  • Hello! I've reviewed the user manual for the Aim MyChron5 and MyChron5S temperature setting devices. This document provides detailed instructions on how to configure temperature settings in manual mode, specifically for the MyChron5S model. It also covers various harness types and sensor inputs. I'm ready to answer your questions about the devices and the information provided in this document.
  • Can I configure the temperature setting in Manual mode on MyChron5/5S?
    How do I configure the temperature setting in manual mode?
    What harness types are supported?
    When using TC/TR wiring, which sensor should be in IN1 and IN2?
1
Release 1.00 July 5th 2022
Configuring
Setting temperatures in “Manual” mode
Question:
Can I configure the temperature setting in Manual mode on MyChron5/5S?
Answer:
You can only configure this setting on MyChron5S.
To configure the temperature setting in manual mode, you have to access on the main menu of the
device System Setting Temperature Setup.
Harness Type: indicate the extension of the sensors connected to the MyChron5S, it could be:
TC/TR Thermocouple Thermo-resistor
TR/TR Thermo-resistor - Thermo-resistor
TC/TC Thermocouple Thermocouple
Temperature IN1/IN2: configure the two sensors inserting the correct labels.
Configuring
2
Release 1.00 July 5th 2022
Please note: in case you configure the setting with the TC/TR wiring, we remind our users that it is
mandatory to insert in the first input Exhaust Temp and in the second Water Temp, as shown in the
image below:
/