Rheem Professional Classic Series: Power Vent User manual

Category
Water heaters & boilers
Type
User manual

!
FOR YOUR SAFETY!
 Do not store or use gasoline or other
flammable vapors or liquids or other
combustible materials in the vicinity of this or
any other appliance. To do so may result in an
explosion or fire.
 WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas suppliers
instructions.
If you cannot reach your gas supplier, call
the fire department.
Do not return to your home until authorized
by the gas supplier or fire department.
Improper installation, adjustment, alteration,
service or maintenance can cause property
damage, personal injury, or death. Refer to
this manual. Installation and service must be
performed by a qualified installer, service
agency or the gas supplier.
WARNING: If the information in these instructions is not followed exactly,
a fire or explosion may result causing property damage, personal injury or death.
!












Do not destroy this manual. Please read carefully and keep in a safe place for
future reference.
!
Recognize this symbol as an indication of Important Safety Information!
!
California Proposition 65 Warning:




Printed in USA

D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
®
!
Warning: This water heater is not
suitable for use in manufactured (mobile) homes!
®
FVIR Certified


Care and Cleaning
 
 
 
 
 
Safety Information
 
  
Installation Instructions
 
 
 
 
 
 
 
 
  
 
 
Operating Instructions
 
  
Troubleshooting Tips

 
Customer Service
 
 



Staple sales slip or cancelled check here.









Your safety and the safety of others are very important. There
are many important safety messages in this manual and on your
appliance. Always read and obey all safety messages.
!
This is the safety alert symbol. Recognize this symbol
as an indication of Important Safety Information!
This symbol alerts you to potential hazards that can
kill or hurt you and others.
All safety messages will follow the safety alert symbol and
either the word “DANGER”, “WARNING”, “CAUTION” or
“NOTICE”.
These words mean:
!
DANGER
An imminently hazardous situation
that will result in death or serious
injury.
!
WARNING
A potentially hazardous situation that
could result in death or serious injury
and/or damage to property.
!
CAUTION
A potentially hazardous situation that
may result in minor or moderate
injury.
Notice:
Attention is called to observe a
specified procedure or maintain
a specific condition.

Be sure to read and understand the entire Use and Care Manual before attempting to install or operate this water
heater. It may save you time and money. Pay particular attention to the Safety Instructions. Failure to follow these
warnings could result in serious bodily injury or death. Should you have problems understanding the instructions in
this manual, or have any questions, STOP, and get help from a qualified service technician, or the local gas utility.


Failure to install the blower assembly and properly vent the water heater to the outdoors
as outlined in the Venting Section of the Installation Instructions in this manual can result
in unsafe operation of the water heater. To avoid the risk of fire, explosion, or asphyxiation
from carbon monoxide, never operate this water heater unless it is properly vented and
has an adequate air supply for proper operation. Be sure to inspect the vent system for
proper installation at initial start-up; and at least annually thereafter. Refer to the Care and
Cleaning section of this manual for more information regarding vent system inspection.


Gasoline, as well as other flammable materials and liquids (which include but are not
limited to adhesives, solvents, paint thinners etc.), and the vapors they produce are
extremely dangerous. DO NOT handle, use or store gasoline or other flammable or
combustible materials anywhere near or in the vicinity of a water heater or any other
appliance. Be sure to read and follow warning label pictured below and other labels on the
water heater, as well as the warnings printed in this manual. Failure to do so can result in
property damage, bodily injury or death.
!
!
FLAMMABLES
Flammable Vapors
FIRE AND EXPLOSION HAZARD
Can result in serious injury or death.
Do not store or use gasoline or other flammable vapors and liquids
in the vicinity of this or any other appliance. Storage of or use of gasoline
or other flammable vapors or liquids in the vicinity of this or any other
appliance can result in serious injury or death.
W A R N I N G
NOTICE: This water heater is equipped with a flammable vapor sensor that will automatically shut
down the water heater in the presence of gasoline vapors and some other flammable vapors. If the
flammable vapor sensor shuts down the water heater, contact a qualified service technician. Clear any
hazardous materials and ventilate the area around the water heater. Do not turn off the appliance
or adjust the ON/OFF switch in any way. Do not tamper with the flammable vapor sensor. Do not
submerse the flammable vapor sensor in water. Do not allow the flammable vapor sensor to come into
contact with any substances such as bleach or cleaners. See the “Gas Valve LED Error Code” Section
of this manual for a list of error codes.
Time/Temperature Relationship in Scalds
 
120°F More than 5 minutes
125°F 1
1
/2 to 2 minutes
130°F About 30 seconds
135°F About 10 seconds
140°F Less than 5 seconds
145°F Less than 3 seconds
150°F About 1
1
/2 seconds
155°F About 1 second




DANGER: Households with small children, disabled,
or elderly persons may require a 120°F or lower gas control
(thermostat) setting to prevent contact with “HOT” water.
















D A N G E R
!
HOT
Water temperature over 125°
can
cause severe burns
instantly or
death from scalds.
Children, disabled and elderly are
at highest risk of being scalded.
See instruction manual before
setting temperature at water
heater.
Feel water before bathing or
showering.
Temperature limiting valves are
available, see manual.
BURN
F (52°C)
!

Safety and energy conservation are factors to be considered when selecting the water
temperature setting of a water heater’s gas control. Water temperatures above 125°F
can cause severe burns or death from scalding. Be sure to read and follow the warnings
outlined on the label pictured below. This label is also located on the water heater.
Notice: Mixing valves are available for reducing point
of use water temperature by mixing hot and cold water
in branch water lines. Contact a licensed plumber or the
local plumbing authority for further information.


!






 
 
 
 

 
 
 
 

 
!
DANGER: Hotter
water increases the
potential for Hot Water
SCALDS.
LP and Natural gas have an odorant added to aid in detecting a gas leak. Some people
may not physically be able to smell or recognize this odorant. If you are unsure or
unfamiliar with the smell of LP or natural gas, ask the gas supplier. Other conditions,
such as “odorant fade”, which causes the odorant to diminish in intensity, can also hide or
camouflage a gas leak.


Water heaters utilizing LP gas are
different from natural gas models. A
natural gas water heater will not function
safely on LP gas and vice versa.
No attempt should ever be made to
convert the water heater from natural
gas to LP gas. To avoid possible
equipment damage, personal injury or
fire, do not connect the water heater to a
fuel type not in accordance with the unit
data plate. LP for LP units. Natural gas
for natural gas units. These units are not
certified for any other fuel type.
LP appliances should not be installed
below grade (for example, in a basement)
if such installation is prohibited by
federal, state and/or local laws, rules,
regulations or customs.
LP gas must be used with great caution.
It is heavier than air and will collect first
in lower areas making it hard to detect at
nose level.
Before attempting to light the water
heater, make sure to look and smell for
gas leaks. Use a soapy solution to check
all gas fittings and connections. Bubbling
at a connection indicates a leak that must
be corrected. When smelling to detect a
gas leak, be sure to sniff near the floor
also.
Gas detectors are recommended in LP
& natural gas applications and their
installation should be in accordance
with the detector manufacturer’s
recommendations and/or local laws,
rules, regulations or customs.
It is recommended that more than one
method, such as soapy solution, gas
detectors, etc., be used to detect leaks in
gas applications.
!
DANGER: If a gas leak is present or
suspected:
Donotattempt to find the cause
yourself.
Donot try to light any appliance.
Donot touch any electrical switch.
Donot use any phone in your building.
Leave the house immediately and make
sure your family and pets leave also.
Leave the doors open for ventilation
and contact the gas supplier, a qualified
service agency or the fire department.
Stay away from the house (or building)
until the service call has been made, the
leak is corrected and a qualified agency
has determined the area to be safe.


!
For your safety, the information in this manual must be followed to minimize the risk of
fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of
life.

California Law requires that residential water heaters must be braced, anchored or
strapped to resist falling or horizontal displacement due to earthquake motions. For
residential water heaters up to 52-gallon capacity, a brochure with generic earthquake
bracing instructions can be obtained from: Office of the State Architect, 1102 Q Street,
Suite 5100, Sacramento, CA 95814 or you may call 916-445-8100 or ask a water heater
dealer.
However, applicable local codes shall govern installation. For residential water heaters
of a capacity greater than 52 gallons, consult the local building jurisdiction for acceptable
bracing procedures.











Do not 










Installing the water heater.
This water heater must be installed in accordance with these instructions, local codes, utility company
requirements, and/or in the absence of local codes, use the latest edition of the American National
Standard/National Fuel Gas Code. A copy can be purchased from either the American Gas Association,
400 N. Capitol Street NW, Washington, DC 20001 as ANSI standard Z223.1 or National Fire Protection
Association, 1 Batterymarch Park, Quincy, MA 02269 as booklet NFPA 54.
Location
The water heater should not be located
in an area where leakage from the tank
or connections will result in damage
to the area adjacent to the heater or to
lower floors of the structure.
When such areas cannot be avoided it is
recommended that a suitable catch pan,
adequately drained, must be installed
under the water heater.
The water heater must be centered in
the catch pan.
The catch pan must not restrict air
flow to the combustion air inlet openings
(perforation openings) located around the
lower perimeter of the water heater.
Catch pan kits are available from
the store where the water heater
was purchased, or any water heater
distributor.











DO NOT block or obstruct any of the
combustion air inlet openings located
around the perimeter of the water
heater. A minimum of 1” is required
between these combustion air inlet
openings and any obstruction.
DO NOT obstruct or block the
Flammable Vapor Sensor.
































DO NOT























The auxiliary catch pan
installation MUST conform
to local codes.





!
WARNING: Combustible
construction refers to
adjacent walls and ceilings
and should not be confused
with combustible or
flammable products and
materials. Combustible
and/or flammable products
and materials should never
be stored in the vicinity of
this or any gas appliance.
Front Sides Rear Top








Notice: DO NOT allow
the flammable vapor
sensor to become
submerged in water.
Make sure the catch pan
is properly drained.



Notice: DO NOT allow
the catch pan to obstuct
the flammable vapor
sensor.
Installing the water heater.
Combustion and Ventilation Air
Ventilation (ambient) air temperature
must be 100°F or less. Proper operation
of the water heater requires air for
combustion and ventilation. Provisions
for combustion and ventilation air
must comply with referenced codes and
standards.
DO NOT block or obstruct any of the
combustion air inlet openings located
around the perimeter of the water
heater. A minimum of 1” is required
between these combustion air inlet
openings and any obstruction.
NOTICE: If the water heater is
installed in an unconfined space within a
building of conventional frame, masonry
or metal construction, infiltration
air is normally adequate for proper
combustion and ventilation. If the
water heater is installed in a confined
space, provisions for combustion and
ventilation air must be made.
DO NOT





































NOTICE: If the duct openings which
supply combustion and ventilation air
are to be covered with a protective
screen or grill, the net free area
(openings in the material) of the
covering material must be used in
determining the size of the openings.
Protective screening for the openings
MUST NOT be smaller than 1/4”mesh
to prevent clogging by lint or other
debris.
Corrosive Atmospheres



















NOTICE: The water heater
should not be installed near
an air supply containing
halogenated hydrocarbons.
Inspect Shipment



NOTICE: Do not install the
water heater in attics where
the temperature may exceed
100°F. This water heater is
equipped with a temperature
sensing device that will
shut off the water heater
if the maximum allowable
vent pipe temperature is
exceeded.
Thermal Expansion
Determine if a check valve exists in the inlet
water line. Check with your local water
utility company.




“closed
water system”

“open”



“thermal expansion”“open”




“closed water system”

 “thermal
expansion”









will not






















Water Supply Connections
IMPORTANT: Do not apply
heat to the HOT or COLD
water connections. If sweat
connections are used, sweat
tubing to adapter before
fitting adapter to the cold
water connections on heater.
Any heat applied to the cold
water supply fittings will
permanently damage the
dip tube and heat traps.
NOTICE: The National
Fuel Gas Code (NFGC)
mandates a manual
gas shut-off valve: See
(NFGC) for complete
instructions. Local codes
or plumbing authority
requirements may vary
from the instructions or
diagrams provided and
take precedent over these
instructions.
Vacuum Relief Valve
(Not Supplied)
If required, install per local codes
and valve manufacturer’s
instructions.










































Typical Installation





Installing the water heater.
A new combination temperature and pressure relief valve, complying with the Standard for Relief Valves
and Automatic Gas Shut-Off Devices for Hot Water Supply Systems, ANSI Z21.22, is supplied and must
remain in the opening provided and marked for the purpose on the water heater. No valve of any type
should be installed between the relief valve and the tank. Local codes shall govern the installation of
relief valves.
Relief Valve






















To Fill the Water Heater










WARNING: The tank
must be full of water before
heater is turned on. The
water heater warranty does
not cover damage or failure
resulting from operation
with an empty or partially
empty tank.
Condensation












WARNING: Do not attempt to convert this water heater for use with a different type of gas other than the type
shown on the rating plate. Such conversion could result in hazardous operating conditions.
Leak Testing













High Altitude
















Pressure Testing the Gas Supply System














Gas Supply












































WARNING: Never use
an open flame to test for
gas leaks, as property
damage, personal injury, or
death could result.
WARNING: Failure to
install a water heater
suitable for the altitude at
the location it is intended to
serve, can result in improper
operation of the appliance
resulting in property
damage and/or producing
carbon monoxide gas, which
could result in personal
injury, or death.

Installing the water heater.
The water heater must be installed with the factory supplied blower assembly in place.
Venting



































































NOTICE: The vent piping must be
connected to the blower assembly
using the rubber coupling and supplied
clamps. The vent pipe connections at
the blower assembly must be leak tested
with soap and water solution upon
initial startup. Repair any leaks before
allowing the water heater to operate.
DANGER: Failure to
install the blower assembly
and properly vent the water
heater to the outdoors as
outlined in the Venting
section of this manual will
result in unsafe operation of
the water heater causing
bodily injury, explosion,
fire or death.
To avoid the risk of fire,
explosion, or asphyxiation
from carbon monoxide,
NEVER operate the water
heater unless it is properly
vented and has adequate air
supply for proper operation
as outlined in the Venting
section of this manual.
The vent pipe must overlap
a minimum of ½” on each
connection. It is important
that the vent pipe engages
fully into any pipe fitting
and be kept in that position
until the adhesive has fully
cured. DO NOT drill or
punch holes in the plastic
pipe or fittings.
NOTICE: This unit is
equipped with a Flammable
Vapor Sensor. Do not
apply power until enough
time has passed to allow the
vapors from the primer and
cement to dissipate.
Blower Assembly Installation




Do not overtighten screws to ensure plastic does not crack.
NOTICE:


Additional installation information for The
Commonwealth of Massachusetts is located
on the back page of this manual.
Flue
Baffle
Rubber
Coupling
Blower
Assembly

Maximum and Minimum Vent Lengths for Residential
40 & 50 Gallon Power Vents
NOTICE: The mixing of 2" and
3" vent pipe is not recommended.
If 3" pipe is used, a 2" to 3"
reducer fitting is recommended at
the rubber coupling.







Models
Maximum
Altitude for
2” & 3” Vents










Minimum Vent Restrictor






DO NOT 















   
   
   
   
   
   
   
   
   


Minimum vent length for 3” vent pipe is one (1) foot of vertical pipe, one
(1) 90°elbow, and four (4) feet of horizontal pipe.
Maximum Venting information for 3” Vents**
Maximum Venting information for 2” Vents*


Minimum vent length for 2”vent pipe is one (1) foot (30.4 cm)of vertical
pipe, one (1) 90°elbow, and three (3) feet (0.91 m) of horizontal pipe.
















 
 
 
 
 
 
 
 


 

Installing the water heater.
Additional Considerations


















If soffit vent is too
close, block off and
install new vent at
another location
Inside
corner
Caulk
Caulk
Caulk
6' (1.83 m)
caulk
zone or to edge of
window etc., starting
within 6'
Rising moisture will
collect under eaves
4'
6' caulk zone
2 ft. sq. sheet metal plate on
brick or masonary surface is recomended.
6'
WARNINGMoisture in the flue gas will condense as it
leaves the vent terminal. In cold weather this condensate can
freeze on the exterior wall, under the eaves and on
surrounding objects. Some discoloration to the exterior of
the building is to be expected. However, improper location
or installation can result in severe damage to the structure
or exterior finish of the building
Horizontal Vent Terminal Location

















4'
4'
Soffit vents
18"
4'
4'
4'
18"
Electric
meter
Inside
corner
3' above
if within 10'
Fresh
air
intake
12" (Above grade/snow level)
window or vent
NOTICE: All pipe, fittings, solvent cement, primers and procedures must conform to American
National Standards Institute and American Society for Testing and Materials (ANSI/ASTM) standards.



NOTICE: All pipe, fittings, solvent cement, primers and procedures must conform to American
National Standards Institute and American Society for Testing and Materials (ANSI/ASTM) standards.
Vertical Vent Installation





















Vertical Vent Termination Location
























Horizontal Vent Installation




























Installing the water heater.



































NOTICE: Stir the solvent cement
frequently while using. Use a natural
bristle brush or the dauber supplied
with the can. The proper brush size is
one inch.
NOTICE: This unit is equipped with a
Flammable Vapor Sensor. Do not apply
power until enough time has passed to
allow the vapors from the primer and
cement to dissipate.
Cementing Joints
WARNING: DANGER
OF FIRE OR BODILY
INJURY - Solvent cements
and primers are highly
flammable. Provide
adequate ventilation and do
not assemble near heat
source or open flame. Do not
smoke. Avoid skin or eye
contact. Observe all cautions
and warnings on material
containers.
CAUTION:
For proper installation:
DO NOT use solvent cement
that has become curdled,
lumpy or thickened.
DO NOT thin solvent
cement. Observe shelf
precautions printed on the
containers.
For applications below 32°F
use only low temperature
type solvent cement.
Appropriate solvent and
cleaner must be used for the
type of vent pipe used (PVC,
CPVC or ABS).
NOTICE: All pipe, fittings, solvent cement, primers and procedures must conform to American
National Standards Institute and American Society for Testing and Materials (ANSI/ASTM) standards.
Diagram Without Optional Electronic Display
1
H
H
N
N
PRESSURE
SWITCH
TEMPERATURE
SWITCH
SPARK
P1
P3
P2
E1
GND
120
PILOT
ELECTRODE
ASSY
PS
TS
TS1
TS2
FV
MOT
1
2
3
4
5
1
2
3
1
1
2
SCHEMATIC
CONNECTION DIAGRAM
WV 4460E CONTROL
N
H
G
120 VAC
INDUCER
3 x 2 CONNECTOR
BL
R
Y
W
BK
G
5
4
3
2
1
<
>
BK = BLACK
BL = BLUE
G = GREEN
R = RED
W = WHITE
Y = YELLOW
1
2
W
W
TS2
BK
BK
TS1
FV
1
2
3
120 NEUT
GROUND
120 VAC



Wiring





















NOTE


Installing the water heater.
Diagram With Optional Electronic Display









Hot and Cold Pipe Insulation Installation
Insulation Blankets

























CAUTION: If local codes require the
application of an external insulation
blanket to this water heater, pay careful
attention to the following so as not to
restrict the proper function and
operation of the water heater:



























WARNING: If local
codes require external
application of insulation
blanket kits the
manufacturer’s instructions
included with the kit must
be carefully followed.
NOTICE: If pipe
insulation is used, ensure
that the thickness does
not exceed ½”. Insulation
thicker than ½” can
interfere with the Blower
Assembly Dilution Air
Holes.
Dilution Air
Intake
Typical vertical piping arrangement
Typical horizontal piping arrangement












!

















NOTICE: Do not over tighten to avoid cracking
plastic enclosure.

























Installing the Optional User Display













  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Rheem Professional Classic Series: Power Vent User manual

Category
Water heaters & boilers
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI