M-system CLSP User manual

Type
User manual

M-system CLSP

The M-system CLSP is a clamp-on pulse sensor designed for indoor use in environments with temperatures ranging from 0 to 55°C (32 to 131°F) and relative humidity within 80% RH. It has a power input rating of 12V DC and an operational range of 12V ±10%, with a maximum current draw of 5mA.

The CLSP is designed to be mounted on a wall using the provided mounting holes. It features a terminal cover that can be removed to connect wires according to the provided connection diagram. The input cable is connected by squeezing the levers on both sides of the top section to detach the tabs and pulling out the top section. The input cable is then placed in the indicated position and the top section is put back and bound over the tabs/levers with a binding strap.

M-system CLSP

The M-system CLSP is a clamp-on pulse sensor designed for indoor use in environments with temperatures ranging from 0 to 55°C (32 to 131°F) and relative humidity within 80% RH. It has a power input rating of 12V DC and an operational range of 12V ±10%, with a maximum current draw of 5mA.

The CLSP is designed to be mounted on a wall using the provided mounting holes. It features a terminal cover that can be removed to connect wires according to the provided connection diagram. The input cable is connected by squeezing the levers on both sides of the top section to detach the tabs and pulling out the top section. The input cable is then placed in the indicated position and the top section is put back and bound over the tabs/levers with a binding strap.

BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
PACKAGE INCLUDES:
Clamp-on pulse sensor ........................................................(1)
MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
POWER INPUT RATING & OPERATIONAL RANGE
•Locate the power input rating marked on the product and
confirm its operational range as indicated below:
12V DC rating: 12V ±10%, max. 5mA
GENERAL PRECAUTIONS
•Before you remove the module or mount it, turn off the
power supply and input signal for safety.
ENVIRONMENT
•Indoor use.
•When heavy dust or metal particles are present in the air,
install the module inside proper housing with sufficient
ventilation.
•Do not install the module where it is subjected to continu-
ous vibration. Do not subject the unit to physical impact.
•Environmental temperature must be within 0 to 55°C (32
to 131°F) with relative humidity within 80% RH in order
to ensure adequate life span and operation.
WIRING
•Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
•Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
AND ....
•The module is designed to function as soon as power is
supplied, however, a warm up for 10 minutes is required
for satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Terminal Cover
(separable)
Specifications
*
*Binding strap here
*
Tab
BodyInput Cable
Lever
Top Section
INSTALLATION
MOUNTING THE MODULE
1) Remove the terminal cover and connect wires according
to the connection diagram. Be aware of the wire inser-
tion direction (See ‘Inserting Wires’).
2) Put the terminal cover back so that its keys meet the key
holes. Be aware of the cover direction.
R1
R0
12V
Terminal Cover
Key
Terminal Cover
Key Hole
Mounting Hole
3) Tighten screws using the mounting holes to fix the mod-
ule on a wall.
CONNECTING THE INPUT CABLE
1) Squeeze the levers on both sides to detach the tabs and
pull out the top section.
2) Place the input cable to the position indicated on the
above drawing.
3) Put back the top section and bind over the tabs/levers
with a binding strap.
CLAMP-ON PULSE SENSOR
MODEL
CLSP
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: inf[email protected].jp
EM-9237 Rev.3 P. 1 / 2
INSTRUCTION MANUAL
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
EXTERNAL DIMENSIONS unit: mm (inch)
49.1 (1.93)
33 (1.30)
39 (1.54)
34 (1.34)
28 (1.10)
22 (.87)
2–3.5 dia. MTG HOLE
14
(.55)
79 (3.11)
5 (.20) dia.
3–M3 SCREW
TERMINAL COVER
R1
R0
12V
CONNECTION DIAGRAM
12V
R0
CLSP
PULSE INPUT
R1
+
+
POWER SUPPLY
PULSE OUTPUT
WIRING INSTRUCTIONS
SOLDERLESS TERMINAL unit: mm (inch)
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable. Solder-
less terminals with insulation sleeve do not fit.
Applicable wire size: 0.3 – 0.75 mm
2
3.2 (.13) dia.
4 min.
(.16)
12 (.47) max.
6 max.
(.24)
3 (.12) max.
INSERTING WIRES
Insert the output and power supply wires from the direction
as shown below and tighten firmly (torque 0.5 N·m).
R1
R0
12V
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage across the terminal
12V – R0 with a multimeter.
3) Input: Check the input signal.
4) Output: Check the output signal.
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.
CLSP
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: inf[email protected].jp
EM-9237 Rev.3 P. 2 / 2
  • Page 1 1
  • Page 2 2

M-system CLSP User manual

Type
User manual

M-system CLSP

The M-system CLSP is a clamp-on pulse sensor designed for indoor use in environments with temperatures ranging from 0 to 55°C (32 to 131°F) and relative humidity within 80% RH. It has a power input rating of 12V DC and an operational range of 12V ±10%, with a maximum current draw of 5mA.

The CLSP is designed to be mounted on a wall using the provided mounting holes. It features a terminal cover that can be removed to connect wires according to the provided connection diagram. The input cable is connected by squeezing the levers on both sides of the top section to detach the tabs and pulling out the top section. The input cable is then placed in the indicated position and the top section is put back and bound over the tabs/levers with a binding strap.