American Power Conversion AIS 3000 User manual

Category
Uninterruptible power supplies (UPSs)
Type
User manual
AIS
®
3000
10-40kVA
400V
Site Preparation and
Installation Manual
AIS
®
3000 10-40kVA 400V
Site Preparation and Installation Manual
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
This manual contains important instructions that should be
followed during installation and maintenance of the UPS and batteries.
ww
w
.apc.com
w
ww
.apc.com
w
w
w
.a
p
c
.c
o
m
w
w
w
.a
p
c
.c
o
m
Contents
AIS® 3000 10-40kVA, 400V, Site Preparation and Installation Manual – 990-2258 i
Safety .....................................................................1
SAVE THESE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Symbols used in this guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Environmental symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
General safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Introduction ............................................................4
UPS Family Range and Components . . . . . . . . . . . . . . . . . . . . . 6
352mm Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
523mm Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
System sizes, part Nos., number of Battery Modules and
weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Part number coding: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Battery Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Front Panel overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Stabilizing Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
User interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Battery Securing Bracket and Floor Anchoring . . . . . . . . . . . . . 11
Conduit Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Extended Run Battery Enclosure (XR Enclosure) and Battery
Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Part Numbers for XR Enclosures . . . . . . . . . . . . . . . . . . . . . . . 13
Part Number for Battery Module . . . . . . . . . . . . . . . . . . . . . . . 13
Maintenance Bypass Panels with Power Distribution Capability 14
Site Preparation .....................................................15
Installation Space Requirements . . . . . . . . . . . . . . . . . . . . . . . 15
Clearance for 523mm Enclosures . . . . . . . . . . . . . . . . . . . . . . . 15
Clearance for stand-alone 352mm Enclosures . . . . . . . . . . . . . 16
ii AIS® 3000 10-40kVA, 400V, Site Preparation and Installation Manual – 990-2258
Floor Anchoring Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Drilling floor holes for floor anchoring . . . . . . . . . . . . . . . . . . . 17
Hole positions for floor anchors (stand-alone Enclosures) . . . . . 17
Operating Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Heat dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Audible noise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Recommended source connections . . . . . . . . . . . . . . . . . . . . . 20
Recommended current protection . . . . . . . . . . . . . . . . . . . . . . 21
Minimum setting of breakers for 10kVA UPS . . . . . . . . . . . . . . 22
Minimum setting of breakers for 15kVA UPS . . . . . . . . . . . . . . 22
Minimum setting of breakers for 20kVA UPS . . . . . . . . . . . . . . 23
Minimum setting of breakers for 30kVA UPS . . . . . . . . . . . . . . 23
Minimum setting of breakers for 40kVA UPS . . . . . . . . . . . . . . 24
Recommended phase-conductor sizes for a 30°C
temperature environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
EPO switch wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Basic Wiring Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Site Preparation Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Electrical Installation ............................................ 28
Total-Power-Off Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
System-Electrical Information . . . . . . . . . . . . . . . . . . . . . . . . . 32
Source connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Input/Output Wiring – Single Mains (default) . . . . . . . . . . . . . 35
Wiring procedure - single mains . . . . . . . . . . . . . . . . . . . . . . . 35
Input/Output Wiring – Dual Mains . . . . . . . . . . . . . . . . . . . . . 37
Wiring procedure - dual mains . . . . . . . . . . . . . . . . . . . . . . . . . 37
AIS® 3000 10-40kVA, 400V, Site Preparation and Installation Manual – 990-2258 iii
Communication Wiring to EPO and Optional Equipment . . . . 39
Pin connections J106 (XR Enclosure) and J108 (EPO) . . . . . . . 39
Pin connections J106 (UPS) to J200 (XR Enclosure - option) . . . 40
XR Enclosure, APC Maintenance Bypass Panel, and Generator
Control wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Pin connections J108 (for EPO wiring options) . . . . . . . . . . . . 41
General Charge Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Charge setting procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Leveling Feet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Setting the leveling feet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Floor Anchoring (option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Floor anchoring of stand-alone systems . . . . . . . . . . . . . . . . . . 44
Battery securing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Wiring Verification Procedure . . . . . . . . . . . . . . . . . . . . . . . . . 46
Installation Site Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
LIMITED FACTORY WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . 49
APC product covered . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Terms of warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Non-transferable warranty extends to first purchaser for use . . 49
Assignment of warranties . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Drawings, descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Warranty claims procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Exclusions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Smart-UPS® VT 10-30kVA, 208V, Site Preparation and Installation – 990-1598
AIS® 3000 10-40kVA, 400V, Site Preparation and Installation Manual – 990-2258 1
Safety
SAVE THESE INSTRUCTIONS
This guide contains important instructions that should be followed when handling the UPS, Battery
Enclosures, and Batteries.
Symbols used in this guide
WARNING!
Risk of electric shock.
CAUTION!
Read this information to avoid equipment damage.
Indicates important information.
Indicates that more information is available on this subject in a different section of this
manual.
Indicates that more information is available on the same subject in a different manual.
Two people to lift a component weighing between 18 - 32 kg.
Three people to lift a component weighing between 32 - 54 kg.
Use a pallet jack or a forklift for components over 54 kg.
Safety – SAVE THESE INSTRUCTIONS
2 AIS® 3000 10-40kVA, 400V, Site Preparation and Installation Manual – 990-2258
Environmental symbols
General safety
Temperature Ventilation
requirements
Humidity Dust/Fumes Altitude
WARNING!
All electrical power and control wiring must be installed by a qualified electrician and
comply with local and national codes.
WARNING!
When connected, the UPS contains energy from both AC and DC sources. If the UPS
has dual mains supply, be aware of the two AC supply sources. Risk of electric shock -
parts inside the UPS are energized from the battery supply even the AC power is
disconnected. Follow the Total-Power-Off procedure in this manual to completely de-
energize the system. Disconnect charging source prior to connecting or disconnecting
battery terminals.
WARNING!
Servicing of batteries should be performed or supervised by personnel knowledgeable
of batteries and the required precautions. Keep unauthorized personnel away from
batteries.
WARNING!
Batteries do not contain serviceable parts. Only APC authorized personnel may open
batteries.
WARNING!
Do not dispose of battery or batteries in a fire. The battery may explode. Do not open or
mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. It
may be toxic.
WARNING!
Risk of Energy Hazard, 96 V, 7.2 Ampere-hour battery. Before replacing batteries,
remove watches, rings, or other metal objects. High energy through conductive
materials could cause severe burns.
WARNING!
When handling batteries, wear rubber gloves and boots. Do not lay tools or metal
objects on top of batteries.
Safety – SAVE THESE INSTRUCTIONS
AIS® 3000 10-40kVA, 400V, Site Preparation and Installation Manual – 990-2258 3
WARNING!
When replacing a Battery Unit, replace with the same number of the: APC SYBT1
(always replace a whole Battery Module (4 Battery Units) at a time).
WARNING!
Only trained personnel familiar with the construction and operation of the equipment
and the electrical and mechanical hazards involved, may install and remove system
components.
CAUTION!
Wait until you are ready to power up the system before installing Battery Modules in the
UPS. Failure to do so can result in a deep discharge of the batteries and cause permanent
damage. The time from the battery installation time till the UPS is powered up should
not exceed 72 hours or 3 days.
For configurations including customer-supplied external batteries, refer to
manufacturers battery installation and maintenance instructions.
4 AIS® 3000 10-40kVA, 400V, Site Preparation and Installation Manual – 990-2258
Introduction
Welcome to the Site Preparation and Installation Manual for the AIS
®
3000. This manual contains
information on how to prepare your site for the installation of the UPS and optional APC equipment
(also available at www.apc.com) and instructions on how to carry out the electrical and mechanical
installation.
Separate manuals are available on:
Receiving and Unpacking - part # 990-1961
Operation - part # 990-2259
The user manuals are provided in the documentation storage area at the top right corner
on the UPS (behind the Front Panel).
10/100Base-T
Probe
AP9619 Network Management Card EM
!
Reset
Output
Pwr
Zone
10/100
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Documentation
storage
Introduction – SAVE THESE INSTRUCTIONS
AIS® 3000 10-40kVA, 400V, Site Preparation and Installation Manual – 990-2258 5
For more information on APC products and services, visit us at www.apc.com
Most illustrations show 523mm Enclosures but apply to both Enclosure sizes. Any
differences between the two Enclosure sizes will be addressed in the manual.
6 AIS® 3000 10-40kVA, 400V, Site Preparation and Installation Manual – 990-2258
UPS Family Range and Components
352mm Enclosures
523mm Enclosures
10/10
0
Ba
s
e-T
P
r
ob
e
AP9619 Network Management C
a
rd
E
M
!
Reset
O
u
tput
Pw
r
Zo
n
e
1
0
/10
0
M
od
e
l
:
Se
r
ia
l
:
BA
TTE
R
Y UN
IT
M
od
el:
Se
r
ia
l
:
BATTERY
UNIT
Mo
del:
Ser
i
al
:
BA
T
T
ERY UNIT
M
od
el:
S
e
r
i
al
:
B
A
T
T
ERY UN
I
T
Mo
del:
Ser
i
a
l:
BA
T
T
E
R
Y
UN
I
T
M
o
d
el:
S
e
r
i
a
l
:
B
ATTERY UNIT
M
od
el:
Se
r
i
al
:
BA
T
T
ERY UNIT
M
o
del
:
Seri
a
l:
BAT
T
E
R
Y
U
NIT
www.apc.com
www.apc.com
Front view Rear view Front view without cover
10-20kVA
www.apc.com
www.apc.com
10
/100
Bas
e-T
Probe
AP96
19
Net
w
ork Manage
m
ent Ca
rd E
M
!
R
es
e
t
Out
put
Pw
r
Zo
ne
1
0
/100
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
M
o
del:
S
er
ial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
S
er
ial:
BATTERY UNIT
10/100Base-T
P
r
ob
e
AP96
1
9 Net
w
or
k
Management Card EM
!
R
e
set
O
u
tput
Pwr
Zone
10/1
00
Mo
d
el
:
S
erial
:
BATTERY UNIT
Mode
l
:
Se
ri
al
:
BATTERY UNIT
Mode
l
:
Ser
i
al:
BATTERY UNIT
M
o
d
el:
S
e
ri
a
l:
BATTERY UNIT
M
o
d
e
l:
Serial:
BATTERY UNIT
Mod
e
l:
Serial
:
BATTERY UNIT
Mod
e
l
:
S
er
i
a
l
:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Mo
d
e
l:
Se
r
i
a
l:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
S
e
ri
al:
BATTERY UNIT
Model:
Seri
al
:
BATTERY UNIT
M
o
del:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Front view Rear view
Front view without cover
10-20kVA
Front view without cover
30-40kVA
Blind plates
cover
empty battery
bays
Introduction – UPS Family Range and Components
AIS® 3000 10-40kVA, 400V, Site Preparation and Installation Manual – 990-2258 7
System sizes, part Nos., number of Battery Modules and weights
Part number coding:
Height (identical for all Enclosure sizes) 1490mm
Depth (identical for all Enclosure sizes) 854mm
System Size/ Enclosure
width
Installed weight Installed weight
APC Part No. kg APC Part No. kg
10kVA 352mm ISVT10KH1B2S 308.7 ISVT10KH2B2S 404.7
10kVA 523mm ISVT10KH1B4S 345.4 ISVT10KH2B4S 441.4
10kVA 523mm ISVT10KH3B4S 537.4 ISVT10KH4B4S 633.4
15kVA 352mm ISVT15KH2B2S 404.7
15kVA 523mm ISVT15KH2B4S 441.4 ISVT15KH3B4 537.4
15kVA 523mm ISVT15KH4B4S 633.4
20kVA 352mm ISVT20KH2B2S 404.7
20kVA 523mm ISVT20KH2B4S 472.0 ISVT20KH3B4S 568.0
20kVA 523mm ISVT20KH4B4S 664.0
30kVA 523mm ISVT30KH3B4S 569.0 ISVT30KH4B4S 665.0
40kVA 523mm ISVT40KH4B4S 665.0
ISVT10KH1B2S
ISVT 10K H 1B 2* S
Product
kVA
Voltage
Max.
2 Batt.
Modules
With
start-up
service
1 Batt.
Module
*) 4 = max. 4 Battery Modules
Introduction – UPS Family Range and Components
8 AIS® 3000 10-40kVA, 400V, Site Preparation and Installation Manual – 990-2258
Battery Module
One Battery Module consists of 4 Battery Units (shipping in the UPS Enclosure).
Front Panel overview
Mod
e
l
:
S
e
rial:
BATTERY
UNIT
M
o
de
l
:
Seri
a
l:
BA
TTE
RY U
N
I
T
Mod
el
:
S
e
r
i
a
l
:
BATT
E
RY UN
I
T
M
o
de
l
:
Ser
i
a
l
:
BA
TTE
R
Y
U
NIT
4 x 24kg
Front Panel attachment procedure described in the Front Panel section.
w
w
w
.a
p
c
.c
o
m
w
w
w
.a
p
c
.c
o
m
w
w
w
.a
p
c
.
c
o
m
w
w
w
.
a
p
c
.
c
o
m
Front Panel
for 352mm
Enclosure
Rear view of
Front Panel
for 523mm
Enclosure
with filters
Rear view of
Front Panel
for 352mm
Enclosure
with filters
Front Panel
for 523mm
Enclosure
Filter seen
from front
and rear
Filter seen
from front
and rear
Introduction – UPS Family Range and Components
AIS® 3000 10-40kVA, 400V, Site Preparation and Installation Manual – 990-2258 9
Stabilizing Bracket
Always install the Stabilizing Brackets on the 352mm Enclosure (shipped with the UPS) to enhance
the stability of the Enclosure.
If the Enclosure needs to be moved after Stabilizing Brackets have been attached to the Enclosure,
the Stabilizing Brackets must be pushed up into their high position.
Loosen the two screws of both Stabilizing Brackets, and push the bracket up into the high
position.
When the Enclosure has reached its new position, push the Bracket into its “down” position
again, and tighten the screws.
WARNING!
For stability reasons, do not remove Stabilizing Brackets from 352mm Enclosures.
10/100Base-T
Probe
AP9
6
1
9
Ne
twor
k
M
a
n
a
gem
e
n
t
C
ard
E
M
!
Re
se
t
Ou
tpu
t
Pwr
Z
o
ne
10
/
1
0
0
Mo
del
:
Se
rial
:
BATTERY UNIT
M
od
el
:
Ser
i
al
:
BATTERY UNIT
M
od
e
l
:
Se
r
ia
l
:
BATTERY UNIT
M
o
d
el:
S
e
r
i
al
:
BA
TTERY UN
IT
Mo
del
:
S
e
r
i
al
:
BA
T
T
E
R
Y
U
N
IT
Mod
el
:
Serial
:
B
AT
T
E
RY
U
N
IT
M
odel
:
Se
r
i
a
l
:
BATT
ER
Y
UNI
T
M
od
el:
Se
r
i
al:
BATTE
R
Y
U
NI
T
M
o
de
l
:
Seri
al
:
BATTERY UNIT
Model:
S
eri
a
l:
BATTERY UNIT
Model:
Se
r
i
al:
BATTERY UNIT
Mod
e
l
:
Ser
i
a
l:
BATTERY UNIT
M
od
e
l
:
Serial:
BATTERY UNIT
M
ode
l
:
Se
ri
al
:
BATTERY UNIT
Model:
Se
ri
al:
BATTERY UNIT
Mo
de
l
:
S
e
ria
l
:
BATTERY UNIT
Model:
Se
ria
l
:
BATTERY UNIT
M
odel:
Seria
l
:
BATTERY UNIT
M
od
e
l
:
S
erial:
BATTERY UNIT
M
ode
l
:
Serial:
BATTERY UNIT
Stabilizing
Bracket
Introduction – UPS Family Range and Components
10 AIS® 3000 10-40kVA, 400V, Site Preparation and Installation Manual – 990-2258
User interface
Display: user-control interface used to configure the functionality, monitor the system, set alarm
thresholds, and to provide audible and visual alarms.
Network Management Card with Environmental Monitor (AP9619): used for remote system
control and monitoring, e-mail notifications etc. See separate manual for the AP9619.
Computer-interface port for the connection of computers with APC Powerchute
®
software.
Mechanical Bypass Lever: used to bypass the upstream mains power around the UPS to support
the load directly = internal mechanical bypass operation.
Service port (for APC maintenance personnel only).
Display port for the connection of display communication cable.
Documentation storage.
10/100Base-T
Probe
AP9619 Network Management Card EM
!
Reset
Output
Pwr
Zone
10/100
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Introduction – Options
AIS® 3000 10-40kVA, 400V, Site Preparation and Installation Manual – 990-2258 11
Options
Battery Securing Bracket and Floor Anchoring
In seismic areas , each Battery Module must be secured with a Battery Securing Bracket.
Conduit Box
Battery Securing Bracket
Battery Securing Bracket SUVTOPT003
Battery Securing Brackets are also applicable to XR Battery Enclosure.
Floor-anchoring bolts are not provided with the UPS. Purchase the floor anchors locally.
