Hardy HI6500 Quick Start

Type
Quick Start
HI6500seriesQuickStartGuide
TheHI6500seriesaresinglechannelinstrumentsdesignedtoprocess
signalsfromanalogloadcellsandoutputstablegrossornetweight
readingstoadisplay,aPLCorPC.
ThisQuickStartGuideisintendedforusersthatarealreadyfamiliar
withsettingupHardyProcessSolutionsweighinginstruments.
AcompleteUser’sGuidecanbefoundunderDocumentsandPrograms
online:www.hardysolutions.comClicktheproductmenu>Weighing
Instruments>WeightProcessors>HI6500.ThenclickontheDocs&
ProgramstabtodownloadtheUser’sGuide.
PanelInstallation:
1. Usetemplateprovidedtodrilltheholepatternintopanel.
2. Installthedisplayontothepanelusing4mmnutsandwashers,
tightenuntilgasketiscompressedanddisplaybezelcomesin
contactwiththepanel.Donotovertightenortheinstrument’scase
maycrack.
3. Connectthedisplaycabletodisplayandthentotheinstrument.
4. Slidetheinstrumentontothreadedrodsandsecureinplacewith
8mmx4mmretainingnutsusingan8mmnutwrench(donotover
tighteninstrumentretainingnuts,overtightingcouldcausethe
instrumenttocrack).
DINRailInstallation:
1. Usetemplateprovidedtodrilltheholepatternintopanel
2. Installthedisplaypanelusing4mmnutsandwashers,tightenuntil
gasketiscompressed(4mmscrewstightenedwithan8mmnut
wrench)withalengthlengthappropriatetopanelthicknesscanbe
usedinplaceofthe4mmrodssentwiththeunit).
3. PlacetheinstrumentontotheDINrail,slideDINrailclipupuntilit
snapsintoplacetosecure.
4. Connectthedisplaycabletothedisplaypanelandinstrument
(legthenthecableasneededbyusingathinscrewdrivertorelease
andreplacewiresbetweenthetwoconnectors).
Wiring:
1. Removeconnectorsfromtheinstrumentandwireaspermarkings
foundontheconnectorlabels.
2. Whenusing4wiresensorsplaceajumperbetweenExcitation(+)
andSense(+)andajumperbetweenExcitation()andSense().
3. Groundingoftheinstrumentisrecommendedbyconnectingto
eitherofthe2screwslocatedleftofpowerconnectororrightofthe
RS485connector.
Analog(HI6510only)USB
4. Connectto1227VDCpowersource
 
DisplayMenuTree

InitialSetUp:
SetUpmaybeperformedthroughthefrontpaneldisplayorthrough
theintegratedWebserver.IfsettingupusingtheWebserver,first
connectanEthernetcablebetweentheinstrumentandandthenfollow
theCommunications>EthernetTCP/IPinstructionsbelow.
Suggestedflowwhensettinguptheinstrumentforthefirsttime:
Ifsettingupaninstrumentwithoutadisplayforthefirsttime,skipto
thecommunicationsectionbelow.

SETUP(minimum)
1) Unit
2) Capacity
3) Grads
4) DecimalPoint
5
)
MotionTolerance
Filter
1) NumAverages
2) Waversaver
Calibration
1) CalDate
2) CalMethod
a. C2eCal
b. HardCal
3) CompleteCal
Procedure
Calibration: 
Sectionusedtocalibratetheinstrumenttothesensor(s)used.
C2ElectronicCalibration
1) Removeallweightfromthescale.
2) PressDoC2Cal.
3) Placeaverificationweightonthescaletoensurecalibrationis
successful.
HardCal‐ 
1) InputtheSpanWeight.Thespanweightshouldbeabout80%of
thescalecapacity.
2) InputCalLowWeight.Withnothingonthescale,theCalLow
Weightis0,with5lbsonthescale,theCalLowWeightwouldbe5.
3) PressDoCalLowtosetthelowpointonthecalibrationcurve.
4) PlacetheSpanWeightontothescale.
5) PressDoCalHi.
RefertoUser’sGuideifadjustmentstoothercalibrationrelated
parametersarerequired.
Communication:
Sectionusedforsettingupcommunicationstotheinstrument.
EthernetTCP/IP
1) ConnectanEthernetcablebetweentheinstrument’sRJ45
connectorandaPC,thenpoweruptheinstrument.Acrossover
cableisnotrequired,butcanbeused.
2) Theinstrumentwillautonegotiatesettingssuitableforavarietyof
operatingsystemsandnetworkconfigurations.Waitapproximately
15secondsandchecktoseeifthegreenlightoftheEthernetportis
onandblinkingifso,skiptostep8youareconnected.
3) IfthegreenlightontheEthernetportdoesnotlightup,checkthat
theunit’sEnableDHCPisturnedoffandfollowsteps4through9.
4) Usingtheunit’sFixedIPaddress(thedefaultis192.168.000.100),
thePCmustnowbeassignedauniqueIPaddress(forexample,
192.168.000.101)
TherearetwosimplerulesfortheIPAddress:
Itmusthavethesamenetwork
identifierasthecomputer
Itmusthaveadifferentnode
identifierthanthecomputer.
5) OnaPCrunningwindows,openInternetProperties(TCP/IP).
6) Clickinthe‘UsetheFollowingIPAddress’checkbox;thenenterthe
followingintotheTCP/IPPropertiesdialog.
IPAddress=192.168.0.101
SubnetMask=255.255.255.000
7) SelectOKontheTCP/IPPropertiesdialogbox.Thecomputerisnow
fullyconfigured.Toreturnthecomputertotheoriginalnetwork
settings,returntothe‘InternetProperties(TCP/IP)dialog,select
‘ObtainanIPaddressautomatically,’andclickOK.
8) TheHI6500seriesinstrumentisnowconfiguredtocommunicate
withthePC.EntertheHI6500seriesinstrumentIPaddressintothe
WindowsPCWebbrowsertoaccesstheembeddedwebbrowser.
Forexample:http://192.168.000.100
SeetheHI6500User’sGuideforsettingupEtherNet/IP,EthernetUDP
andModbusRTUcommunicationprotocols.SetupoftheAnalog
communications(HI6510only),Printer,andUSBarealsolocatedinthis
section.
Diagnostics:Sectionusedfordiagnosticsofsystem.RefertoUser’s
Guideiftroubleshootinganduseofdiagnosticsmenuis
required.
Display:Sectionusedforadjustingvariousaspectsofthedisplay,
includingcontrast,brightness,andsplitscreenfeature.
Filter:Sectionusedtostabilizeweighreadingsinanunstable
environment.
WAVERSAVER:Presstheenterbuttonandusethearrowkeystoselect
theappropriatesetting.WAVERSAVEReliminates
unwantednoiseandistypicallysetat1.0Hz.
NumAverages:Setthenumberofreadingstoaveragetoprovidea
stableweight.
Information:Sectionusedforcheckinginstrumentserialnumber,
andfirmwarerevision.
Language:Sectionusedforchanginglanguage.
Operations:SectionusedforsettingupparametersrelatedtoTare,
CountandZeroofscale.
Security:ItishighlyrecommendedtoseetheUser’sGuidefor
settingupsecurityfunctionsontheinstrument.
Impropersetupofthesecuritysettingscouldcausea
usertobelockedoutfromusingthedevice.
Setup:Sectionusedforsettingupoperationparametersofthe
instrument.
Capacity:Setsthenormaloperatingcapacityofscale.
DecimalPoint:Setstodecimalpointfortheweightresolution.
Grads:Setsthegraduationsizeofthedisplayincrements.
InstrumentID:Allowstheinstrumenttobenamed.
MotionTol:Choosethelevelofacceptablescaleinstability.
OperatorID:OptionalareaforenteringanoperatorID.
Unit:Choosetheunitssuchaslbs.orkgthatisdesiredto
showonthescale.
HardyProcessSolutionssincerelyappreciatesyourbusiness.Weencourage
inputabouttheperformanceandoperationofourproductsfromour
customers.Shouldyounotunderstandanyinformationinthisguideor
experienceanyproblemswiththisproduct,pleasecontactourTechnical
SupportDept.at:
Phone:(858)2782900
TollFree:18008215831
FAX:(858)2786700
EMail:hardysupport@hardysolutions.com
Orvisitourwebsiteat:
http://www.hardysolutions.com
ProudlymadeintheU.S.A
PN:0596033201Rev.A10/13
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Hardy HI6500 Quick Start

Type
Quick Start

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI