ESAB AristoFeed 30/48 Troubleshooting instruction

  • Hello! I am an AI chatbot trained to assist you with the ESAB AristoFeed 30/48 Troubleshooting instruction. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Service Information
Esab Welding Equipment AB
Reg. no: SI030324 ------------ NA Reg. no.: M-03-008
This information is valid for: AristoFeed 30/48
Error Code 11 in unit 3!
We have noticed some cases, where this error message shows up.
_________________________________________________________________________________________
Symptoms: There might be two different symptoms.
1. After pressing the Gun-trigger, the feeding speed will be max. for app. 5
sec,
then the feeder stops and the error 11 in unit 3, shows up at the display,
or into the error log.
2. The feeding speed will go max, above a certain speed, for instance 7m/min.
_________________________________________________________________________________________
Reason: Defective pulse generator in the Drive-unit.
_________________________________________________________________________________________
Actions: Use a Frequency meter or an Oscilloscope, to check the pulse signal between:
M2 and M3, at the Main Board.
If the pulse is missing or disappears above a certain set speed,
replace the drive unit, according to the normal complaint routine.
_________________________________________________________________________________________
For more information: See the service manual.
_________________________________________________________________________________________
Pelle Johansson
ESAB Service, LaxÄ
1
/