Caroma 2284848 Installation guide

  • I've reviewed the installation instructions for the Caroma Liano Nexus Bath Outlet. This document provides guidance on proper installation, highlighting important considerations for pipework and pressure requirements. I'm ready to answer any questions you might have about installing this product.
  • Is this product suitable for gravity feed systems?
    What must be done with the pipework before installation?
    What is the maximum hot water temperature?
    What is the maximum static pressure at any outlet within a building?
IS1297A(12/13)
R
PLUMBERS INSTALLATION INSTRUCTIONS
LIANO NEXUS - BATH OUTLET
Important Information
*
All pipework must be thoroughly flushed prior to
installation.
*
Not suitable for gravity feed systems.
15mm
G1/2 B
12
Wall/Tile face
Hot and cold water inlet pressures should be equal.
Maximum hot water temperature : 80 C.
IMPORTANT
Pressure & Temperature Requirements.
New Regulation :-500 kPa maximum static pressure
at any outlet within a building.
(Ref. AS/NZS 3500.1-2003, Clause 3.3.4)
Static inlet pressure range : 150 -1000 kPa
Installation
Check that threaded nipple (1) is the correct length, as
shown. Apply thread tape to the thread.
Screw the inlet of the bath outlet (2) onto the threaded
nipple (1) and position as required, taking care not to
damage the decorative finish. DO NOT OVERTIGHTEN.
2)
1)
/