2.0 SETUP
2.1 UNPACKINGANDSETTINGUPYOURBALANCE
1) Removetheshippingprotectionscrewandroundcoverasshownbelowusing
theAllenkeysuppliedintheplasticbag.(Itisadvisabletokeeptheshipping
protection screw and the round cover along with the packing boxforusing
duringshippingtoanotherlocationinfuture).
Shippingprotectionscrew
Roundcoveraroundthescrew
2) Placethepan(whichcomesseparatelypacked)inthereceptaclesonthetop
cover.
Gentlyplacetheplasticpan
supportintothereceptacle
andsecurewiththescrew
suppliedintheplasticbag.
Becarefulwhenputtingthe
screwinthatyoudonot
usetoomuchforceasitcan
damagedtheloadcell.You
shouldjustbeabletouse
lightforcetosecurethe
screw.
3) Placethestainlesssteelpanontopoftheplasticpan.
4) Placethebalanceonafirmandflatsurfaceforaccurateweighing.
EN
© Adam Equipment 2016 4 308669539revB6-Mar17
2.2 INSTALLINGBATTERIES
Removethebatterycompartmentcoverandinsertsixbatteries(R6P/LR6/AAsize)
intothebatterycompartment.
2.3 OVERVIEW
DISPLAY/KEYBOARD
BEHIND
DCadaptersocket
Lockdownslot
TOP
StainlessSteelpan
PlasticPan
LCDdisplay
[On/Off]key
Turnsthebalance
poweron/off
[Unit]key
Changesweighing
units.Alsousedwhen
calibrating
[Tare]key
Setsdisplaytozeroor
taresthebalance
EN
© Adam Equipment 2016 5 308669539revB6-Mar17
BOTTOM
Batterycompartment
screws
Batterycompartment
cover
Batteriesarenot
included
DISPLAY
batteryindicator
ZEROindicator
Indicateswhenthe
balancezeroiscorrect.
STABLEindicator
Indicateswhenthe
readingisstable.
EN
© Adam Equipment 2016 6 308669539revB6-Mar17
2.4 LOCATING
ANDPROTECTINGYOURBALANCE
In order to keep your balance functioning at its best we suggest that you do the
following:
Avoidextremesoftemperature.Donotplaceindirect
sunlightornearairconditioningvents.
Makesurethebalanceislocatedonastrongtableandfree
fromvibration.
Avoidunstablepowersources.Donotoperatenearlarge
usersofelectricitysuchasweldingequipmentorlarge
motors.Donotleavebatteriesinthebalanceifyouarenot
usingitforalongtime.
Keepfreefromvibration.Donotplacenearheavyor
vibratingmachinery.
Avoidhighhumiditythatmightcausecondensation,and
keepawayfromdirectcontactwithwater.
Donotplacenearopenwindows,air‐conditioningventsor
fansthatmaycauseadraftandunstablereadings.
Keepthebalancesclean,anddonotstackmaterialonthe
balancewhenitisnotinuse.TheCorehasastackingfeature
allowingmorethanoneunittobestackedontopofeach
other.Formoredetailsonthisseethesectiononstoring.
EN
© Adam Equipment 2016 7 308669539revB6-Mar17
2.5 STORING
WHENNOTINUSE
IfyouhaveanyoftheHighland
TM
seriesorCoreBalance
TM
linesyoucanstorethem
easilyontopofeachother.Thishelpstosavespaceandprotectthemfromdamage.
WithoutShield WithShield
Note:Only4.7”/120mmøpansizemodelscanbestackedforstorage.Coremodels
with5.7”/145mmømaybestackedatthetopofthepilebutmachinescannotbe
stackedontopofthemduetothelargerpansize.
EN
© Adam Equipment 2016 8 308669539revB6-Mar17
3.0 BASICOPERATION
3.1 TURNINGONTHEBALANCE
PlugintheunitusingtheDCadapterorpowerfromthebatteries.
1) PresstheOn/OffbuttonandthebalancewillautomaticallyshowCqt-1.0 Cqt
thencountfrom0to9forafewseconds,andshowthevoltage X.X Volwhere
x.xisthevoltageofthebatteryortheDCadapter.Finallyitwilldisplay"0.00"
alongwiththelastselectedweighingunit,Stablesymbol,andZerosymbol.
2) Thebalanceisreadytobeused.
3) Toturnthebalanceoffafterusepressthe[on/off]keyagain.Thereisanauto
power‐offfunctionthatwillautomaticallyturntheunitoff,thiscanbesetin
theparameterssection.
3.2 ZEROING
/TARE
Youcanpressthe[Tare]keytosetanewzeropoint.Zerowillbesetifthereading
onthebalanceislessthan3%ofthebalancescapacity.Thismaybenecessaryifthe
weightisnotreadingzerowithnothingonthepan.Thezeroindicatorwillshowup
inthetopleftcorneroftheLCD.
Ifyouareusingacontainertoweighthenyoucanplacethisontheplatformand
press the [Tare] key, providing the container weight is more than 3% of the
maximumcapacityofthebalance,thedisplaywillshowzeroandNETwilllightupon
the display. You can then weigh your object in the container. Tared weight is
subtractedfromthetotalbalance’scapacity.
Note:Whenthecontainerisremovedanegativevaluewillbeshown.
Ifthebalancewastaredjustbeforeremovingthecontainer,thisvalue
isthegrossweightofthecontainerplusallitemsinsidethecontainer
whichwereremoved.
EN
© Adam Equipment 2016 9 308669539revB6-Mar17
3.3WEIGHING
Todeterminetheweightofasample,firsttareanemptycontainer(ifused),then
placethesampleinthecontainer.Thedisplaywillshowtheweightandtheunitof
weightcurrentlyinuse.Thestableindicatorwilllightupwhenthereadingisstable.
3.4
WEIGHINGUNITS
To change the weighing units, press [Unit] to cycle through the available units.
SeetheParametersectiontoenableordisabletheweighingunits.Oncetheunithas
beenselected,theweightwillbedisplayedintheselectedunitandasymbolforthe
weightwillbeshown.
EN
© Adam Equipment 2016 10 308669539revB6-Mar17
4.0 PARAMETERS
Thebalancehas3parametersthatcanbesetbytheuser.
FUNCTION SECTION DESCRIPTION
AutoOf
f
Seesection5.1 Setstheautopowerofffunction
Backlight
Seesection5.2 Setsthebacklight
OFF BLbacklightisoff
1 BLbacklightisautomatic
2 BLbacklightisalwayson
Weighingunit
Seesection5.3 Setsthe unitstobeused
kg–g–lb–oz–ct–dr–GN–N‐tl.t
4.1 AUTO
POWEROFF
The auto power off function helps conserve power when using the batteries or DC adapter.
The Auto switch-off time may be set up by the user and is the time after a period of
inactivity i.e. no weight movement or key presses.
1) Tosetthisparameterturnthepoweroff,pressandholdthe[Tare]keythen
pressthe[on/off]keyonce,thenreleasethe[Tare]key.
2) ThedisplaywillshowthefirstfunctionXXPWR, whereXXisthelastsetting.
3) Press[Tare]toselectthesettingsasfollows:
Off PWR
Autopowerof
f
10 PWR
10secondsbeforethepowerwillswitchof
f
20 PWR
20secondsbeforethepowerwillswitchof
f
30 PWR
30secondsbeforethepowerwillswitchof
f
40 PWR
40secondsbeforethepowerwillswitchof
f
50 PWR
50secondsbeforethepowerwillswitchof
f
60 PWR
60secondsbeforethepowerwillswitchof
f
70 PWR
70secondsbeforethepowerwillswitchof
f
80 PWR
80secondsbeforethepowerwillswitchof
f
90 PWR
90secondsbeforethepowerwillswitchof
f
4) Pressthe[Unit]keytoconfirmthesetting
5) Toexitturnthebalanceoffandbackonagain
EN
© Adam Equipment 2016 11 308669539revB6-Mar17
4.2 SETTINGTHEBACKLIGHT
Thebacklight maybeenabled ordisabledbythe user.Ifthebacklightisdisabled,
thebatterylifewillbegreater.
Thefollowingsettingsareavailable:
1 BL
Setsthebacklighttooperateautomaticallywhenaweightis
placedonthebalanceorakeyispressed.
2 BL
Setsthebacklighttobeonall the time.
OFF BL
Setsthebacklighttobeoff.
1) Tosetthisparameterturnthepoweroff,pressandholdthe[Tare]keythen
pressthe[on/off]keyonce,thenreleasethe[Tare]key.
2) ThedisplaywillshowthefirstfunctionPWR
3) Pressthe[Unit]keyuntilthedisplayshowsXX BL whereXXisthelastsetting
4) Press[Tare]keytoselectthesettingsasfollows1 BL‐2 BL–OFF BL
5) Pressthe[Unit]keytoconfirmthesetting
6) Toexitturnthebalanceoffandbackonagain
4.3 ENABLING
THEWEIGHINGUNITS
Youcanenableanddisabletheweighingunitsavailabletotheuserwhentheypress
the[Unit]keyasdescribedinsection4.4WeighingUnits.
1) Tosetthisparameterturnthepoweroff,pressandholdthe[Tare]keythen
pressthe[on/off]keyonce,thenreleasethe[Tare]key.
2) ThedisplaywillshowthefirstfunctionPWR
3) Press the [Unit] key until the display shows you XX g where XX is the last
settingonoroff.
4) Pressthe[Tare]keytoselectonoroFF.
5) Pressthe[Unit]keytomovetothenextweighingunit.
6) Repeatsteps5and6untilyouhavesetalloftheweighingunits.
EN
© Adam Equipment 2016 12 308669539revB6-Mar17
7) Toexitturnthebalanceoffandbackonagain
The following table shows the different weighing units which are available to the
userandtheconversionfactorsforeach.
Name of the
Units
Description Conversion
Factor
Display
Symbol
Kilograms Astandardmetricunit 0.001 Kg
Grams Astandardmetricunit 1.0 G
Pounds StandardweighingunitinUK/USA. 0.002205 Lb
Ounce Avoirdupoisounce.
16ouncesmakeapound.
0.03528 OZ
Carat Used
f
or weighing jewelry and gems,
etc.
5.0 ct
Dram Avoirdupois unit thereare 16DR in an
ounce.
0.564383 DR
Grains Abasicweighingunitintheimperial
system.Usedtoweighgunpowder.
15.432 GN
Newtons Usedtomeasureforce 0.009808 N
Taiwanese
taels
Usedtoweighcoral,pearls etc. 0.026666 Tl.t
EN
© Adam Equipment 2016 13 308669539revB6-Mar17
5.0 CALIBRATION
Calibrationmayberequiredwhenthebalanceisinitiallyinstalledormovedtoanew
location.Overtimeanduse,mechanicaldeviationsmayoccursoitisrecommended
thatyoucalibrateyoubalanceregularlyforpeakperformance.
Beforecalibratingyourshouldmakesureyouhavethecorrectweights.Theweights
shouldbeknowntoanaccuracythatisappropriateforthebalancebeingcalibrated,
forexample,OIMLClassM1typeorASTME617Class4.Ifyoudonothavethe
correctweightsdonotattemptcalibration.
Model CQT202 CQT251 CQT601 CQT1501 CQT2601 CQT2000 CQT5000
Calibration
Weight 100g
Or
200g
100g
Or
200g
200g
Or
400g
Or
600g
500g
Or
1000g
Or
1500g
1000g
Or
2000g
1000g
Or
2000g
1000g
Or
3000g
or
5000g
1) Tocalibratethebalanceapplypowerandswitchthebalanceon, whilstthe
displayiscyclingthroughit’stestroutinepressthe[Tare]and[Unit]keysat
thesametime,thenreleaseafter1second.
2) ThedisplaywillshowUnLOADremoveanyobjectsfromthepan.
3) Pressthe[Tare]keytoenterazerovalue.
4) The value last used for calibration will be displayed (see above table). To
selectadifferentcalibrationweight,pressthe[Unit]key.
5) Once you have selected the calibration weight to be used press the [Tare]
key.
6) LOADwillbedisplayed,placethecalibrationweightonthepan.
7) Oncethestablesignisshownpressthe[Tare]key.
8) Iftheweightiswithin5%ofthelastcalibrationvaluethedisplaywill show
PASS and exit the calibration mode. If the calibration is not successful the
displaywillshowFAILandexitthecalibrationmode,ifthecalibrationfailstry
itagain.
EN
© Adam Equipment 2016 14 308669539revB6-Mar17
6.0 TROUBLESHOOTING
6.1 ERRORMESSAGES
Ifanerrormessageisshown,repeatthestepthatcausedthemessage.Iftheerror
messageisstillshownthencontactyourdealerforsupport.
ERROR
CODE
DESCRIPTION POSSIBLECAUSES
Solutions
ADO
A/DValuetoohigh. Weightonthepanwhenturning
on.
Impropercalibrationofthe
balance.
Damagedloadcell.
DamagedElectronics.
Removeanyweight fromthe
stainlesssteelpan.
Recalibrate.
ADL
A/DValuetoolow. Panisnotinstalledwhenturning
on.
Calibrationnotcorrect.
Damagedloadcell.
Installpanandpowerback
on.
Recalibrate.
-----
A/Dcountisnotcorrect
whenturningthe
balanceon.
Loadcelldamaged.
Electronicsdamaged.
Removeanyweightfromthe
stainlesssteelpanandtry
rebooting.Trycalibratingthe
balance.
Unit-E
Uniterror. 
Lowbatteryindicator. Batteriesmaybeflat. Chargethebattery.
FAIL
Calibrationfailure. Incorrectmassusedtocalibrate.
Theusercalibrationisnotwithin
5%offactorycalibration.
Possibledamagedtoloadcell.
Trytorecalibrate,checkthat
theweightusedtocalibrate
matchesthatofthevalueof
thebalance.
Unstable–machine
cannotgetastable
reading.
PossibledamagetotheLoadcell. Makesurethebalanceisona
flatsurfaceandawayfrom
vibration.
NoPowerwhenturning
on.
Batterymaybeflat.DCadapter
maynotbeworking.
Changethebatteries.Oruse
theDCadapter
EN
© Adam Equipment 2016 15 308669539revB6-Mar17
6.2 REPLACEMENT
PARTSANDACCESSORIES
Ifyouneedtoorderanysparepartsandaccessories,contactyoursupplierorAdam
Equipment.Apartiallistofthemorecommonitemsfollows:
Part Number Description
7.00.4.0.0023 POWER SUPPLY STANDARD MODEL 12VDC 500mA - UK
7.00.4.0.0024 POWER SUPPLY STANDARD MODEL 12VDC 500mA - USA
7.00.4.0.0025 POWER SUPPLY STANDARD MODEL 12VDC 500mA - OZ
7.00.4.0.0026 POWER SUPPLY STANDARD MODEL 12VDC 500mA - EURO
7.00.4.0.0027 POWER SUPPLY STANDARD MODEL 12VDC 800mAa - SA
3.08.1.2.2009 TOP PAN 120mm
3.08.1.2.2011 TOP PAN 145mm
3.08.2.3.2031 BREEZE SHIELD WITH LID
3.08.2.3.2033 IN USE COVER
7.00.1.0.0046 SECURITY LOCK AND CABLE
EN
© Adam Equipment 2016 16 308669539revB6-Mar17
7.0 SPECIFICATIONS
Model# CQT‐202 CQT‐251 CQT‐601 CQT‐1501 CQT‐2601 CQT‐2000 CQT‐5000
MaximumCapacity 200g 250g 600g 1500g 2600g 2000g 5000g
Readability 0.01g 0.1g 0.1g 0.1g 0.1g 1g 1g
Resolution 1:20000 1:2500 1:6000 1:15000 1:26000 1:2000 1:5000
Repeatability(Std
Dev)
0.02g 0.1g 0.1g 0.2g 0.2g 1g 1g
Linearity± 0.02g 0.1g 0.1g 0.2g 0.2g 1g 1g
UnitsofMeasure kg/g/lb/oz/ct/dr/GN/N/tl.t
StabilisationTime 3seconds 2seconds 3seconds 2seconds
Operating
Temperature
0ºCto40ºC
32ºFto104ºF
PowerSupply 12VDCadapter800mASouthAfrica,500mArestofworld),or6xAAbatteries
Calibration Pushbuttoncalibrationusingexternalmass
CalibrationMass 200g 250g 600g 1500g 2000g 2000g 5000g
Display 6digitLCD,18mmdigits,withbacklight
Draftshield
(diameterxh)
132mmøx82mm
(5.2”øx3.2”)
N/A
BalanceHousing ABSPlastic
PanSize 120mmø(4.7”ø) 145mmø(5.7”ø)
OverallDimensions
(wxdxh)
173x255x86mm(6.8”x10”x3.4”)
Withoutdraftshield
NetWeight 820g(1.8lb)
EN
© Adam Equipment 2016 17 308669539revB6-Mar17
8.0 WARRANTY
STATEMENT
Adam Equipment offers Limited Warranty (Parts and Labour) for any components that fail due to defects in
materials or workmanship. Warranty starts from the date of delivery.
During the warranty period, should any repairs be necessary, the purchaser must inform its supplier or Adam
Equipment Company. The company or its authorised Technician reserves the right to repair or replace the
components at any of its workshops at no additional cost, depending on the severity of the problems. However,
any freight involved in sending the faulty units or parts to the Service Centre should be borne by the purchaser.
The warranty will cease to operate if the equipment is not returned in the original packaging and with correct
documentation for a claim to be processed. All claims are at the sole discretion of Adam Equipment.
This warranty does not cover equipment where defects or poor performance is due to misuse, accidental damage,
exposure to radioactive or corrosive materials, negligence, faulty installation, unauthorised modifications or
attempted repair, or failure to observe the requirements and recommendations as given in this User Manual.
This product may include a rechargeable battery that is designed to be removed and replaced by the user. Adam
Equipment warrants that it will provide a replacement battery if the battery manifests a defect in materials or
workmanship during the initial period of use of the product in which the battery is installed.
As with all batteries, the maximum capacity of any battery included in the product will decrease with time or use,
and battery cycle life will vary depending on product model, configuration, features, use, and power management
settings. A decrease in maximum battery capacity or battery cycle life is not a defect in materials or workmanship,
and is not covered by this Limited Warranty.
Repairs carried out under the warranty do not extend the warranty period. Components removed during warranty
repairs become company property.
The statutory rights of the purchaser are not affected by this warranty. The terms of this warranty is governed by
the UK law. For complete details on Warranty Information, see the terms and conditions of sale available on our
web-site.
FR
© Adam Equipment 2016 36 308669539revB6-Mar17
9.0 CERTIFICATDECALIBRAGE
DE
© Adam Equipment 2016 57 308669539revB6-Mar17
9.0 KALIBRIERZERTIFIKAT
ES
© Adam Equipment 2016 59 308669539revB6-Mar17
Adam Equipment
Serie Core
(P.N. 9539, Revision B5, Marzo 2017)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99

Adam Equipment CORE Serie User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI