  • Hello! I am an AI chatbot trained to assist you with the DKS No Touch Push Button User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Instructions for 1211-083 No Touch Lighted Exit Button
The 1211-083 is designed for indoor or outdoor use. Mount the button 40 to 48 inches
vertically above the floor and within 5-feet of the door (NFPA 101, Life Safety Code).
This is a “No Touch” button. It senses when an object (hand) is within approximately three
(3) inches of the button front and activates the relay to release the door.
The button can easily be mounted in a standard single-gang electrical box.
The button will illuminate with 12-Volt DC power. Button IS Polarity Sensitive. Be sure the
POSITIVE DC Power lead is connected to the RED wire, and the NEGATIVE DC Power lead
is connected to the BLACK wire.
No Touch
EXIT
Black
Red
Green
White
Yellow
+12 VDC
-12 VDC (GND)
NC (Normally Closed)
NO (Normally Open)
Common
P/N 1211-066 REV A 3/14
/