www.fmiproducts.com
111986-01K20
FIREPLACE INSTALLATION
Continued
Figure 27 - Location of Wiring Diagram
Decal (Model May Vary from Illustration)
Wiring Diagram
Decal 12" in Front
of Burner
9. Check to make sure power cord is com-
pletely clear of blower wheel and there are
no other foreign objects in blower wheel.
Turn blower on and check for operation.
Turn blower off by turning knob fully coun-
terclockwise before continuing.
10. Peel off backing paper and stick supplied
wiring diagram decal on rebox bottom
approximately 12" in front of blower (see
Figure 27).
Model BKT Installation
Note: When installing the BKT thermostatical-
ly-controlled blower, you must rst secure the
wiring connections from the thermal switch to
the blower (if it has not already been factory
installed).
1. Attach green ground wire from power cord
to blower housing using screw provided
(see Figure 28, page 21) Tighten screws
securely with a Phillips screwdriver.
2. Connect wire harness and power cord
terminals. Connect the jumper wire to
the blower motor terminal to the terminal
of the thermal switch. Connect one wire
of the thermal switch and one wire to the
other remaining blower motor terminal.
Note: The power cord outer insulation sleeve
may have to be stripped slightly to allow
enough wire length to reach and make all
connections. DO NOT trim excessive length
away. Just enable enough to make all con-
nections securely.
3. Place the blower against the lower rear
wall of the rebox outer wrapper with
the exhaust port directed upward. At-
tach Thermal disc magnetic bracket to
the bottom of the rebox sub-oor. The
thermodisc must be oriented near the
replace bottom as shown in Figure 28,
page 21, in order to sense temperature
and properly operate. The blower will be
held in position against the back wall by
the magnets incorporated onto the blower
housing (see Figure 28, page 21)
.
4. Be certain that all wire terminals are
securely attached to terminals on blower
motor and that the screw retaining the
green ground wire is tight.
5. Mount speed control box against mounting
plate provided in lower replace cavity by
placing plastic control shaft forward through
round hole (see Figure 26, page 19).
6. While supporting speed control, secure
control shaft with lock nut by pushing and
turning lock nut with pliers clockwise until
it is tight against mounting plate. Place
control knob provided on shaft (see Figure
26, page 19).
7. Check to make sure power cord is com-
pletely clear of blower wheel and that no
other foreign objects are in blower wheel.
Also double check all wire leads and make
sure wire routing is not pinched or in a
precarious position. Correct accordingly.
8. Turn on power to duplex outlet if previ-
ously turned off per warning in column 1,
page 19.
9. Plug in blower power cord to duplex outlet.
10. Blower will only run when speed control
knob is in ON position and thermal switch
senses temperature after replace begins
to heat up. Blower speed can be adjusted
by rotating control knob. To turn off, turn
knob fully counterclockwise until it clicks off.
If blower is ON and has been running with
replace operating, blower will continue to
run for a short time after replace has been
turned off. As thermal switch cools down,
blower shuts down automatically.
11. Peel off backing paper and stick supplied
wiring diagram decal on rebox bottom
approximately 12" in front of blower (see
Figure 27).