBM'VFM(BT
$PEF"/4*;
Be sure to do
Prohibited
Prohibited
CAUTION
State of California: The water heater must be braced, anchored or strapped to avoid moving during
BOFBSUIRVBLF$POUBDUMPDBMVUJMJUJFTGPSDPEFSFRVJSFNFOUTJOZPVSBSFBPSDBMM&MFDUSPMVY)PNF
1SPEVDUT*ODBUBOESFRVFTUJOTUSVDUJPOT
5IF$PNNPOXFBMUIPG.BTTBDIVTFUUT5IFXBUFSIFBUFSDBOCFVTFEGPSIPUXBUFSPOMZBOEOPUJOB
combination of domestic and space heating.
'PS7FOUJOH.BOVGBDUVSFST3FRVJSFNFOUTDBMM&MFDUSPMVY)PNF1SPEVDUT*ODBUPS
visit us at www. electroluxappliances. com.
6.
Installation Clearances
#FGPSFJOTUBMMJOHDIFDLGPSUIFGPMMPXJOH
Install in accordance with relevant building and mechanical codes, as well as any local, state or
OBUJPOBMSFHVMBUJPOTPSJOUIF BCTFODF PG MPDBM BOE TUBUFDPEFTUPUIF/BUJPOBM'VFM(BT$PEF
"/4*;/'1"mMBUFTUFEJUJPO
WARNING
Item
Distance from combustibles
r.BJOUBJOUIFGPMMPXJOHDMFBSBODFT
from both combustible and
OPODPNCVTUJCMFNBUFSJBMT
$IFDL Illustration
r*GQPTTJCMFMFBWFNNPSNPSFPO
either side of the unit to facilitate inspection.
r*GQPTTJCMFMFBWFNNPSNPSFJO
front of the unit to facilitate maintenance
and service if necessary.
r*GQPTTJCMFMFBWFNNPSNPSF
above and below the vent pipe to facilitate
inspection and repair if necessary.
Securing of space for
repair/inspection
NN
or more
Distance from
the side
NN
or more
NN
or more
NN
or more
NNPSNPSF
NNPSNPSF
NN
or more
NN
or more
<When using indoor air for combustion>
r*GUIFVOJUXJMMCFJOTUBMMFEJOUIFWJDJOJUZPG
BQFSNBOFOULJUDIFOSBOHFPSTUPWFUIBU
has the possibility of generating steam
that contains fats or oils, use a *dividing
plate or other measure to ensure that the
unit is not exposed to air containing such
impurities.
* The dividing plate should be of
noncombustible material of a width
greater than the water heater.
Exhaust hood
Range
Dividing plate
Water
heater
$PPLJOH&RVJQNFOU
Clearance Requirements from Vent Terminations to Building Openings
<When supplying combustion air from the indoors>
"MMDMFBSBODFSFRVJSFNFOUTBSFJOBDDPSEBODFXJUI"/4*;BOEUIF/BUJPOBM'VFM(BT$PEF
"/4*;
Item
r
5IFSFNVTUCFBDMFBSBODFPGNN
PSNPSFJOGSPOUPGUIF'MVFUFSNJOBM
r5IJTSFTUSJDUJPOXJMMOPUCFBQQMJFEUPBO
BSFBXIFSFBOFGGFDUJWFTIJFMENBLFTB
DMFBSBODFPGNNPSNPSFJO
front of the exhaust outlet.
$IFDL Illustration
Outdoor Clearances to Opening
into Any Building
NN
or more
NN
or more
There must be no
building opening
within this area.
'MVFUFSNJOBM
NN
or more
NN
or more
7FOU$MFBSBODFT8IFO)FBUFSJT*OTUBMMFE
Indoors
'PSJOTUBMMBUJPOTJOUIF64"
rhCFMPXhIPSJ[POUBMMZGSPN PShBCPWF
any door, operable window, or gravity air inlet
into any building.
3' above any forced air inlet within 10'.
.BJOUBJOUIFGPMMPXJOHDMFBSBODFTUPBOZ
opening in any building:
Illustration
4' *
4' *
3' *
1' *
9
Vent Terminal
Clearance
A=
Above grade, veranda, porDIEFDL
or balcony
B=
Window or door that may be opened
C=
Permanently closed window
D=
Vertical clearance to ventilated soft
located above the terminal within a
IPSJ[POUBMEJTUBODFPGGFFUGSom the
center of the terminal
*
E=
Unventilated soft
*
'
Outside corner
*
G=
Inside corner
*
)
Each side of center line extended
above meter/regulator assembly
hNXJUIJOBIFJHIUhN
above meter/regulator assembly
I=
Service regulator vent outlet
3' (0.9m)
+
Nonmechanical air supply inlet or
combustion air inlet to any other
appliance
K=
.FDIBOJDBMBJSTVQQMZJOMFU
3' above if within 10'
L=
"CPWFQBWFETJEFXBMLPSQBWFE
driveway located on public property
Under veranda, porDIEFDLPS
balcony
.
.BJOUBJODMFBSBODFTJOBDDPSdance with local installation codes and the requirements of the gas supplier.
*

NCFMPXPSUPUIFTJEFPG
opening, or 1’ (0.3m)above opening
Air Supply Inlet
Area Where Terminal
is Not Permitted
Indoor Combustion Air
*
**
**
*
*
*
hNXJUIJOBIFJHIUhN
above meter/regulator assembly
3' (0.9m)
3' above if within 10'
*


CFMPXPSUPUIFTJEFPG
opening, or 1’ above opening

Outdoor Combustion Air
(Direct Vent)
Clearance Requirements from Vent Terminations to Building Openings
"MMDMFBSBODFSFRVJSFNFOUTBSFJOBDDPSEBODFXJUI"/4*;BOEUIF/BUJPOBM'VFM(BT$PEF
"/4*;
10
7.
Installation
Securing to the wall
Illustration$IFDL
%SJMMIPMFTGPSUIFSFNBJOJOHGPVSTDSFXT
)BOHUIFVOJUBHBJOCZUIFàSTUTDSFXBOEUIFO
insert and tighten the remaining four screws.
5BLFXBUFSQSPPàOHNFBTVSFTTPUIBUXBUFSEPFT
not enter the building from screws mounting the
device.
r.BLFTVSFUIFVOJUJTJOTUBMMFETFDVSFMZTPUIBUJUXJMM
OPUGBMMPSNPWFEVFUPWJCSBUJPOTPSFBSUIRVBLFT
%SJMMBTJOHMFTDSFXIPMFNBLJOHTVSFUPIJUBTUVE
*OTFSUBOEUJHIUFOUIFTDSFXBOEIBOHUIFVOJUCZ
UIFVQQFSXBMMNPVOUJOHCSBDLFU
3. Determine the positions for the remaining four screws
UXPGPSUIFUPQCSBDLFUBOEUXPGPSUIFCPUUPNBOE
remove the unit.
r5IFXFJHIUPGUIFEFWJDFXJMMCFBQQMJFEUPUIFXBMM*GUIFTUSFOHUIPGUIFXBMMJTOPU
sufcient, reinforcement must be done to prevent the transfer of vibration.
r%POPUESPQPSBQQMZVOOFDFTTBSZGPSDFUPUIFEFWJDFXIFOJOTUBMMJOH*OUFSOBMQBSUTNBZ
be damaged and may become highly dangerous.
r*OTUBMMUIFVOJUPOBWFSUJDBMXBMMBOEFOTVSFUIBUJUJTMFWFM
-PDBUJOH4DSFX)PMFT
.PVOUJOH
Structure
r8IFOJOTUBMMJOHXJUICBSFIBOETUBLFDBVUJPOUP
not inict injury.
r#FDBSFGVMOPUUPIJUFMFDUSJDBMXJSJOHHBTPSXBUFS
piping while drilling holes.
Item
CAUTION
Be sure to do
.PVOUJOH#SBDLFU
(upper)
-PDBUJPOPG4DSFX)PMF
-PDBUJOH4DSFX)PMFT
Installations at Elevations
"CPWFGU
r"EKVTUUIF EJQTXJUDIFT BTJMMVTUSBUFE JO UIF UBCMF UP
the right if this water heater is installed at an altitude
PGGUNPSIJHIFS
r%JTDPOOFDUQPXFSUPUIFXBUFSIFBUFSCFGPSF
DIBOHJOHUIF EJQ TXJUDIFT 'BJMVSFUPQFSGPSNUIJT
TUFQXJMMSFTVMUJOBDPEFEJTQMBZFEPOUIF
remote controller and a cease in operation. If this
occurs, disconnect, then reconnect power to the
water heater to reset the system.
/PUF1MFBTFSFGFSUPQBHFGPSUIFMPDBUJPOPGUIF
EJQTXJUDICBOL
Tapping Screw
* Do not change any other dipswitches.
* High elevation adjustment.
65
2,001 - 4,000 ft (611 - 1,220m)
0 - 2,000 ft (0 - 610m)
ON= OFF=
4,001 - 6,000 ft (1,221 - 1,830m)
6,001 - 8,000 ft (1,831 - 2,440m)
11
Filling the condensate trap with water
The condensate trap can be lled before connecting the vent pipe.
Filling the condensate trap before vent pipe installation.
DANGER
1SJPSUPJOJUJBMTUBSUVQNBLFTVSFUIBUZPVàMMUIFDPOEFOTBUFUSBQXJUIXBUFS
This is to prevent dangerous exhaust gases from entering the building.
'BJMVSFUPàMMUIFDPOEFOTBUFUSBQDPVMESFTVMUJOTFWFSFQFSTPOBMJOKVSZPSEFBUI
Please follow one of the procedures described below to ensure that the condensate trap is lled with water.
'JMMUIFDPOEFOTBUFUSBQCZQPVSJOHBQQSPYP[NMPGXBUFSJOUPUIFFYIBVTUBDDFTTPSZPOUIFUPQ
of the appliance as illustrated below.
Or, if the vent pipe has already been installed:
"GUFSJOTUBMMJOHUIFESBJOQJQFNBLFTVSFUIBUUIFBSFBBSPVOEUIFBQQMJBODFJTXFMMWFOUJMBUFEPQFOB
window or a door if necessary.
Then, operate the unit and verify that condensate is coming out of the drain pipe.
(During normal use of the water heater, condensate will begin to discharge from the drain pipe within
NJOVUFTPGVTF)PXFWFSEFQFOEJOHPOUIFTFBTPOBOEPSJOTUBMMBUJPOTJUFDPOEJUJPOTJUNBZUBLFMPOHFS
/PUF5IFDPOEFOTBUFEJTDIBSHFEGSPNUIFXBUFSIFBUFSIBTBQ)MFWFMPGBQQSPYJNBUFMZ
If required by local code, the condensate must be neutralized prior to disposal into the sewer
system.
3FGFSUPQBHFTGPSBEEJUJPOBMEFUBJMT
30 oz.
850ml
*OUBLF
Exhaust

Maximum Vent Lengths
rThis appliance has been designed to be vented
XJUIFJUIFSNNPSNN17$PS
CPVC pipe.
Do not exceed the following maximum vent lengths:
* Not including the termination
3FGFSUPQBHFGPSNBYWFOUMFOHUIT
XIFOVTJOHUFSNJOBUJPO7,)17$
r.BJOUBJOUIFTBNFWFOUQJQFEJBNFUFSGSPNUIF
heater ue to the vent termination. The exhaust
BOE JOUBLF QJQFT NVTU CF UIF TBNF WFOU QJQF
diameter.
8.
Vent Pipe Installation
WARNING
Be sure to do
$"3#0/.0/09*%&10*40/*/(
'PMMPXBMMWFOUTZTUFNSFRVJSFNFOUTJOBDDPSEBODFXJUISFMFWBOUMPDBMPSTUBUFSFHVMBUJPO
PSJOUIFBCTFODFPGMPDBMPSTUBUFDPEFJOUIF64UPUIF/BUJPOBM'VFM(BT$PEF"/4*
;/'1"mMBUFTUFEJUJPO
No. of Elbows
.BY4USBJHIU7FOU-FOHUI
 /" hN
 hN hN
 hN hN
 hN hN
Pipe diameter NN NN
r6OEFS OPSNBM DPOEJUJPOT UIJT BQQMJBODF XJMM
not produce an exhaust flue temperature
JO FYDFTT PG ' $ BOE TDIFEVMF 
PVC pipe may be used as the vent material.
*GSFRVJSFE CZMPDBMDPEFTDIFEVMFPS
CPVC may also be used on this appliance.
3FGFSUPQBHFGPSBEEJUJPOBMSFRVJSFNFOUT
r.BLF TVSFUIF WFOU TZTUFN JT HBT UJHIU BOE
XJMMOPUMFBL
r4VQQPSUUIFWFOUQJQFXJUIIBOHFSTBUSFHVMBS
intervals as specied by these instructions or
the instructions of the vent manufacturer.
r%P OPU DPNNPO WFOU PS DPOOFDU NPSFUIBO
one appliance to this venting system.
r
The total vent length including horizontal & vertical
vent runs should be no less than 3' (0.9m).
r %POPUTUPSFIB[BSEPVTPSáBNNBCMFTVCTUBODFT
OFBSUIF WFOU UFSNJOBUJPOBOE DIFDL UIBU UIF
UFSNJOBUJPOJTOPUCMPDLFEJOBOZXBZ
r4UFBNPSDPOEFOTFE XBUFS NBZDPNFPVU
from the vent termination. Select the location
for the termination so as to prevent injury or
property damage.
r*GTOPXJTFYQFDUFEUPBDDVNVMBUFUBLFDBSF
the end of the pipe is not covered with snow
or hit by falling lumps of snow.
General Requirements
Clearances
PVC or CPVC has been approved for use on this
appliance with zero clearance to combustibles.
13
5IFVOJUDBOCFBEKVTUFEUPBDDPNNPEBUFMPOHFSWFOUSVOTSFGFSUPUIFCFMPXUBCMFUPàOEUIF
maximum vent length based on the number of elbows. Adjust the dip switches according to the vent
condition noted in the tables below.
Note:
#ZEFGBVMUUIFVOJUIBTCFFOTFUUPUIFTIPSUMFOHUIVTJOHNNQJQFDPOEJUJPO8IFOBEKVTUJOH
UIFEJQTXJUDIFTGPSMPOHFSWFOUSVOTUIF#56)JOQVUPGUIFBQQMJBODFXJMMCFSFEVDFECZVQUP
Maximum Vent Length Adjustment Dipswitches
5XP elbows, maximum length = 3 ft. (0.9m)
XJUIEJQTXJUDIFTTFUBUTIPSUMFOHUIVTJOHNNQJQFDPOEJUJPO
5XPFMCPXTNBYJNVNMFOHUIGUN
XJUIEJQTXJUDIFTTFUBUMPOHMFOHUIVTJOHNNQJQFDPOEJUJPO
<.BYJNVN7FOU-FOHUI&YBNQMF>
r%JTDPOOFDU QPXFSUP UIFXBUFS IFBUFSCFGPSFDIBOHJOH UIF EJQ TXJUDIFT 'BJMVSFUPQFSGPSN
UIJTTUFQXJMMSFTVMUJOBDPEFEJTQMBZFEPOUIFSFNPUFDPOUSPMMFSBOEBDFBTFJOPQFSBUJPO
.
If this occurs, disconnect, then reconnect power to the water heater to reset the system.
/PUF1MFBTFSFGFSUPQBHFGPSUIFMPDBUJPOPGUIFEJQTXJUDICBOL
0
3
6
9
12
15
18
21
24
27
30
33
36
39
42
45
48
51
54
57
60
63
0.00
0.90
1.80
2.70
3.60
4.50
5.40
6.30
7.20
8.10
9.00
9.90
10.80
11.70
12.60
13.50
14.40
15.30
16.20
17.10
18.00
18.90
m10234ft
Vent length* Elbows
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Number of
pieces**
3
3
0%
-3%
-3%
-5%
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4
4
3
3
0%
-3%
-3%
-5%
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4
4
3
3
0%
-3%
-3%
-5%
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4
4
3
3
0%
-3%
-3%
-5%
3
3
3
4
4
4
4
4
4
4
4
4
4
4
3
3
0%
-3%
-3%
-5%
3
4
4
4
4
4
4
4
4
4
4
4
0
3
6
9
12
15
16
18
21
22
24
27
28
30
33
34
0.00
0.90
1.80
2.70
3.60
4.50
4.80
5.40
6.30
6.60
7.20
8.10
8.40
9.00
9.90
10.20
m1023ft
Vent length*
3” Pipe
Elbows
0
1
2
3
4
5
6
6
7
8
8
9
10
10
11
12
Number of
pieces**
1
1
0%
0%
-5%
-5%
1
1
1
1
2
2
2
2
2
2
2
2
2
2
1
1
0%
0%
-5%
-5%
1
1
2
2
2
2
2
2
2
2
2
1
1
0%
0%
-5%
-5%
2
2
2
2
2
2
2
2
0%
-5%
2
2
2
2
2
2
2
1
3
2
4
Short length using 4" (100mm) pipe
Short length using 3" (75mm) pipe
Long length using 3" (75mm) pipe
Long length using 4" (100mm) pipe
Short length using 4" (100mm) pipe
Short length using 3" (75mm) pipe
Long length using 3" (75mm) pipe
Long length using 4" (100mm) pipe
**Table assumes straight vent pieces are 3’ (0.9m) each.
Shorter or longer vent pieces may also be used up to the maximum
allowed vent length.
Do not change any other dipswitches.
Vent length condition.
1
78
ON= OFF=
2
3
4
4” Pipe
* Not including the termination.
* Not including the termination.
Refer to page 17 for max. vent lengths
when using termination VK3-H-PVC.
.BYJNVN7FOU-FOHUIBOE3FEVDFE*OQVU$POàHVSBUJPOT
The power must be unplugged
when adjusting the dip switches
to switch the airow amount.

WARNING

! # " # !
!$!!    "
    =   
F! > . C
!3/> .<0674
>-?> .<1554
!3/> .<330
 .
> .<1453
> .<382
 9 =!
>.>   ! 
I =#>>!3/!A E
I
I E" !!  
I <@    J 2()/8*AA $!!  #
@A"! 
I ?@ ,AE ! "@# 
!A !, AE ! @@"9
 D!#! A
 "@!@AB J 
 B ! @#,, =# 
"A!E   !  @" @
I
I >>@"A! E G @! @
! @A!#! = !A2()/8* " !
E   !  " 
2%3%!7/#@! ,E" <=:! A 
E@!@#! 4'
05H)37*
.
A@E
+ !   
11H)55*
2
3
1
0 17H)73*
34H)024*
28H)006*
40H)042*
46H)060*
I  F AEF!"  9
> ? >>
<@" E !  J @E @
I
I @! @  "    " @A  
< !E  E  ! @! #
) &><3->,! &><2->E!2%)64*>>*
?    E  ,!    !

3%)0//*+2%)64*+
A 06AF"  
E!  >;2-:->

Vent Pipe Installation
Horizontal Vent Termination- PVC/CPVC Materials Only
Intake and exhaust should face the same direction.
Intake and exhaust should keep the same
pressure zone.
2ft. Min
Interior View
Interior View Exterior View
Interior View Exterior View
1ft. Min1ft. Min
0
Insert the bird screen.
90° elbow vertical setting (downward).
0
Ensure at least 3ft (0.9m) or more distance between
the near edge of the air intake pipe or exhaust pipe
to the inside corner of a wall.
0
Ensure at least 2ft (0.6m) or more distance between
intake pipe and exhaust pipe.
The distance is measured at inside of pipe to inner
dimension.
0
Intake and exhaust should face the same direction.
Intake and exhaust should keep the same
pressure zone.
0
Insert the bird screen.
90° elbow vertical setting (downward).
0
Ensure at least 3ft (0.9m) or more distance between
edge of air intake pipe or exhaust pipe and corner wall.
0
Upper side is exhaust, lower side is intake.
The reverse connection is not allowed.
0
Ensure at least 1ft (0.3m) or more distance between
intake pipe and exhaust pipe.
The distance is measured at the outlets of
intake port (terminal) and exhaust port (terminal).
0
Intake and exhaust should face the same direction.
Intake and exhaust should keep the same
pressure zone.
0
Insert the bird screen.
90° elbow vertical setting (downward).
0
Ensure at least 3ft (0.9m) or more distance between
edge of air intake pipe or exhaust pipe and corner wall.
0
The side distant from wall is intake, the side near the
wall is exhaust.
The reverse connection is not allowed.
0
Ensure at least 1ft (0.3m) or more distance between
intake pipe and exhaust pipe.
The distance is measured at inside of pipe to inner
dimension.
0
0
Exhaust
Intake
Exhaust Intake
1ft. Min
Exterior View
Exhaust
Exhaust
Intake
Intake
Exhaust Intake
3” Min
WARNING
If the distance between the air inlet and exhaust vent terminations is too short, the water heater
will draw in the exhaust gases through the intake. There is a risk of inadequate combustion air
for the water heater, increasing Carbon Monoxide (CO) emissions and noise due to vibration.
0
Termination elbows must be oriented vertically, pointing directly downward. Attempts to prevent
exhaust air from entering the air inlet by angling termination elbows in directions other than
directly downward will increase the risk of freezing.
0
Reversing the air intake and exhaust pipes is not allowed.
Carbon Monoxide (CO) emissions and noise due to vibration will increase.
3” Min
3” Min
5.9”
5.9”
5.9”
16
V
ertical Vent Termination- PVC/CPVC Materials Only
=
=
=
=
=
=
=
=
Horizontal Vent Termination- PVC/CPVC Materials Only
=
=
=
=
=
=
=
=
Hanger
Straps
**1' mini
* Not supplied with water heater,
order separately.
mum recommended,
but not required.
3 ft. Min.
FirestopFirestop
Firestop/Support
Roof
Flashing
Roof
Flashing
Hanger
Strap
**1'
Minimum
**1'
Minimum
Support
"256,
"256,<,4:
$6=(8+9
Intake
Exhaust
<,4:
$6=(8+9
Intake
Exhaust
5<,83(>03;3
945=2,<,2
58=/0*/,<,8
09.8,(:,8
5<,83(>03;3
945=2,<,2
58=/0*/,<,8
09.8,(:,8
49,8:08+
"*8,,404
4+5-
2)5=
":583
522(8
":583
522(8
9022;9:8(:,+54:/,2,-:3(1,9;8,:51,,6(+09:(4*,5-A3
58=0+,8),:=,,4:/,04:(1,(4+,>/(;9:=/,4049:(2204.:/,<,4:60604.
#/, %#:,8304(:0543(?),;9,+0462(*,5-,2)5=9(9:/,
/580@54:(2<,4::,8304(:0549:0945:4,*,99(8?:5;9,)08+9*8,,49
=0:/:/, %#:,8304(:054
#,8304(:,(:2,(9:33()5<,.8(+,58()5<,945=204,
#,8304(:,(:2,(9:A3()5<,(6;)20*=(21=(?A3
-853:/,*53);9:054(0804:(1,5-(4?(6620(4*,(4+A3
-853(4?5:/,8);02+04.56,404..(9;:020:?3,:,89,8<0*,8,.;2(:58,:*
#,8304(:,(:2,(9:A3()5<,(4?-58*,+(08042,:=0:/04
A3A3),25=A3/580@54:(22?-85358A3
()5<,(4?+558=04+5=58.8(<0:?(08042,:04:5(4?);02+04.6,8
(:054(2;,2(95+,"' 
"256,:/,/580@54:(2<,4:;6=(8+9-58,<,8?33
:5=(8+:/,:,8304(:054
$9,(*54+,49(:054+8(040-4,*,99(8?
4:/,53354=,(2:/5-(99(*/;9,::9(*(8)543545>0+,+,:,*:58
098,7;08,+-58(2290+,=(22/580@54:(22?<,4:,+.(9-;,2,7;063,4:
2,(9,8,-,8:5#,*/40*(2;22,:04#-58-;22049:(22(:054
049:8;*:0549
9022;9:8(:,+54:/,2,-:3(1,9;8,:51,,6(+09:(4*,
5-A358=0+,8),:=,,4:/,04:(1,(4+,>/(;9:
=/,4049:(2204.:/,<,4:60604.
#,8304(:,(:2,(9:A3-853:/,*53);9:054(08
04:(1,5-(4?(6620(4*,(4+A3-853(4?5:/,8
);02+04.56,404..(9;:020:?3,:,89,8<0*,8,.;2(:58,:*
4*259,,>:,8058<,4:9?9:,39),25=:/,855-204,:52030:
*54+,49(:054(4+685:,*:(.(049:3,*/(40*(2-(02;8,
&/,4:/,<,4:6,4,:8(:,9(D55858*,0204.(4+0945:
8;4404.04(E8,8(:,+9/(-:(E8,9:56(4+9;6658:09
8,7;08,+
&/,4:/,<,4::,8304(:0540925*(:,+45:2,99:/(4
A3-853(<,8:0*(2=(225890302(85)9:8;*:054
:,8304(:,()5<,:/,855-(:2,(9:A3);:45:
358,:/(4A304(**58+(4*,=0:/:/,(:054(2
;,2(95+,"' 
85<0+,<,8:0*(29;6658:,<,8?A358(98,7;08,+
)?:/,<,4:606,3(4;-(*:;8,8A9049:8;*:0549
9/58:/580@54:(29,*:054098,*533,4+,+:568,<,4:
+,)809-853-(2204.04:5:/,=(:,8/,(:,8
&/,4;904.(/580@54:(29,*:0549256,:/,/580@54:(2
<,4:B;6=(8+9-58,<,8?B33:5=(8+:/,
:,8304(:054:5+8(04*54+,49(:,
A30403;38,*533,4+,+
);:45:8,7;08,+

5:9;6620,+=0:/=(:,8/,(:,8
58+,89,6(8(:,2?
&/,4*/55904.04:(1,(4+,>/(;9::,8304(:0549?5;3;9:;9,:/,
9(3,:?6,5-,2)5=0,)5:/C,2)5=958)5:/C,2)5=9
#/09=022/,26=0:/6856,8*53);9:054)?6;::04.)5:/:,8304(:054904
:/,9(3,68,99;8,@54,
&/,4*/55904.04:(1,(4+,>/(;9::,8304(:0549?5;3;9:;9,:/,
9(3,:?6,5-,2)5=0,)5:/C,2)5=958)5:/C,2)5=9
#/09=022/,26=0:/6856,8*53);9:054)?6;::04.)5:/:,8304(:054904
:/,9(3,68,99;8,@54,
49,8:08+
"*8,,404
4+5-
2)5=
49,8:08+"*8,,4
044+5-2)5=
B04
Vent Pipe Installation

No. of
Elbows
3
2
1
4
Max. Straight Vent Length**
3" (75mm) PVC or CPVC
Max. Straight Vent Length**
4" (100mm) PVC or CPVC
** Not including the concentric termination
16' (4.8m)
N / A
22' (6.6m)
28' (8.4m)
30' (9.0m)
N / A
36' (10.8m)
42' (12.6m)
Maximum Vent Length Adjustment Dip switches.
0
3
6
9
12
15
18
21
24
27
30
33
36
39
42
0.00
0.90
1.80
2.70
3.60
4.50
5.40
6.30
7.20
8.10
9.00
9.90
10.80
11.70
12.60
m1023ft
Vent length*** Elbows
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
N /A
N /A
N /A
N /A
N /A
N /A
N /A
N /A
N /A
N /A
N /A
N /A
N /A
N /A
N /A
Number of
pieces****
-5%
-5%
3
3
0%
3
3
4
4
4
4
4
4
4
4
4
4
4
3
3
0%
4
4
4
4
4
4
4
4
4
4
4
4
4
-3%
-3%
-3%
-3%
-3%
-5%
4
4
4
4
4
4
4
4
4
4” Pipe
<Maximum Vent Length and Reduced Input Congurations>
*** Refer to page 13 for 3" pipe Maximum Vent Length Adjustment Dipswitches table.
3
4
Short length using 4" (100mm) pipe
Long length using 4" (100mm) pipe
****Table assumes straight vent pieces are 3’ (0.9m) each.
Shorter or longer vent pieces may also be used up to the maximum
allowed vent length.
G
G
G
G
G
G
G
Hanger
3" (75mm) or
4" (100mm)
Intake*
Horizontal Vent Termination- 3" (75m) Concentric PVC/CPVC Termination
3" (75m
m
) or
4" (100m
m
)
Exhaust*
Straps
The concentric termination may be shortened,
but not lengthened from its original factory
supplied length.
The concentric termination may only be used
for horizontal terminations.
Terminate at least 12" (300mm) above grade or
above snow line.
Terminate at least 7' (2.1m) above a public walkway,
6' (1.8m) from the combustion air intake of any
appliance, and 3' (0.9m) from any other building
opening, gas utility meter, service regulator etc.
Terminate at least 3' (0.9m) above any forced air
inlet within 10' (3m), 1' (0.3m) below, 1' (0.3m)
horizontally from or 1' (0.3m) above any door,
window, or gravity air inlet into any building per
National Fuel Gas Code ANSI Z223.1/NFPA 54.
Slope the horizontal vent 1/4" upwards for every
12" (300mm).
Use a condensation drain if necessary.
In the Commonwealth of Massachusetts a carbon
monoxide detector is required for all side wall
horizontally vented gas fuel equipment.
Please refer to Technical Bulletin TB 010606 for full
installation instructions.
Slope vent
Upwards
* 4" (100mm) pipe requires the use of a reducing coupling
just prior to the termination.
G
G
G
G
3" (75mm) or 4" (100mm) PVC or CPVC pipe
may be used with the concentric termination.
Maintain the same vent pipe diameter from the
water heater ue to the termination.
Do not exceed the maximum vent lengths as
specied in this section.
When using 4" (100mm) pipe, it will be necessary
to use 4" (100mm) x 3" (75mm) reducing couplings
and a short section of 3" (75mm) pipe to connect to
the termination.
Use no more than a 6" (150mm) section of pipe to
make the connection between the reducing
couplings and the termination.
G
Install a securing strap to prevent movement of
the termination.
Strap
There must be a 1" (25mm) to 4" (100mm) clearance
between the outside wall and the air intake section
of the termination as illustrated on the left.
1" (25mm) to
4" (100mm)
Insert Bird Screen ***
in End of Termination
*** Not supplied with
water heater,
order separately.

Vertical Vent Termination- PVC/CPVC Materials Only
Firestop
Firestop/Support
Roof
Flashing
Storm
Collar
Hanger
Strap
Horizontal Vent Termination- PVC/CPVC Materials Only
Hanger
Straps
**1' (0.3m) Minimum
Slope vent
Upwards
**1' (0.3m) Minimum
* Not supplied with water
heater, order separately.
recommended, but not required.
Insert Bird
Screen* in
Each End
of Tee
Support
Insert Bird
Screen* in
End of 90
Elbow
Slope vent
Upwards
Pipe Material PVC or CPVC
* Not supplied with water
heater, order separately.
Max. Straight Vent Length
3 41' (12.6m)
No. of Elbows
4" (100mm) Pipe
3" (75mm) Pipe
2 47' (14.4m)
1
*** Not including the termination.
53' (16.2m)
**1' (0.3m)
Minimum
**1' (0.3m) minimum
recommended, but not required.
***
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
A tee, 45 elbow, or the PVT-HL termination may be used
for the vent termination. It is not necessary to use bird
screens with the PVT-HL termination.
Terminate at least 12" (300mm) above grade or above
snow line.
Terminate at least 7' (2.1m) above a public walkway,
6' (1.8m) from the combustion air intake of any appliance,
and 3' (0.9m) from any other building opening, gas utility
meter, service regulator etc.
Terminate at least 3' (0.9m) above any forced air inlet within
10' (3m) , 4' (1.2m) below, 4' (1.2m) horizontally from or
1' (0.3m) above any door, window, or gravity air inlet into any
building per National Fuel Gas Code ANSI Z223.1/NFPA 54.
Slope the horizontal vent 1/4" upwards for every 12" (300mm)
toward the termination.
Use a condensation drain if necessary.
In the Commonwealth of Massachusetts a carbon monoxide
detector is required for all side wall horizontally vented gas
fuel equipment.
Please refer to Technical Bulletin TB 010606 for full installatio
n
instructions.
When installed in a manufactured home, all combustion air
must be supplied from the outdoors as shown on pages 15 - 17.
Terminate at least 6' (1.8m) from the combustion air
intake of any appliance, and 3' (0.9m) from any other
building opening, gas utility meter, service regulator etc.
Enclose exterior vent systems below the roof line to limit
condensation and protect against mechanical failure.
When the vent penetrates a oor or ceiling and is not
running in a re rated shaft, a restop and support is
required.
When the vent termination is located not less than
8' (2.4m) from a vertical wall or similar obstruction,
terminate above the roof at least 2' (0.6m), but not
more than 6' (1.87m), in accordance with the National
Fuel Gas Code ANSI Z223.1/NFPA 54.
Provide vertical support every 3' (0.9m) or as required
by the vent pipe manufacturer's instructions.
A short horizontal section is recommended to prevent
debris from falling into the water heater.
When using a horizontal section, slope the horizontal
vent 1/4” upwards for every 12” (300mm) toward the
termination to drain condensate.
When installed in a manufactured home, all combustion air
must be supplied from the outdoors as shown on pages 15 - 17.
Exhaust
Intake
Exhaust
4 35' (10.8m)
41' (12.6m)
47' (14.4m)
53' (16.2m)
35' (10.8m)
Intake
90 Elbow
SV Conversion Kit
Accessory
(#SV-CK-3)
90 Elbow
SV Conversion Kit
Accessory
(#SV-CK-3)
Inlet screen
Inlet screen
3” Min.
Vent Pipe Installation (When supplying combustion air from the indoors (SV, non-direct vent))
t%JTDPOOFDUQPXFSBOEUVSO0/EJQTXJUDIJGDPNCVTUJPOBJSXJMMCF
supplied from the indoors as illustrated to the right. Refer to page 29 for
the location of the dip switch bank.
t47$POWFSTJPOLJU47$,JTSFRVJSFEGPSUIFBJSJOUBLF.
* Dip switch No.3 is turned on.
'BJMVSFUPQFSGPSNUIFBCPWFTUFQTDPVMESFTVMUJOBàSFPSFYQMPTJPODBVTJOH
property damage, personal injury or death.
3FGFSUPUIFJOTUSVDUJPOTQSPWJEFEXJUIUIFDPOWFSTJPOLJUGPSBEEJUJPOBMEFUBJMT
WARNING
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40