Kit Contents
Supply Adaptor - Qty. 1
Return Adaptor - Qty. 1
Gasketing
Inspection
Check carefully for any shipping damage. This must be
reported to and claims made against the transportation
company immediately. Any missing parts should be
reported to your supplier at once and replaced with
authorized parts only.
Install Adaptor Kit
1. Remove the panels covering both the horizontal supply
and return openings on the unit.
2. Attach gasketing to the flanges on both adaptors.
3. Place one of the adaptors over the supply opening.
Align the adaptor so that the left side edge of the
adaptor flange is flush to the side of the mitred corner
post on the cabinet, and the bottom flange of the
adaptor is flush with the bottom of the cabinet. Secure
with sheet metal screws. See Figure 1.
Models: BAYSQRD001AA and BAYSQRD002AA
HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING
WARNING:
IMPORTANT - This document is customer property and is to remain with this unit. Please return to service information pack upon
completion of work.
18-HE79D1-1
4. For use with small I2 cabinet*****016-36A Models
- Place the other adaptor over the return opening of the
cabinet. Align the adaptor so that there is 1” between
the flanges of the adaptors and that the bottom flange
is flush with the bottom of the cabinet. Secure with
sheet metal screws. See Figure 2.
For use with medium I2 cabinet *****042-060A
Models - Follow instructions above but leave a 4- 1/2”
gap. See Figure 2.
5. Connect field supplied flex duct to the adaptors and
secure with field supplied clamps. See Figure 3 for
dimensional drawings for flexduct sizing.
DO NOT APPLY WITH THE DUCT SHROUD COVER KITS
Installer’s Guide
Page 2
18-HE79D1-1
Figure 1. Install Supply Adapter
Figure 2. Install and Align Return Adapter
A INSTALL NOTE
BAYSQRD001AA
1" AS ABOVE
BAYSQRD002AA
4 1/2" LONGER 20.92" SIDE TOP/BOTTOM
Installers Guide
Page 3
18-HE79D1-1
BAYSQRD001AA Dimensions
(For use on *****018-036A Units)
* Depth is 6”.
BAYSQRD002AA Dimensions
(For use on ****042-060A Units)
Note: Flexduct size is 16”
Note: Flexduct size is 18”
14.42
18.85
16.42
20.85
20.35
20.92
18.85
19.42
* Depth is 6”.
Figure 3. Dimensional Drawing
SIDE
SIDE
TOP/BOTTOM
TOP/BOTTOM
Installer’s Guide
Page 4
18-HE79D1-1
American -Standard has a policy of continuous product and product data
improvement. It reserves the right to change design and specification
without notice.
American Standard inc.
6200 Troup Highway
Tyler, TX 75707-9010
Technical Literature - Printed in U.S.A.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

American Standard BAYSQRD001AA Installer's Manual

Type
Installer's Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI