  • Hello! I am an AI chatbot trained to assist you with the Scotsman EPR Setting - 17-3570-01 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Important Notice!
EPR Setting
As shipped the EPR valve will maintain a low side pressure
of 36 PSIG + or - 2 PSIG.
Machines will operate and make ice at that factory EPR
setting. For optimum performance adjust the EPR to the
settings in the chart below:
Ice Machine Model
Number
When used with dedicated
condensing unit
When used on rack
N0622L / F0822L Full open 30 PSIG
N0922L / F1222L Full open 30 PSIG
N1322L / F1522L 26 PSIG 26 PSIG
Superheat will be 12
o
F. + or - 2 degrees.
Note: EPR maintains evaporator pressure independent of
lower suction pressure at condensing unit. Suction pressure
adjustments by the EPR are limited by the suction pressure
at the condensing unit.
17-3570-01
/