AKM 202/NB

Whirlpool AKM 202/NB, AKM 202/IX, AKM 202/TF, AKM 202/WH Program Chart

  • Hello! I am an AI chatbot trained to assist you with the Whirlpool AKM 202/NB Program Chart. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • How do I ignite a burner?
    What should I do if the burner does not ignite?
    What are the dimensions of the cooktop and worktop?
    What types of gas can be used with this cooktop?
    What are the injector markings and rated heat capacities for each type of gas?
    What is the total rated heat capacity of the cooktop?
    How much air is required for burning?
AKM 202 PRODUCT DESCRIPTION SHEET
FR
Operation of burners
electronic ignition
To light one of the burners:
Press the relative knob and turn it anti-
clockwise to the large flame and star
setting .
At the same time, keep the knob pressed
against the control panel until the burner
ignites.
Release the knob.
If the burner does not ignite, repeat the
operations described above.
Note:
Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
1. Removable panstand grids
2-3. Medium burners
4. Large burner
5. Small burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Small burner control knob
Symbols
Shaded circle Tap closed
Large Maximum opening/
flame delivery and electronic
and star ignition
Small Minimum opening or
flame reduced delivery
5019 319 60141
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
Type of gas
used
Type of
burner
Injector
marking
Rated
heat
capacity
Pcs-kW
Rated
consumption
Reduced
heat
capacity
Pcs-kW
Gas pressure
min. rat. max.
NATURAL GAS
(Methane) G 20
large
medium
small
128
94
76
3.00
1.65
1.00
286 l/h
157 l/h
95 l/h
0.60
0.35
0.30
17 20 25
NATURAL GAS
(Groningen) G 25
large
medium
small
128
94
76
2.78
1.53
0.93
308 l/h
170 l/h
103 l/h
0.60
0.35
0.30
20 25 30
LIQUID
PETROLEUM GAS
(Cylinder) G 30
large
medium
small
85
65
50
3.00
1.65
1.00
218 l/h
120 l/h
73 l/h
0.60
0.35
0.30
20 28-30 35
LIQUID
PETROLEUM GAS
(Cylinder) G 31
large
medium
small
85
65
50
3.00
1.65
1.00
214 l/h
118 l/h
71 l/h
0.60
0.35
0.30
25 37 45
Type of gas
used
Appliance
model
Total rated
heat capacity
Pcs-kW
Total rated
consumption
Air required
for burning
m
3
/h
G 20 20 mbar 4 gas 7.30 695 l/h 14.6
G 25 25 mbar 4 gas 6.77 751 l/h 13.5
G 30 28-30 mbar 4 gas 7.30 531 l/h 14.6
G 31 37 mbar 4 gas 7.30 521 l/h 14.6
/