Model
:
Se
r
ial:
BATTERY UNIT
M
o
del:
S
er
i
al:
BATTERY UNIT
Mo
d
el:
S
e
r
ial:
BATTERY UNIT
Mod
e
l:
S
er
i
al
:
BATTERY UNIT
Mode
l
:
Serial
:
BATTERY UNIT
Model:
S
er
i
a
l
:
BATTERY UNIT
Mod
e
l:
Serial:
BATTERY UNIT
Mode
l:
S
eria
l
:
BATTERY UNIT
Model:
Seri
al:
BATTERY UNIT
Mode
l
:
Seri
al:
BATTERY UNIT
Mod
e
l:
Ser
ial:
BATTERY UNIT
Mode
l:
Ser
i
al
:
BATTERY UNIT
Reuse transport brackets
as Floor Anchoring
Brackets
Battery Securing Bracket
Conduit Box
Conduit Box for 352mm Enclosures SUVTOPT001
Conduit Box for 523mm Enclosures SUVTOPT002
Conduit Box is also applicable to XR Battery Enclosure.
523mm
88mm
523mm
88mm
12 AIS® 3000 10-40kVA, 400V, Site Preparation and Installation Manual – 990-2258
Extended Run Battery Enclosure (XR Enclosure) and Battery Module
XR Enclosure weights:
2 Battery Modules 410.8kg
6 Battery Modules (4 of the modules are shipped separately on a pallet) 794.8kg
Battery Module weight
4 units = 1 Battery Module 4x24kg
Model:
Se
rial:
BAT
TERY
UN
I
T
Model:
Se
r
i
a
l:
BAT
TERY UNIT
Mo
de
l:
Se
rial
:
BATTERY UNIT
Mode
l:
Serial:
B
A
TTERY UNIT
w
w
w.apc.
com
ww
w.apc.com
Model:
Se
r
ial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
M
o
d
e
l
:
Serial:
BATTERY UNIT
M
odel:
Ser
i
al:
BATTERY UNIT
M
od
el:
Serial:
BATTERY UNIT
Mo
d
e
l
:
S
eria
l
:
BATTERY UNIT
M
odel:
Serial:
BATTERY UNIT
Model:
Se
r
ial:
BATTERY UNIT
M
ode
l
:
Se
r
ial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Se
r
ial:
BATTERY UNIT
Mod
el
:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
M
ode
l
:
Seri
a
l:
BATTERY UNIT
Mod
e
l:
Serial
:
BATTERY UNIT
M
ode
l:
S
er
ial:
BATTERY UNIT
Model:
S
er
ial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Mode
l
:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Mod
el
:
Serial:
BATTERY UNIT
Mode
l
:
S
e
rial:
BATTERY UNIT
M
odel
:
Serial:
BATTERY UNIT
Mode
l
:
S
erial:
BATTERY UNIT
Mod
e
l:
S
er
i
al:
BATTERY UNIT
M
ode
l
:
Se
r
i
al:
BATTERY UNIT
Mode
l
:
S
eri
al
:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
M
od
el
:
S
er
ia
l:
BATTERY UNIT
Mod
e
l:
S
e
rial:
BATTERY UNIT
Model:
Serial
:
BATTERY UNIT
Mo
del
:
Serial:
BATTERY UNIT
Mod
el
:
S
er
ial:
BATTERY UNIT
Model:
S
eri
al:
BATTERY UNIT
Model:
S
e
rial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
M
ode
l
:
S
er
ial:
BATTERY UNIT
M
ode
l
:
Serial:
BATTERY UNIT
M
odel
:
Serial:
BATTERY UNIT
Model:
S
er
i
al
:
BATTERY UNIT
Mod
el
:
S
er
ial:
BATTERY UNIT
M
odel
:
Ser
ial
:
BATTERY UNIT
M
odel:
S
e
ria
l
:
BATTERY UNIT
Mo
del
:
S
er
ial:
BATTERY UNIT
Model:
S
er
i
a
l
:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Mod
el:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Serial:
BATTERY UNIT
Model:
Ser
i
al:
BATTERY UNIT
Mod
e
l:
Ser
ial
:
BATTERY UNIT
M
o
de
l:
Se
r
ial:
BATTERY UNIT
Battery Module
XR Enclosure with Front Panel
XR Enclosure with DC
Breaker, fuses and 2 Battery
Modules
XR Enclosure with DC
Breaker, fuses
and 6 Battery Modules
XR Enclosure with
DC fuses only
XR Enclosure with
DC fuses only
523mm
1490mm
854mm
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

American Power Conversion AIS 3000 User manual

Category
Uninterruptible power supplies (UPSs)
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI