Datalogic Hand-held devices II Configuration manual

Category
Bar code readers
Type
Configuration manual
Hand-Held Devices II
Software Configuration Manual
Australia
Datalogic Scanning Pty Ltd
North Ryde, Australia
Telephone: [61] (2) 9870 3200
Fax: [61] (2) 9878 8688
France and Benelux
Datalogic Scanning Sarl
LES ULIS Cedex, France
Telephone: [33].01.64.86.71.00
Fax: [33].01.64 46.72.44
Germany
Datalogic Scanning GmbH
Darmstadt, Germany
Telephone: 49 (0) 61 51/93 58-0
Fax: 49 (0) 61 51/93 58 58
Italy
Datalogic Scanning SpA
Vimercate (MI), Italy
Telephone: [39] (0) 39/62903.1
Fax: [39] (0) 39/6859496
Japan
Datalogic Scanning KK
Shinagawa, Tokyo, Japan
Telephone: 81 (0)3 3491 6761
Fax: 81 (0)3 3491 6656
Latin America
Datalogic Scanning, Inc
Miami, Florida, USA
Telephone: (305) 591-3222
Fax: (305) 591-3007
Spain and Portugal
Datalogic Scanning Sarl
Sucursal en España
Madrid, Spain
Telephone: 34 91 746 28 60
Fax: 34 91 742 35 33
United Kingdom
Datalogic Scanning LTD
Watford, England
Telephone: 44 (0) 1923 809500
Fax: 44 (0) 1923 809 505
www.scanning.datalogic.com
Datalogic Scanning, Inc.
959 Terry Street
Eugene, OR 97402
Telephone: (541) 683-5700
Fax: (541) 345-7140
©2007 Datalogic Scanning, Inc. 90ACC1877 (Rev. C)
09/07
Datalogic Scanning, Inc.
959 Terry Street
Eugene, Oregon 97402
Telephone: (541) 683-5700
Fax: (541) 345-7140
An Unpublished Work - All rights reserved. No part of the contents of this
documentation or the procedures described therein may be reproduced or
transmitted in any form or by any means without prior written per-mission of Datalogic
Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”).
Owners of Datalogic products are hereby granted a non-exclusive, revocable license
to reproduce and transmit this documentation for the purchaser's own internal
business purposes. Purchaser shall not remove or alter any proprietary notices,
including copyright notices, contained in this documentation and shall ensure that all
notices appear on any reproductions of the documentation.
Should future revisions of this manual be published, you can acquire printed versions
by contacting your Datalogic representative. Electronic versions may either be
downloadable from the Datalogic website (www.scanning.datalogic.com) or provided
on appropriate media. If you visit our website and would like to make comments or
suggestions about this or other Datalogic publications, please let us know via the
"Contact Datalogic" page.
Disclaimer
Datalogic has taken reasonable measures to provide information in this manual that
is complete and accurate, however, Datalogic reserves the right to change any
specification at any time without prior notice. Datalogic is a registered trademark of
Datalogic S.p.A. in many countries and the Datalogic logo is a trademark of Datalogic
S.p.A. all licensed to Datalogic Scanning, Inc. All other trademarks and trade names
referred to herein are property of their respective owners.
iii
CONTENTS
1
INTRODUCTION .......................................................................................... 1
2 INITIAL SETUP ............................................................................................ 3
3 CONFIGURATION...................................................................................... 12
USB PARAMETERS .................................................................................. 13
Handshaking............................................................................................... 14
Ack/Nack Protocol....................................................................................... 14
Fifo.............................................................................................................. 15
Inter-character Delay .................................................................................. 15
Rx Timeout.................................................................................................. 16
Serial Trigger Lock...................................................................................... 16
Keyboard Nationality................................................................................... 17
Fifo.............................................................................................................. 18
Inter-character Delay .................................................................................. 18
Inter-code Delay.......................................................................................... 18
Control Character Emulation....................................................................... 19
RS232 PARAMETERS............................................................................... 20
Baud Rate................................................................................................... 21
Parity........................................................................................................... 22
Data Bits ..................................................................................................... 22
Stop Bits...................................................................................................... 23
Handshaking............................................................................................... 23
Ack/Nack Protocol....................................................................................... 24
Fifo.............................................................................................................. 24
Inter-character Delay .................................................................................. 25
Rx Timeout.................................................................................................. 25
Serial Trigger Lock...................................................................................... 26
WEDGE PARAMETERS ............................................................................ 27
Keyboard Nationality................................................................................... 29
Caps Lock................................................................................................... 30
Caps Lock Auto-Recognition (IBM AT compatible only) .............................. 30
Num Lock.................................................................................................... 31
Inter-character Delay .................................................................................. 31
Inter-code Delay.......................................................................................... 32
Control Character Emulation....................................................................... 32
Keyboard Setting ........................................................................................ 33
PEN EMULATION ...................................................................................... 35
Operating Mode .......................................................................................... 36
iv
Minimum Output Pulse................................................................................ 37
Conversion to Code 39 ............................................................................... 38
Overflow...................................................................................................... 38
Output Level................................................................................................ 39
Idle Level..................................................................................................... 39
Inter-Block Delay......................................................................................... 40
IBM 46xx .................................................................................................... 41
IBM Data Formatting................................................................................... 42
DATA FORMAT.......................................................................................... 43
Code Identifier............................................................................................. 46
Custom Code Identifier ............................................................................... 47
Header ........................................................................................................ 48
Terminator................................................................................................... 49
Field Adjustment ......................................................................................... 50
Field Adjustment Character......................................................................... 51
Code Length Tx .......................................................................................... 51
Character Replacement .............................................................................. 53
POWER SAVE............................................................................................ 56
Scan Rate ................................................................................................... 57
Sleep State/USB Suspend.......................................................................... 57
Enter Sleep Timeout ................................................................................... 58
Standby....................................................................................................... 58
READING PARAMETERS ......................................................................... 59
Hand-Held Operation .................................................................................. 60
Stand Operation.......................................................................................... 60
Hardware Trigger Signal ............................................................................. 61
Trigger-off Timeout ..................................................................................... 61
Flash Mode ................................................................................................. 62
Reads per Cycle ......................................................................................... 62
Safety Time................................................................................................. 63
Beeper Intensity .......................................................................................... 63
Beeper Tone ............................................................................................... 64
Beeper Type ............................................................................................... 64
Beeper Length ............................................................................................ 64
Good Read Spot Duration........................................................................... 65
Stand Recognition Beep ............................................................................. 65
Automatic Operation Aiming Light............................................................... 66
Aiming System ............................................................................................ 66
DECODING PARAMETERS....................................................................... 67
Ink Spread................................................................................................... 68
Overflow Control ......................................................................................... 68
Interdigit Control.......................................................................................... 69
v
Decoding Safety.......................................................................................... 69
Puzzle Solver™ .......................................................................................... 70
CODE SELECTION .................................................................................... 71
EAN/UPC Family ........................................................................................ 73
2/5 Family ................................................................................................... 77
Code 39 Family........................................................................................... 78
Code 128 Family......................................................................................... 80
Code 93 ...................................................................................................... 81
Codabar Family........................................................................................... 82
MSI ............................................................................................................. 84
Plessey ....................................................................................................... 85
Telepen ....................................................................................................... 86
Delta IBM .................................................................................................... 87
Code 11 ...................................................................................................... 88
Code 16K.................................................................................................... 89
Code 49 ...................................................................................................... 89
RSS Codes ................................................................................................. 90
ADVANCED FORMATTING....................................................................... 91
Concatenation............................................................................................. 92
Advanced Formatting.................................................................................. 95
4 REFERENCES ......................................................................................... 113
A HOST CONFIGURATION STRINGS .......................................... 129
B CODE IDENTIFIER TABLE......................................................... 141
C HEX AND NUMERIC TABLE ................................................................... 139
vi
CONFIGURATION METHODS
Reading Configuration Barcodes
If you wish to change the default settings, this manual provides complete
configuration of your reader in an easy way:
To configure your reader:
1) Open the folded page in Appendix C with the hex-numeric table and keep it
open during the device configuration.
2) Read the Enter Configuration code ONCE, available at the top of each page
of configuration.
3) Modify the desired parameters in one or more sections following the
procedures given for each group.
4) Read the Exit and Save Configuration code ONCE, available at the top of
each page of configuration.
Reference notes describing the operation of the more complex parameters are given
in chapter 4.
Using DL Sm@rtSet
DL Sm@rtSet is a Windows-based utility program providing a quick and user-friendly
configuration method via the RS232 or USB-COM interfaces.
It also allows upgrading the software of the connected device (see the DL Sm@rtSet
User’s Manual for more details).
Copy Command
A previously configured reader (Master device), can be used to send its configuration
directly to other readers of the same type. The particular procedure for each device is
given in par. 4.9.
vii
Sending Configuration Strings from Host
An alternative configuration method is provided in Appendix A using the RS232 or
USB interfa
ces. This method is particularly useful when many devices need to be
configured with the same settings. Batch files containing the desired parameter
settings can be prepared to configure devices quickly and easily.
viii
INTRODUCTION
1
1 INTRODUCTION
This manual provides all the necessary information for complete software
configuration of various Datalogic families of second generation Hand-Held Devices
(HHD II), including CCD guns and readers and laser scanners.
Your reader contains a built-in decoder
and multi-standard interface.
It is designed for use in a wide variety of applications and environments including
commercial, office automation, retail, and light industrial applications where
large quantities of information need to be collected rapidly, easily and reliably.
It has several status indicator functions which are described in the next paragraph.
HHD II
2
1.1 STATUS INDICATORS
Several status indicators are available depending on the type of reader: LEDs,
Beeper, and Good Read Spot (for CCD Long Range readers only). They signal
several operating conditions which are described in the tables below.
H = high tone L = low tone
READER START-UP
Beeper
1
Meaning
L L L L Parameters loaded correctly
H H H H
long tones
Parameter loading error, reading or writing error in the non volatile
memory
H L H L Hardware error in EEPROM
OFF No beeper performed when illuminator line is kept high at power on.
READER CONFIGURATION
Beeper
1
Meaning
H H H H correct entry in Configuration mode
L good read of a command
L L L command read error
L H H H H exit from Configuration mode
READER DATA ENTRY
Beeper
1
LED Good Read Spot Meaning
one beep
2
ON ON correct read of a code in normal mode
OFF OFF ready to read a code
1
only the Beeper Intensity command can modify these signals.
2
the data entry good read tone is user-configurable with all the Beeper commands in the
Reading Parameters section.
INITIAL SETUP
3
2 INITIAL SETUP
2.1 INTERFACE SELECTION
Follow the procedure to configure the interface required by your application
USB Interface
RS232 Interface
Wedge Interface
Pen Emulation Interface
IBM 46xx Interface
2.1.1 USB Interface Configuration
The USB interface is compatible with:
- Windows 98 (and later)
- Mac OS 8.0 (and later)
- IBM POS for Windows
- 4690 Operating System
The USB interface is compatible with:
Windows 98 (and later) IBM POS for Windows
Mac OS 8.0 (and later) 4690 Operating System
START-UP
As with all USB devices, upon connection, the Host performs several checks by
communicating with the USB device. During this phase the LED on the device blinks
and normal operations are suspended. Two basic conditions must be met before the
USB device is ready to read codes, the correct USB driver must be loaded and
sufficient power must be supplied to the reader
.
For all systems, the correct USB driver for the default USB-KBD interface is included
in the Host Operating System and will either be loaded automatically or will be
suggested by the O.S. and should therefore be selected from the dialog box (the first
time only).
If the Host supplies sufficient power to the reader, the start-up phase ends correctly,
the LED stops blinking and the reader emits the beep OK signal.
HHD II
4
If the Host does not supply sufficient power to the reader, a dialog box will appear on
the Host and the reader will be blocked (LED continues blinking). In this case,
disconnect the USB device cable at the Host (LED stops blinking), connect and
power-up an external supply to the USB device cable then
reconnect the USB device
cable to the Host and close the dialog box. The reader emits the beep OK signal.
You can now read codes. At this point you can read the USB interface configuration
code according to your application. Load drivers from the O.S. (if requested). When
configuring the USB-COM interface, the relevant files and drivers must be installed
from the USB Device Installation software which can be downloaded from the web
site: http://www.scanning.datalogic.com.
The reader is ready.
Connect device to
Host with USB cable
Does a dialog
box appear
asking whether
Bus power is
sufficient?
Select desired
USB interface
code
Disconnect reader
at Host
Connect external
power supply to
cable and power up
Reconnect reader
cable to Host and
close dialog box
NO
YES
Read test codes.
Reader is READY
Load drivers
(if requested)
Load drivers
(
if re
q
uested
)
LED blinks
LED off - BEEP OK
BEEP OK
First Start-Up
LED off
INITIAL SETUP
5
Successive start-ups will automatically recognize the previously loaded drivers. If
external power is used, verify that external power is already supplied.
NO
YES
Read test codes.
Reader is READY
LED blinks
LED off - BEEP OK
BEEP OK
Connect device to
Host with USB cable
Successive Start-Ups
Disconnect reader
at Host
Connect external
power supply to
cable and power up
Reconnect reader
cable to Host and
close dialog box
Does a dialog
box appear
asking whether
Bus power is
sufficient?
HHD II
6
USB INTERFACE
USB-KBD
Ì$+UA03$-:Î
USB-KBD-ALT-MODE
Ì$+UA04$-@Î
USB-KBD-APPLE
Ì$+UA05$-FÎ
USB-COM*
Ì$+UA02$-4Î
USB-IBM-Table Top
Ì$+UA00$-(Î
USB-IBM-Hand Held
Ì$+UA01$-.Î
* When configuring USB-COM, the relevant files and drivers must be installed from
the USB Device Installation software which can be downloaded from the web site:
(see http://www.scanning.datalogic.com).
INITIAL SETUP
7
2.1.2 RS232 Interface Selection
Read the restore default code, then read the interface selection code for your
application:
RESTORE DEFAULT
Ì$+$*oÎ
RS232 INTERFACE
Standard
Ì$+CP0$-$Î
POS SYSTEMS
Nixdorf Mode A
Ì$+CM2EC0$->Î
Fujitsu
Ì$+CM1$-ÈÎ
ICL Mode
Ì$+CM0$-ÃÎ
For POS system default settings refer to par. 4.10.
HHD II
8
2.1.3 Wedge Interface Selection
Read the restore default code, then read the interface selection code for your
application:
RESTORE DEFAULT
Ì$+$*oÎ
WEDGE INTERFACE
IBM AT or PS/2 PCs
Ì$+CP500$-aÎ
IBM XT
Ì$+CP503$-vÎ
PC Notebook
Ì$+CP505$-ÈÎ
IBM SURE1
Ì$+CP506$-$Î
IBM Terminal 3153
Ì$+CP504$-}Î
INITIAL SETUP
9
WEDGE INTERFACE (CONTINUED)
IBM Terminals 31xx, 32xx, 34xx, 37xx:
To select the interface for these IBM Terminals, read the correct KEY
TRANSMISSION code. select the KEYBOARD TYPE if necessary (default =
advanced keyboard).
KEY TRANSMISSION MODE
make-only keyboard
Ì$+CP502$-oÎ
make-break keyboard
Ì$+CP501$-hÎ
KEYBOARD TYPE
advanced keyboard
Ì$+FK1$-ÉÎ
typewriter keyboard
Ì$+FK0$-ÄÎ
ALT MODE
The following interface selection allows barcodes sent to the PC to be interpreted
correctly independently from the Keyboard Nationality used. You do not need to
make a Keyboard Nationality selection.
(default = Num Lock Unchanged). Make sure the Num Lock key on your
keyboard is ON.
IBM AT - ALT mode
Ì$+CP507$-+Î
PC Notebook - ALT mode
Ì$+CP508$-2Î
HHD II
10
WEDGE INTERFACE (CONTINUED)
WYSE TERMINALS
ANSI Keyboard
Ì$+CP509$-9Î
PC Keyboard
Ì$+CP510$-gÎ
ASCII Keyboard
Ì$+CP511$-nÎ
VT220 style Keyboard
Ì$+CP514$-ÇÎ
DIGITAL TERMINALS
VT2xx/VT3xx/VT4xx
Ì$+CP512$-uÎ
APPLE
APPLE ADB Bus
Ì$+CP513$-|Î
INITIAL SETUP
11
2.1.4 Pen Emulation Interface Selection
Read the restore default code, then read the Pen Emulation interface selection code.
RESTORE DEFAULT
Ì$+$*oÎ
PEN EMULATION
Ì$+CP6$-BÎ
2.1.5 IBM 46xx Interface Selection
(IBM Devices only)
PORT 9B
4501 Protocol
Ì$+CP800$-pÎ
(typical)
1520 Protocol
Ì$+CP801$-wÎ
PORT 5B
1520 Protocol
Ì$+CP801$-wÎ
(typical)
4501 Protocol
Ì$+CP800$-pÎ
HHD II
12
3 CONFIGURATION
Once your reader is setup, you can change the default parameters to meet your
application needs. Refer to chapter 2 for initial configuration in order to set the default
values and select the interfac
e for your application.
In this manual, the configuration parameters are divided into logical groups making it
easy to find the desired function based on its reference group.
The first four groups are for Standard Interface parameter configuration, the fifth is
only for IBM 46xx models:
USB
RS232
WEDGE
PEN EMULATION
IBM 46xx
The following parameter groups are common to all interface applications:
DATA FORMAT parameters regard the messages sent to the Host system for all
interfaces except Pen Emulation.
POWER SAVE manages overall current consumption in the reading device.
READING PARAMETERS control various operating modes and indicator status
functioning.
DECODING PARAMETERS maintain correct barcode decoding in certain special
reading conditions.
CODE SELECTION parameters allow configuration of a personalized mix of codes,
code families and their options.
ADVANCED FORMATTING PARAMETERS allow code concatenation and
advanced formatting of messages towards the Host. It cannot be used with Pen
Emulation.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155

Datalogic Hand-held devices II Configuration manual

Category
Bar code readers
Type
Configuration manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI