Convair PRAC CP10S CM10W Owner's manual

Category
Mobile air conditioners
Type
Owner's manual
(English)(CP10,CM10)
CP10S CM10W
®
OWNER’SMANUAL
PortableRefrigerated AirConditioner
i
CM10W/CP10SPortableRefrigerated AirConditioner
Pleasereadtheseinstructionspriortousingtheapplianceand
savethemforfuturereference.
Wasteelectricalproductsmustnotbedisposedofwithhousehold
waste. Thisproductshouldbetakentoyourlocalrecyclingcentrefor
safetreatment.
CONTENTS
Introduction......................................1
Safety ..............................................2
Componentlocation.........................3
Installingtheexhausthose ..............4
Controlpanel ...................................5
Remotecontrol ................................6
Operation......................................7-8
Maintenance ....................................9
Troubleshooting .............................10
Specifications.................................11
Warranty ........................................12
SEELEY INTERNATIONAL – OWNER’SMANUAL
1
THANK YOU forchoosingaConvair
AirConditioner.Thisappliancehas
beencarefullyengineeredtobringyou
trouble-freepersonalairconditioning.
Pleasereadthismanualcarefullyso
thatyoutakefulladvantageofthe
manybenefitsyourConvairprovides.
Thisapplianceisnotintendedforuseby
persons(includingchildren)withreduced
physical,sensoryormentalcapabilities,
orlackofexperienceandknowledge,
unlesstheyhavebeengivensupervision
orinstructioninusingtheappliancebya
personresponsiblefortheirsafety.
Childrenshouldbesupervisedtoensure
thattheydonotplaywiththeappliance.
Donotplaceanythingthroughthe
ventilatingslots.
YourConvaircoolerisaportableair
conditioningunitthatsuppliesrefrigerated
airtoapersonalareawithinaroom.Itis
notintendedtofunctionasahouseor
roomairconditioner.
Besuretheappliancehasbeensecurely
andcorrectlyinstalledaccordingtothe
installationinstructionscontainedwithin
thismanual.
PersonalCooling
EnergySavingTips
Warranty
D
D
D
D
D
Donotlocatetheairconditionerwhere
furnitureorotherobjectscanobstructthe
airflow.
Keepcurtainsandblindsclosedduring
thehottestpartoftheday.
Keepthefiltersclean.
Settheairconditionertomaximum
coolingandhighfanspeedinitially,then
adjusttoacomfortablesetting.
Donotwaituntiltheroomisexcessively
hotbeforeusingtheairconditioner.
Convairairconditionersarewarranted
againstfaultymanufacturefor2yearsafter
purchase.Pleaserefertopage12formore
detailsonwarranty.
SEELEY INTERNATIONAL – OWNER’SMANUAL
1
INTRODUCTION
i
CM10W/CP10SPortableRefrigerated AirConditioner
Pleasereadtheseinstructionspriortousingtheapplianceand
savethemforfuturereference.
Wasteelectricalproductsmustnotbedisposedofwithhousehold
waste. Thisproductshouldbetakentoyourlocalrecyclingcentrefor
safetreatment.
CONTENTS
Introduction......................................1
Safety ..............................................2
Componentlocation.........................3
Installingtheexhausthose ..............4
Controlpanel ...................................5
Remotecontrol ................................6
Operation......................................7-8
Maintenance ....................................9
Troubleshooting .............................10
Specifications.................................11
Warranty ........................................12
SEELEY INTERNATIONAL – OWNER’SMANUAL
1
THANK YOU forchoosingaConvair
AirConditioner.Thisappliancehas
beencarefullyengineeredtobringyou
trouble-freepersonalairconditioning.
Pleasereadthismanualcarefullyso
thatyoutakefulladvantageofthe
manybenefitsyourConvairprovides.
Thisapplianceisnotintendedforuseby
persons(includingchildren)withreduced
physical,sensoryormentalcapabilities,
orlackofexperienceandknowledge,
unlesstheyhavebeengivensupervision
orinstructioninusingtheappliancebya
personresponsiblefortheirsafety.
Childrenshouldbesupervisedtoensure
thattheydonotplaywiththeappliance.
Donotplaceanythingthroughthe
ventilatingslots.
YourConvaircoolerisaportableair
conditioningunitthatsuppliesrefrigerated
airtoapersonalareawithinaroom.Itis
notintendedtofunctionasahouseor
roomairconditioner.
Besuretheappliancehasbeensecurely
andcorrectlyinstalledaccordingtothe
installationinstructionscontainedwithin
thismanual.
PersonalCooling
EnergySavingTips
Warranty
D
D
D
D
D
Donotlocatetheairconditionerwhere
furnitureorotherobjectscanobstructthe
airflow.
Keepcurtainsandblindsclosedduring
thehottestpartoftheday.
Keepthefiltersclean.
Settheairconditionertomaximum
coolingandhighfanspeedinitially,then
adjusttoacomfortablesetting.
Donotwaituntiltheroomisexcessively
hotbeforeusingtheairconditioner.
Convairairconditionersarewarranted
againstfaultymanufacturefor2yearsafter
purchase.Pleaserefertopage12formore
detailsonwarranty.
SEELEY INTERNATIONAL – OWNER’SMANUAL
1
INTRODUCTION
2
SAFETY
Forindooruseonly.
Ensuretheappliancehasbeeninstalledin
accordancewithnationalwiringregulations.
Transporttheairconditionerinan
uprightpositiononly,orleaveitinan
uprightpositionforatleast2hours
beforeuse(Fig1).
Useonlyintheuprightpositiononaflat
levelsurfaceandatleast50cmfromany
objects.
Donotplaceobjectsontheairconditioner,
orthroughtheventilatingslotsorrestrictthe
airinlets&outlets(Fig2).
Closelysuperviseanychildrenandpets
whentheairconditionerisinuse.
ElectricalSafety
Donotstoreoroperatetheappliancenear
anyflammablesubstances.
Duringoperation,waterwillcollectinthe
bottomtankoftheairconditioner.Be
carefulwhenmovingtheunittoprevent
waterfromspilling.
ElectricalSafety(cont)
Caution!beforeconnectingthe
electricalpowercordtoapoweroutlet,
checkthattheairconditionervoltage
isthesameasyourpowersupply (refer
totheratinglabellocatedonthesideof
theunit-referFig4).Ensurethepower
supplyiscorrectlyearthedandrated.
Plugtheairconditionerdirectlyintoa
properlyinstalledpoweroutlet.Neveruse
anextensioncord,doubleadaptorormulti
poweroutletboardtorunthisair
conditioner.
Donotpulltheunitalongbythepower
cordorplacethepowercordneara
sourceofheat. Alwaysunrollthepower
cordcompletelybeforeuse.
Switchoffandunplugwhennotinuse.
Donotuseinhumidenvironmentssuch
asbathrooms,laundriesorothersteamy
orwetareas.
Donottouchoroperatetheair
conditionerwithwetordamphandsor
whenstandingbarefoot.
Ifthepowersupplycordisdamagedit
mustbereplacedbythemanufacturer,a
serviceagentorsimilarlyqualified
personsinordertoavoidahazard.
2
1
3SEELEY INTERNATIONAL OWNER’SMANUAL
4
3
Remote
Control
AirOutlet
Handle
VaneLever
DisplayPanel
ControlPanel
AirFilter
AirFilter
Drain
AirIntake
Power
Cord
Exhaust Air
Outlet
ExhaustHose
Window Attachment
ExhaustFitting
(windowend)
Rating
Label
CM10W/CP10SPortableRefrigerated AirConditioner
COMPONENTLOCATION
2
SAFETY
Forindooruseonly.
Ensuretheappliancehasbeeninstalledin
accordancewithnationalwiringregulations.
Transporttheairconditionerinan
uprightpositiononly,orleaveitinan
uprightpositionforatleast2hours
beforeuse(Fig1).
Useonlyintheuprightpositiononaflat
levelsurfaceandatleast50cmfromany
objects.
Donotplaceobjectsontheairconditioner,
orthroughtheventilatingslotsorrestrictthe
airinlets&outlets(Fig2).
Closelysuperviseanychildrenandpets
whentheairconditionerisinuse.
ElectricalSafety
Donotstoreoroperatetheappliancenear
anyflammablesubstances.
Duringoperation,waterwillcollectinthe
bottomtankoftheairconditioner.Be
carefulwhenmovingtheunittoprevent
waterfromspilling.
ElectricalSafety(cont)
Caution!beforeconnectingthe
electricalpowercordtoapoweroutlet,
checkthattheairconditionervoltage
isthesameasyourpowersupply (refer
totheratinglabellocatedonthesideof
theunit-referFig4).Ensurethepower
supplyiscorrectlyearthedandrated.
Plugtheairconditionerdirectlyintoa
properlyinstalledpoweroutlet.Neveruse
anextensioncord,doubleadaptorormulti
poweroutletboardtorunthisair
conditioner.
Donotpulltheunitalongbythepower
cordorplacethepowercordneara
sourceofheat. Alwaysunrollthepower
cordcompletelybeforeuse.
Switchoffandunplugwhennotinuse.
Donotuseinhumidenvironmentssuch
asbathrooms,laundriesorothersteamy
orwetareas.
Donottouchoroperatetheair
conditionerwithwetordamphandsor
whenstandingbarefoot.
Ifthepowersupplycordisdamagedit
mustbereplacedbythemanufacturer,a
serviceagentorsimilarlyqualified
personsinordertoavoidahazard.
2
1
3SEELEY INTERNATIONAL OWNER’SMANUAL
4
3
Remote
Control
AirOutlet
Handle
VaneLever
DisplayPanel
ControlPanel
AirFilter
AirFilter
Drain
AirIntake
Power
Cord
Exhaust Air
Outlet
ExhaustHose
Window Attachment
ExhaustFitting
(windowend)
Rating
Label
CM10W/CP10SPortableRefrigerated AirConditioner
COMPONENTLOCATION
4
ASSEMBLINGTHEEXHAUSTHOSE
Step1:
Step2:
Step3:
Fittheexhausthosetotherear
paneloutletbyscrewingthehoseina
counter-clockwisedirection
Snaptheoblongconnectorinto
positiononthewindowattachment.
Openthewindowandfitthe
adjustablewindowattachment.Extendthe
attachmentasrequiredandlockintoplace
withthelockingscrew.Ensuretheoutletis
notobscured. Thewindowattachmentcan
beinstalledhorizontallyorvertically,
dependingonthewindowtype.
Note!
Note!
Theminimumdistancerequired
fromtheoperatingairconditionerto
anyobstructingobjectsorwallsis
50cm(Fig6).
Keeptheexhausthoseasshortand
straightaspossibleandminimise
kinks.Thiswillmaximisethecooling
performance.
Dontuseextensionpiecesforthe
exhaustpipeasthiswillreducethe
coolingperformanceandpossibly
resultindamagetotheairconditioner.
Hotairandpossiblymistwillbe
emittedfromtheexhausthose.
Itiscriticaltothecoolers
performancethatthehotexhaustairis
completelyremovedfromthespace
beingcooled.
6
5
50cm
5SEELEY INTERNATIONAL OWNER’SMANUAL
FanSpeed
controlbutton
Presstocyclethefan
speedbetweenlow
andhigh
Sleep
button
Presstoenterthe
sleepmode
Toavoiddamagetothecontrolpanel,donotoperatewithsharpobjects.
NOTE!
7
CONTROL PANEL
Display panel
8
Presstocyclefrom
Cooling,Dehumidifying
andFanmodes.
Presstoenterthe
timersettingmode
andtime
Presstoturnthe
airconditioneron
andoff
Press toincrease,
todecreasethe
settemperature
r
s
PowerON/OFF
button
TimerSet
button
ModeSelect
button
Temperatureadjust
buttons
comp
CoolingMode
Indicator
Compressor
Active
Indicator
Water Tank
Full
Indicator
Dehumidifying
ModeIndicator
Timer
Indicator
Set Temperature
Display
FanSpeed
Indicator
SleepMode
Indicator
FanMode
Indicator
CM10W/CP10SPortableRefrigerated AirConditioner
4
ASSEMBLINGTHEEXHAUSTHOSE
Step1:
Step2:
Step3:
Fittheexhausthosetotherear
paneloutletbyscrewingthehoseina
counter-clockwisedirection
Snaptheoblongconnectorinto
positiononthewindowattachment.
Openthewindowandfitthe
adjustablewindowattachment.Extendthe
attachmentasrequiredandlockintoplace
withthelockingscrew.Ensuretheoutletis
notobscured. Thewindowattachmentcan
beinstalledhorizontallyorvertically,
dependingonthewindowtype.
Note!
Note!
Theminimumdistancerequired
fromtheoperatingairconditionerto
anyobstructingobjectsorwallsis
50cm(Fig6).
Keeptheexhausthoseasshortand
straightaspossibleandminimise
kinks.Thiswillmaximisethecooling
performance.
Dontuseextensionpiecesforthe
exhaustpipeasthiswillreducethe
coolingperformanceandpossibly
resultindamagetotheairconditioner.
Hotairandpossiblymistwillbe
emittedfromtheexhausthose.
Itiscriticaltothecoolers
performancethatthehotexhaustairis
completelyremovedfromthespace
beingcooled.
6
5
50cm
5SEELEY INTERNATIONAL OWNER’SMANUAL
FanSpeed
controlbutton
Presstocyclethefan
speedbetweenlow
andhigh
Sleep
button
Presstoenterthe
sleepmode
Toavoiddamagetothecontrolpanel,donotoperatewithsharpobjects.
NOTE!
7
CONTROL PANEL
Display panel
8
Presstocyclefrom
Cooling,Dehumidifying
andFanmodes.
Presstoenterthe
timersettingmode
andtime
Presstoturnthe
airconditioneron
andoff
Press toincrease,
todecreasethe
settemperature
r
s
PowerON/OFF
button
TimerSet
button
ModeSelect
button
Temperatureadjust
buttons
comp
CoolingMode
Indicator
Compressor
Active
Indicator
Water Tank
Full
Indicator
Dehumidifying
ModeIndicator
Timer
Indicator
Set Temperature
Display
FanSpeed
Indicator
SleepMode
Indicator
FanMode
Indicator
CM10W/CP10SPortableRefrigerated AirConditioner
Note!
Important!
AirDirectionVanes:
InCoolingmode,thefanwillcontinue
torunevenwhenthecompressorhas
cycledoff.
Theairconditioneris
fittedwith2setsofairdirectionvanesfor
horizontalandverticalairdirection.
Carefullymovethevanestothedesired
positionbyhand(Fig12).
Duringcoolingmode,waterwill
collectintheairconditioner’stank. This
waterisrecirculatedandsomewillbe
exhaustedoutwiththehotair,butwillslowly
fillupthetank. Thisoccursmorequicklyin
humidconditions.Ifthetankshouldfill,the
‘waterfull’ symbol willflashonthe
controldisplay,theunitwill ‘beep’ andthen
shutdown. Thecoolercannotberestarted
untilthewatertankisdrained.Refertothe
Maintenancesectionfordrainingthetank
shouldthisoccur.
Startingtheairconditioner
Step1: Ensurethecoolerispluggedin
andswitchedon.
Step2:
Step3:
Coolingmode
Dehumidifyingmode
Fanmode
Step4:
!
Step5:
PresstheON/OFFbutton
ontheremotecontrolorON/OFF
buttononthecontrolpaneltostarttheair
conditioner.
PresstheMODEbutton on
thecontrolpanelorremotecontrolto
selectthedesiredoperatingmode(Fig.7
&11):
-refrigerated
cooling
-for
extractingmoisturefromtheair
-Fanonlyoperation
(nocooling)
Press / onthecontrol
panelorontheremotecontroltoselect
thedesiredoperating ‘set’ temperature.
InCoolingmode,coolingwilloccurifthe
settemperatureislessthantheroom
temperature.
Donotsetthecoolingtemperature
toolow. Thiswillconsumemorepower.
24°Cistherecommendedset
temperature,withhighfanspeed.
Changingthesettemperaturewill
havenoeffectinDEHUMIDIFYING or
FANmodes.
PresstheFANSPEEDbutton
onthecontrolpanelorremotecontrol
toadjustthefanspeed.Eachpresswill
cyclethefanspeedbetweenlowand
high.
r s
Thesettemperaturerangeis16°C-31°C
Tip
Note!
6
Iftherearetwoofthesameair
conditionersinstalled,theycannotbe
controlledseparately.Whenyouoperate
eitherremote,itwillturnonbothair
conditionersiftheyarebothwithinsignal
range(6metres).
Don’tlettheremotecontroldroponto
hardsurfacesorbesubjectedtosudden
shocksinanyway. Thewarrantydoesnot
covermisuseoraccidentaldamage.
Don’tplacetheremotecontrolindirect
sunlight,ornearextremesoftemperature.
Thiswillaffectthecontrol’stemperature
reading.
Don’tallowtheremotecontroltogetwet.
Don’tplacenearstrongelectromagnetic
waves.
Don’tmixoldandnewbatteries!
Iftheremotecontrolwillnotbeusedfora
longtime,removethebatteriestoavoid
corrosion.
Careofyourremotecontrol
Preparationbeforeoperation
DuringOperation
Removethebatterycoverandinsertnew
batteries
.
Removethebatteriesandreplacewithnew
ones.Ifthisdoesnotsolvetheproblem
contactyour nearestservicecentrefor
advice.
(AAA),makingsurethe+and-are
matchingthecompartmentmarkings(Fig
10)
Iftheremotecontrolwillnotoperatetheair
conditioner,thebatteriesmayneedtobe
replaced.
Theairconditionermustbepluggedin
andswitchedonfortheremotecontrolto
operatetheairconditioner. Touse,pointat
thesignalreceivingwindowonthefront
panelandpresstheremotebutton. Theair
conditionerwill “beep” whenasignalhas
beenreceived. Ifthereisnobeep,pressthe
remotebuttonagain,ensuringitiswithin
range(6metres)oftheairconditioner.
Note!
!
NOTE:
WASTEBATTERIESSHOULD
BEDISPOSEDOF CORRECTLY
REMOTECONTROL
9
Signal
transmissionpoint
Temperature
adjustbuttons
Sleepmodebutton
Ioniserbutton
(notused)
Fanspeed
adjustbutton
Modebuttons
(Cool-Dehumidify-Fan)
Timeron/adjust
button
PowerON/OFF
button
Battery
compartment
Batterycover
10
7SEELEY INTERNATIONAL OWNER’SMANUAL
OPERATION
Step.2
Step.7
Step.3
Step.5
Step.4
Step.6
11
12
CM10W/CP10SPortableRefrigerated AirConditioner
Note!
Important!
AirDirectionVanes:
InCoolingmode,thefanwillcontinue
torunevenwhenthecompressorhas
cycledoff.
Theairconditioneris
fittedwith2setsofairdirectionvanesfor
horizontalandverticalairdirection.
Carefullymovethevanestothedesired
positionbyhand(Fig12).
Duringcoolingmode,waterwill
collectintheairconditioner’stank. This
waterisrecirculatedandsomewillbe
exhaustedoutwiththehotair,butwillslowly
fillupthetank. Thisoccursmorequicklyin
humidconditions.Ifthetankshouldfill,the
‘waterfull’ symbol willflashonthe
controldisplay,theunitwill ‘beep’ andthen
shutdown. Thecoolercannotberestarted
untilthewatertankisdrained.Refertothe
Maintenancesectionfordrainingthetank
shouldthisoccur.
Startingtheairconditioner
Step1: Ensurethecoolerispluggedin
andswitchedon.
Step2:
Step3:
Coolingmode
Dehumidifyingmode
Fanmode
Step4:
!
Step5:
PresstheON/OFFbutton
ontheremotecontrolorON/OFF
buttononthecontrolpaneltostarttheair
conditioner.
PresstheMODEbutton on
thecontrolpanelorremotecontrolto
selectthedesiredoperatingmode(Fig.7
&11):
-refrigerated
cooling
-for
extractingmoisturefromtheair
-Fanonlyoperation
(nocooling)
Press / onthecontrol
panelorontheremotecontroltoselect
thedesiredoperating ‘set’ temperature.
InCoolingmode,coolingwilloccurifthe
settemperatureislessthantheroom
temperature.
Donotsetthecoolingtemperature
toolow. Thiswillconsumemorepower.
24°Cistherecommendedset
temperature,withhighfanspeed.
Changingthesettemperaturewill
havenoeffectinDEHUMIDIFYING or
FANmodes.
PresstheFANSPEEDbutton
onthecontrolpanelorremotecontrol
toadjustthefanspeed.Eachpresswill
cyclethefanspeedbetweenlowand
high.
r s
Thesettemperaturerangeis16°C-31°C
Tip
Note!
6
Iftherearetwoofthesameair
conditionersinstalled,theycannotbe
controlledseparately.Whenyouoperate
eitherremote,itwillturnonbothair
conditionersiftheyarebothwithinsignal
range(6metres).
Don’tlettheremotecontroldroponto
hardsurfacesorbesubjectedtosudden
shocksinanyway. Thewarrantydoesnot
covermisuseoraccidentaldamage.
Don’tplacetheremotecontrolindirect
sunlight,ornearextremesoftemperature.
Thiswillaffectthecontrol’stemperature
reading.
Don’tallowtheremotecontroltogetwet.
Don’tplacenearstrongelectromagnetic
waves.
Don’tmixoldandnewbatteries!
Iftheremotecontrolwillnotbeusedfora
longtime,removethebatteriestoavoid
corrosion.
Careofyourremotecontrol
Preparationbeforeoperation
DuringOperation
Removethebatterycoverandinsertnew
batteries
.
Removethebatteriesandreplacewithnew
ones.Ifthisdoesnotsolvetheproblem
contactyour nearestservicecentrefor
advice.
(AAA),makingsurethe+and-are
matchingthecompartmentmarkings(Fig
10)
Iftheremotecontrolwillnotoperatetheair
conditioner,thebatteriesmayneedtobe
replaced.
Theairconditionermustbepluggedin
andswitchedonfortheremotecontrolto
operatetheairconditioner. Touse,pointat
thesignalreceivingwindowonthefront
panelandpresstheremotebutton. Theair
conditionerwill “beep” whenasignalhas
beenreceived. Ifthereisnobeep,pressthe
remotebuttonagain,ensuringitiswithin
range(6metres)oftheairconditioner.
Note!
!
NOTE:
WASTEBATTERIESSHOULD
BEDISPOSEDOF CORRECTLY
REMOTECONTROL
9
Signal
transmissionpoint
Temperature
adjustbuttons
Sleepmodebutton
Ioniserbutton
(notused)
Fanspeed
adjustbutton
Modebuttons
(Cool-Dehumidify-Fan)
Timeron/adjust
button
PowerON/OFF
button
Battery
compartment
Batterycover
10
7SEELEY INTERNATIONAL OWNER’SMANUAL
OPERATION
Step.2
Step.7
Step.3
Step.5
Step.4
Step.6
11
12
CM10W/CP10SPortableRefrigerated AirConditioner
8
OPERATION
AirConditionerFeatures
Step6:
TimerFunction
Step7:Settingthetimer
YourairconditionerhasaSLEEP
mode,activatedbypressingthebuttonon
thecontrolpanelorremotecontrol.SLEEP
modewillchangethefanspeedto lowand
increasethesettemperatureby1°Ceach
hourfor2hours.Nofurtherchangewill
occurafterthe2ndhour.
SleepModecanonlybeusedduring
Coolingmode.
Theairconditionerisfittedwithatimer
function. Thiscanbesetupto24hoursin
advance. Tousethisfunction,thecooler
mustbeplugged inandreadytooperate.
WiththeairconditionerON,pressthe
TIMERbuttonontheremotecontrolor
controlpanel. Thecontrolpaneldisplaywill
flashandshowthetimesetting.Pressthe
TIMERbuttontoincreasethetimein1hour
incrementsfrom1-24hrs. After5seconds
thedisplaywillreverttotheSET
temperature.
WhentheairconditionerisOFF(butstill
pluggedin),repeattheabovetosettheON
time. Theairconditionerwillstartupwith
thelastsettingsused.
Whentheairconditionerisworking,
onlythe TIMEROFFcanbeset.Whenthe
airconditionerisoff,onlythe TIMERON
canbeset.
Thetimerfunctioncannotbeusedfor
dehumidifyingmode.
Note!
Howtocancelthetimer
0Tocancelthetimer,setthetimeto using
thecontrolpanelorremotecontrol. The
TIMERindicatorwillstopglowing.
9SEELEY INTERNATIONAL OWNER’SMANUAL
Drainingthe AirConditioner
Todraintheairconditioner,placeitovera
drainpointbeforeunscrewingthecapand
removingthedrainplug,aswaterwillflow
outassoonastheplugisremoved.
Removetheplugatthebottomrearofthe
applianceandallowthetankto
completelydrain(Fig13B).
Note! Alwaysreplacethedrainplug
immediatelyafterdraining.
Alwaysdisconnecttheairconditionerfromtheelectricitymainsbeforecleaningor
draining.
Tomaximizetheefficiencyoftheairconditioner,cleanregularly.
Neveroperatetheairconditionerwithoutthefilters.
Cleaningthehousing
Cleaningthefilters
Note!
Useasoft,dampclothtowipethebodyclean.
Neveruseaggressivechemicals,spirits,detergents,chemicallytreatedcloths,orother
cleansingsolutions. Thesesubstancescouldpossiblydamagethecabinet
Useavacuumcleanerortapthefilterlightlytoremoveloosedustanddirtandthenrinse
underrunningwater(nohotterthan40°C).
Drythoroughlybeforereplacing.
Takecaretoreplacethefiltersbackintotheslotsinthecooler.
.
Removethefiltersasshown(Fig13A).
Endofseasonstorage:
Drainanywaterfromtheunit.
Operatetheunitinfanonlymodeforafewhours,tothoroughlydrytheinside.
Cleanorchangethefilters.
Replaceinthe
originalcartonorcoverforstorage.
Unplugandcarefullystorethepowercordandplugend.
MAINTENANCE
B
13
A
Removeallfilters(4total)
fromtheairconditioner
andcleanevery2weeks.
CM10W/CP10SPortableRefrigerated AirConditioner
8
OPERATION
AirConditionerFeatures
Step6:
TimerFunction
Step7:Settingthetimer
YourairconditionerhasaSLEEP
mode,activatedbypressingthebuttonon
thecontrolpanelorremotecontrol.SLEEP
modewillchangethefanspeedto lowand
increasethesettemperatureby1°Ceach
hourfor2hours.Nofurtherchangewill
occurafterthe2ndhour.
SleepModecanonlybeusedduring
Coolingmode.
Theairconditionerisfittedwithatimer
function. Thiscanbesetupto24hoursin
advance. Tousethisfunction,thecooler
mustbeplugged inandreadytooperate.
WiththeairconditionerON,pressthe
TIMERbuttonontheremotecontrolor
controlpanel. Thecontrolpaneldisplaywill
flashandshowthetimesetting.Pressthe
TIMERbuttontoincreasethetimein1hour
incrementsfrom1-24hrs. After5seconds
thedisplaywillreverttotheSET
temperature.
WhentheairconditionerisOFF(butstill
pluggedin),repeattheabovetosettheON
time. Theairconditionerwillstartupwith
thelastsettingsused.
Whentheairconditionerisworking,
onlythe TIMEROFFcanbeset.Whenthe
airconditionerisoff,onlythe TIMERON
canbeset.
Thetimerfunctioncannotbeusedfor
dehumidifyingmode.
Note!
Howtocancelthetimer
0Tocancelthetimer,setthetimeto using
thecontrolpanelorremotecontrol. The
TIMERindicatorwillstopglowing.
9SEELEY INTERNATIONAL OWNERSMANUAL
Drainingthe AirConditioner
Todraintheairconditioner,placeitovera
drainpointbeforeunscrewingthecapand
removingthedrainplug,aswaterwillflow
outassoonastheplugisremoved.
Removetheplugatthebottomrearofthe
applianceandallowthetankto
completelydrain(Fig13B).
Note! Alwaysreplacethedrainplug
immediatelyafterdraining.
Alwaysdisconnecttheairconditionerfromtheelectricitymainsbeforecleaningor
draining.
Tomaximizetheefficiencyoftheairconditioner,cleanregularly.
Neveroperatetheairconditionerwithoutthefilters.
Cleaningthehousing
Cleaningthefilters
Note!
Useasoft,dampclothtowipethebodyclean.
Neveruseaggressivechemicals,spirits,detergents,chemicallytreatedcloths,orother
cleansingsolutions. Thesesubstancescouldpossiblydamagethecabinet
Useavacuumcleanerortapthefilterlightlytoremoveloosedustanddirtandthenrinse
underrunningwater(nohotterthan40°C).
Drythoroughlybeforereplacing.
Takecaretoreplacethefiltersbackintotheslotsinthecooler.
.
Removethefiltersasshown(Fig13A).
Endofseasonstorage:
Drainanywaterfromtheunit.
Operatetheunitinfanonlymodeforafewhours,tothoroughlydrytheinside.
Cleanorchangethefilters.
Replaceinthe
originalcartonorcoverforstorage.
Unplugandcarefullystorethepowercordandplugend.
MAINTENANCE
B
13
A
Removeallfilters(4total)
fromtheairconditioner
andcleanevery2weeks.
CM10W/CP10SPortableRefrigerated AirConditioner
10
Nevertrytodismantletheairconditioneryourself.
Problem Check
Theairconditionerdoesnot
run.
Istheairconditionerpluggedin?
Isthereapowerfailure?
Isthe"WATERFULL"errorcodeflashing?
Drainthetankasshown(Fig13).
Theairconditionerhaslittle
effect(firstlyensurethatthe
roombeingcooledisnottoo
largeforthestatedcapacity
oftheairconditioner).
Istheredirectsunshine?Remembertoclose
curtainsorblinds.
Arewindowsordoorsopen?
Morepeopleintheroomwillgeneratemore
heat.
Istheresomethingintheroomproducing
excessiveheat?
Istheexhaustfittedcorrectlyorobstructed?
Allexhaustairneedstobecompletely
removedfromtheroom.
Theairconditionerisnotas
coolasitoncewas.
Arethefiltersdusty ordirty,restrictingthe
airflow?
Istheairinletoroutletblocked?
Istheroomtemperaturebelowtheset
temperature?
Theairconditioneristoo
noisy.
Istheairconditionerpositionedunevenly,so
astocreatevibration?
Isthefloorbeneaththeairconditioner
uneven?
Itispossiblethattheoverheatprotectionfor
thecompressorison.Waitforittoreset.
Note:whenchangingbetweendifferentmodes
(coolingtofanordehumidifyingmodeetc)the
compressorwillturnoff. A 3minutedelaywill
occurbeforethecompressorwillturnonagain.
Thecompressorwillnotrun.
Incaseofproblemsthatcannotbefixedbyusingtheaboveguide,orifservice
onyourairconditionerisrequired,pleasecontactyourdealerordesignated
serviceagent.
TROUBLESHOOTING
Istheroomtemperaturebelowtheset
temperature?
11SEELEY INTERNATIONAL OWNERSMANUAL
SPECIFICATIONS
Basedonmanufacturer'stestresultsusingthe AirEnthalpymethod
Asapolicyofcontinualproductimprovement,thismanual,itscontentsandspecificationsaresubjecttochangewithoutnotice.
WIRINGDIAGRAM
LEVEL
SWITCH
PIPE TEMP
SENSOR
ROOM TEMP
SENSOR
BROWN
YELLOW
DISPLAY
BOARD
WT
MCU
BROWN
RED
RED
WHITE
BLUE
BLACK
YELLOW
RED
BLUE
BLACK
BLUE
YELLOW
&GREEN
COMP
PUMP
PUMP
PUMP
S C
R
FAN
FAN
MOTOR
AC-L
PT RT
CONTROL BOARD
SEELEY INTERNATIONAL -CLIMATEMASTER
PORTABLE AIRCONDITIONER
£
320/360/730
Model(s)
Function
CoolingCapacity(Watts)
AirFlowVolume(m /hr)
3
NoiseLevel-SoundPressure(dB(A))
PowerSupply
InputPower(Watts)
Fuse Type
Refrigerant Type/Charge(kg)
WaterIngressProtectionRating
Weight(kg)
Dimensions(mm)
(width/depth/height)
CP10S,CM10W
PersonalCooling
2900(10,000Btu/hr)
400
220-240V~50Hz
1100
3.15A /250V
R410A /0.46
3.2
0.8
IP20
55
HighSidePressure-Maximum(Mpa)
LowSidePressure-Maximum(Mpa)
22
CM10W/CP10SPortableRefrigerated AirConditioner
10
Nevertrytodismantletheairconditioneryourself.
Problem Check
Theairconditionerdoesnot
run.
Istheairconditionerpluggedin?
Isthereapowerfailure?
Isthe"WATERFULL"errorcodeflashing?
Drainthetankasshown(Fig13).
Theairconditionerhaslittle
effect(firstlyensurethatthe
roombeingcooledisnottoo
largeforthestatedcapacity
oftheairconditioner).
Istheredirectsunshine?Remembertoclose
curtainsorblinds.
Arewindowsordoorsopen?
Morepeopleintheroomwillgeneratemore
heat.
Istheresomethingintheroomproducing
excessiveheat?
Istheexhaustfittedcorrectlyorobstructed?
Allexhaustairneedstobecompletely
removedfromtheroom.
Theairconditionerisnotas
coolasitoncewas.
Arethefiltersdusty ordirty,restrictingthe
airflow?
Istheairinletoroutletblocked?
Istheroomtemperaturebelowtheset
temperature?
Theairconditioneristoo
noisy.
Istheairconditionerpositionedunevenly,so
astocreatevibration?
Isthefloorbeneaththeairconditioner
uneven?
Itispossiblethattheoverheatprotectionfor
thecompressorison.Waitforittoreset.
Note:whenchangingbetweendifferentmodes
(coolingtofanordehumidifyingmodeetc)the
compressorwillturnoff. A 3minutedelaywill
occurbeforethecompressorwillturnonagain.
Thecompressorwillnotrun.
Incaseofproblemsthatcannotbefixedbyusingtheaboveguide,orifservice
onyourairconditionerisrequired,pleasecontactyourdealerordesignated
serviceagent.
TROUBLESHOOTING
Istheroomtemperaturebelowtheset
temperature?
11SEELEY INTERNATIONAL OWNERSMANUAL
SPECIFICATIONS
Basedonmanufacturer'stestresultsusingthe AirEnthalpymethod
Asapolicyofcontinualproductimprovement,thismanual,itscontentsandspecificationsaresubjecttochangewithoutnotice.
WIRINGDIAGRAM
LEVEL
SWITCH
PIPE TEMP
SENSOR
ROOM TEMP
SENSOR
BROWN
YELLOW
DISPLAY
BOARD
WT
MCU
BROWN
RED
RED
WHITE
BLUE
BLACK
YELLOW
RED
BLUE
BLACK
BLUE
YELLOW
&GREEN
COMP
PUMP
PUMP
PUMP
S C
R
FAN
FAN
MOTOR
AC-L
PT RT
CONTROL BOARD
SEELEY INTERNATIONAL -CLIMATEMASTER
PORTABLE AIRCONDITIONER
£
320/360/730
Model(s)
Function
CoolingCapacity(Watts)
AirFlowVolume(m /hr)
3
NoiseLevel-SoundPressure(dB(A))
PowerSupply
InputPower(Watts)
Fuse Type
Refrigerant Type/Charge(kg)
WaterIngressProtectionRating
Weight(kg)
Dimensions(mm)
(width/depth/height)
CP10S,CM10W
PersonalCooling
2900(10,000Btu/hr)
400
220-240V~50Hz
1100
3.15A /250V
R410A /0.46
3.2
0.8
IP20
55
HighSidePressure-Maximum(Mpa)
LowSidePressure-Maximum(Mpa)
22
CM10W/CP10SPortableRefrigerated AirConditioner
12
WARRANTY
WARRANTYcont.
In this warranty:
or us means Seeley International Pty Ltd ABN 23 054 687 035, and our contact details are set out
at the end of this warranty;
means you, the original end-user purchaser of the Goods;
means the authorised distributor or retailer of the Goods that sold you the Goods in Australia;
and
means the product, unit, appliance or equipment which was accompanied by this warranty and
purchased in Australia.
Our Goods come with guarantees that cannot be excluded under the Australian Consumer Law. You
are entitled to a replacement or refund for a major failure and for compensation for any other
reasonably foreseeable loss or damage. You are also entitled to have the Goods repaired or replaced
if the Goods fail to be of acceptable quality and the failure does not amount to a major failure.
In addition to any rights and remedies that You may have under the Australian Consumer Law or any
other law, subject to the terms of this warranty, We provide the following warranty:
1. If, during the first 24 months from the date of first retail purchase ( ), the Goods
upon examination prove defective by reason of improper workmanship or material, We will repair
at our nearest service centre or replace (at our option), the product or any part thereof without
charge. Should we deem in our absolute discretion to replace the Goods, we may substitute any
similar good even if it is not on our current price/equipment list. Further, Goods presented for repair
may be replaced by refurbished goods of the same type rather than being repaired. Refurbished
parts may be used to repair the Goods.
2. We are under no obligation to repair or replace the Goods under clause 1 if the Goods have not
been used only for personal, domestic or household purposes or have not been operated and
maintained in accordance with the instructions in the Owner's Manual. The addition of any third
party device or the removal or the alteration of any of our components will void this warranty. In
addition, the warranty granted under clause 1 does not apply to:
Consumable components such as filters,
Adjustments necessary due to misuse of the cooler,
Normal user maintenance,
Setting of controls,
Transit damage, or
Damage caused by user misuse, tampering, or failure to observe the care and special
provisions in the instructions.
3. The warranty granted under clause 1 is limited to repair or replacement only. As far as the law
permits, We will not be liable for any consequential loss suffered through, or resulting from, the non
operation, or ineffective operation of the Goods. The warranty granted under clause 1 does not
cover damage to the Goods or other loss resulting from acts of God.
4. We are not responsible in any way for any failure and/or inadequate performance of the Goods
which arises from or is connected to the use in the Goods of non-genuine spare parts. We strongly
recommend that only spare parts supplied or approved by us are used in the Goods.
We
You
Supplier
Goods
Warranty Period
·
·
·
·
·
·
5. No other person, firm or corporation is authorised by us to offer or give on our behalf any other or
greater warranty than that given under this warranty. The benefits conferred by this warranty are in
favour of You and any person deriving title to the Goods through or under such person and are
intended to be separate from and additional to all other rights and remedies that they may have in
law in respect of the Goods.
6.
If it is less than fifteen (15) days from the date of purchase of the Goods, in order to claim under the
warranty granted under clause 1 You must return the Goods to the Supplier at the place of
purchase together with the proof of purchase.
13
SEELEY INTERNATIONAL OWNERSMANUAL
7. If it is more than fifteen (15) days after the date of purchase, in order to claim under the warranty
granted under clause 1 You must:
(a) either:
(i) contact us within the Warranty Period on: 1300 650 644;
or
(ii) log a claim on our website www.seeleyinternational.com within the Warranty Period;
and
(b) return the Goods to your nearest service centre (or to us at the address below) by prepaid
freight within the Warranty Period, together with (i) the legible and unmodified proof of
purchase, which clearly indicates the name and address of the original retailer, the date and
place of purchase, the product name or other product serial number, and (ii) a copy of the
completed Warranty Information below. (If you choose to return the Goods to us, there is an
additional requirement - they will also need to be accompanied by a covering letter which
states your name and address and daytime telephone number, and the model and serial
number of the goods.)
8. This warranty does not cover the cost of claiming under the warranty, it is your responsibility to
cover all forwarding and return freight costs incurred in sending the Goods to and from your
nearest service centre or us.
9. This warranty is only valid and enforceable in Australia.
Our liability under this warranty is limited to the extent permitted by law. That is, to the extent that it is
fair and reasonable, if the Goods are not of a kind ordinarily acquired for personal, domestic or
household use or consumption, your remedies associated with any failure or defect of the Product will
be limited to:
(a) the replacement of the Goods or the supply of equivalent goods;
(b) the repair of the Goods;
(c) the payment of the cost of replacing the Goods or of acquiring equivalent goods;
(d) the payment of the cost of having the Goods repaired
and subject to the terms and conditions included in this warranty.
To ensure that service either pursuant to the above warranty or otherwise is readily available, we have
established in all States authorised service centres, which are available to deal with service
requirements.
For further information about your nearest service centre and other enquiries please call our Service
Centre on:
1300650644
Please retain your receipt as proof of purchase. Every request for warranty must be
accompanied by proof of purchase.
:
Complete the following for your records:
: ...................................................................
...................................................................
Serial Number:
Model
Date purchased
Product
Purchased from
Convair CLIMATE MASTER
:
: ....../....../......
1 1CP10S CM10W
Service Department
Seeley International Pty Ltd
112 O'Sullivan Beach Road, Lonsdale, South Australia 5160
Customer service centre in Australia: 1300 650 644
Website: www.seeleyinternational.com
CM10W/CP10SPortableRefrigerated AirConditioner
12
WARRANTY
WARRANTYcont.
In this warranty:
or us means Seeley International Pty Ltd ABN 23 054 687 035, and our contact details are set out
at the end of this warranty;
means you, the original end-user purchaser of the Goods;
means the authorised distributor or retailer of the Goods that sold you the Goods in Australia;
and
means the product, unit, appliance or equipment which was accompanied by this warranty and
purchased in Australia.
Our Goods come with guarantees that cannot be excluded under the Australian Consumer Law. You
are entitled to a replacement or refund for a major failure and for compensation for any other
reasonably foreseeable loss or damage. You are also entitled to have the Goods repaired or replaced
if the Goods fail to be of acceptable quality and the failure does not amount to a major failure.
In addition to any rights and remedies that You may have under the Australian Consumer Law or any
other law, subject to the terms of this warranty, We provide the following warranty:
1. If, during the first 24 months from the date of first retail purchase ( ), the Goods
upon examination prove defective by reason of improper workmanship or material, We will repair
at our nearest service centre or replace (at our option), the product or any part thereof without
charge. Should we deem in our absolute discretion to replace the Goods, we may substitute any
similar good even if it is not on our current price/equipment list. Further, Goods presented for repair
may be replaced by refurbished goods of the same type rather than being repaired. Refurbished
parts may be used to repair the Goods.
2. We are under no obligation to repair or replace the Goods under clause 1 if the Goods have not
been used only for personal, domestic or household purposes or have not been operated and
maintained in accordance with the instructions in the Owner's Manual. The addition of any third
party device or the removal or the alteration of any of our components will void this warranty. In
addition, the warranty granted under clause 1 does not apply to:
Consumable components such as filters,
Adjustments necessary due to misuse of the cooler,
Normal user maintenance,
Setting of controls,
Transit damage, or
Damage caused by user misuse, tampering, or failure to observe the care and special
provisions in the instructions.
3. The warranty granted under clause 1 is limited to repair or replacement only. As far as the law
permits, We will not be liable for any consequential loss suffered through, or resulting from, the non
operation, or ineffective operation of the Goods. The warranty granted under clause 1 does not
cover damage to the Goods or other loss resulting from acts of God.
4. We are not responsible in any way for any failure and/or inadequate performance of the Goods
which arises from or is connected to the use in the Goods of non-genuine spare parts. We strongly
recommend that only spare parts supplied or approved by us are used in the Goods.
We
You
Supplier
Goods
Warranty Period
·
·
·
·
·
·
5. No other person, firm or corporation is authorised by us to offer or give on our behalf any other or
greater warranty than that given under this warranty. The benefits conferred by this warranty are in
favour of You and any person deriving title to the Goods through or under such person and are
intended to be separate from and additional to all other rights and remedies that they may have in
law in respect of the Goods.
6.
If it is less than fifteen (15) days from the date of purchase of the Goods, in order to claim under the
warranty granted under clause 1 You must return the Goods to the Supplier at the place of
purchase together with the proof of purchase.
13
SEELEY INTERNATIONAL OWNERSMANUAL
7. If it is more than fifteen (15) days after the date of purchase, in order to claim under the warranty
granted under clause 1 You must:
(a) either:
(i) contact us within the Warranty Period on: 1300 650 644;
or
(ii) log a claim on our website www.seeleyinternational.com within the Warranty Period;
and
(b) return the Goods to your nearest service centre (or to us at the address below) by prepaid
freight within the Warranty Period, together with (i) the legible and unmodified proof of
purchase, which clearly indicates the name and address of the original retailer, the date and
place of purchase, the product name or other product serial number, and (ii) a copy of the
completed Warranty Information below. (If you choose to return the Goods to us, there is an
additional requirement - they will also need to be accompanied by a covering letter which
states your name and address and daytime telephone number, and the model and serial
number of the goods.)
8. This warranty does not cover the cost of claiming under the warranty, it is your responsibility to
cover all forwarding and return freight costs incurred in sending the Goods to and from your
nearest service centre or us.
9. This warranty is only valid and enforceable in Australia.
Our liability under this warranty is limited to the extent permitted by law. That is, to the extent that it is
fair and reasonable, if the Goods are not of a kind ordinarily acquired for personal, domestic or
household use or consumption, your remedies associated with any failure or defect of the Product will
be limited to:
(a) the replacement of the Goods or the supply of equivalent goods;
(b) the repair of the Goods;
(c) the payment of the cost of replacing the Goods or of acquiring equivalent goods;
(d) the payment of the cost of having the Goods repaired
and subject to the terms and conditions included in this warranty.
To ensure that service either pursuant to the above warranty or otherwise is readily available, we have
established in all States authorised service centres, which are available to deal with service
requirements.
For further information about your nearest service centre and other enquiries please call our Service
Centre on:
1300650644
Please retain your receipt as proof of purchase. Every request for warranty must be
accompanied by proof of purchase.
:
Complete the following for your records:
: ...................................................................
...................................................................
Serial Number:
Model
Date purchased
Product
Purchased from
Convair CLIMATE MASTER
:
: ....../....../......
1 1CP10S CM10W
Service Department
Seeley International Pty Ltd
112 O'Sullivan Beach Road, Lonsdale, South Australia 5160
Customer service centre in Australia: 1300 650 644
Website: www.seeleyinternational.com
CM10W/CP10SPortableRefrigerated AirConditioner
00240801-D
convair.net.au
AU1112
WarrantyService
Australia1-300-650-644
seeleyinternational.com
ItisthepolicyofSeeleyInternationaltointroducecontinual
productimprovement. Accordingly,specificationsare
subjecttochangewithoutnotice.Pleaseconsultwithyour
dealertoconfirmthespecificationsofthemodelselected.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Convair PRAC CP10S CM10W Owner's manual

Category
Mobile air conditioners
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI