Samsung AX1AH9000WK User manual

  • Hello! I am an AI chatbot trained to assist you with the Samsung AX1AH9000WK User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
QUESTIONS OR COMMENTS?
COUNTRY CALL OR VISIT US ONLINE AT
SOUTH AFRICA 0860 SAMSUNG (726 7864)
www.samsung.com/support
BOTSWANA 8007260000
NAMIBIA 08 197 267864
ZAMBIA 0211 350370
MAURITIUS 800 2550
REUNION 0262 50 88 80
MOZAMBIQUE 847267864 / 827267864
NIGERIA 0800-726-7864
www.samsung.com/africa_en/support
GHANA
0800-10077
0302-200077
COTE D’IVOIRE 8000 0077
www.samsung.com/africa_fr/supportSENEGAL 800-00-0077
CAMEROON 7095-0077
KENYA 0800 545 545
www.samsung.com/support
UGANDA 0800 300 300
TANZANIA 0800 755 755 / 0685 889 900
RWANDA 9999
BURUNDI 200
DRC 499999
SUDAN 1969
ACR AF9000H-BIG NA_IB_04901A-02_EN.indd 36 2015-09-04 오전 10:36:33
This manual is made with 100% recycled paper.
AX1AH9000WK
Air Purifier
user manual
imagine the possibilities
Thank you for purchasing this Samsung product.
EN
DB68-04901A-02
ACR AF9000H-BIG NA_IB_04901A-02_EN.indd 37 2015-09-04 오전 10:36:33
2
Product features
TOTAL AIR CARE!! Running both purifying and sterilizing functions at the same time!!
Air purication with 3-step ltering and ion sterilizing dual clean system: The combination of 3-step ltering system, Dust
lter (for big dust)Deodorization lter (for harmful gas/odor) HEPA lter (for ne dust) and Virus doctor sterilization
that generates ion, will enhance quality of indoor air.
Extraordinary air purifying technology of Virus doctor: The Virus doctor independently developed by Samsung is the
technology that the Hydroperoxy radical (HOO
-
) generated by the combination of active hydrogen (H) and oxygen ion(O
2
-
)
captures harmful materials oating in the air and destroys the hydrogen bond of protein structure for sterilization function.
High ecient purifying system
Ecient dust collection:
The HEPA lter inside the air purier can lter even invisible ne dust.
Outstanding deodorizing function:
The high ecient activated carbon lter in the air purier can quickly get rid of odors such as food, cigarette, etc.
Virus doctor:
It generates active hydrogen and ion to eliminate oating germs, viruses, allergen, etc. in the indoor air.
High sensitive sensor:
When dust sensor and Gas(Odor) sensor in the air purier detect dust and Gas(Odor), the air purier automatically runs
suitable operation for the environment while displaying pollution level of indoor air.
Fast and clean air purication
Fast air purication:
The large capacity of air purier can swiftly purify large space by using the 2 HEPA lters (green).
Fine dust elimination
The high ecient HEPA lter (blue) which shows better performance than existing HEPA lter (green) can eliminate even
micro-ne dust.
ACR AF9000H-BIG NA_IB_04901A-02_EN.indd 2 2015-09-04 오전 10:36:21
3
Contents
PREPARATION
Safety precautions ..........................................................................................................4
Checking before using the product........................................................................................11
BASIC OPERATION
Name of each part ........................................................................................................14
Using the remote controller ...............................................................................................18
Basic operation ...........................................................................................................20
TIMER
Setting the On/O timer ..................................................................................................22
OPTIONS
Using the Virus doctor operation ..........................................................................................24
Using the Turbo operation.................................................................................................25
SETTINGS
Using the lighting function................................................................................................26
Using volume function ....................................................................................................26
Using the lter reset function..............................................................................................27
OTHERS
Cleaning and maintaining the product ....................................................................................28
Trouble shooting..........................................................................................................33
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
(Applicable in countries with separate collection systems)
This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g.
charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life. To
prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate these
items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government oce,
for details of where and how they can take these items for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This product
and its electronic accessories should not be mixed with other commercial wastes for disposal.
ACR AF9000H-BIG NA_IB_04901A-02_EN.indd 3 2015-09-04 오전 10:36:21
4
Safety precautions
These safety precautions are for owner’s safety and prevention of property
damage. Therefore, please read this manual thoroughly before using your air
purier.
WARNING
Hazards or unsafe practices that may result in severe
personal injury or death.
CAUTION
Hazards or unsafe practices that may result in minor
personal injury or property damage.
Follow directions. Unplug the appliance.
Do NOT attempt. Do NOT disassemble.
Make sure the machine is grounded to prevent electric shock.
FOR INSTALLATION
WARNING
Plug the power cord into a wall socket with the power specications
of the product or higher and use the socket for this appliance only.
Also, do not extend the power cord on your own.
Sharing a wall socket with other appliances using a multi outlet
power strip or extending the power cord may result in electric
shock or re.
Do not use an electric transformer. It may result in electric shock or
re.
If the voltage/frequency/rated current condition is dierent, it may
cause electric shock or re.
Do not install this appliance near a heater or a material vulnerable
to heat. Do not install this appliance in a humid, oily or dusty
location, in a location exposed to direct sunlight and water (rain
drops). Do not install this appliance in a location where gas may
leak.
Otherwise, electric shock or re may occur.
PREPARATION
ACR AF9000H-BIG NA_IB_04901A-02_EN.indd 4 2015-09-04 오전 10:36:21
PREPARATION
01
5
FOR INSTALLATION
CAUTION
The appliance should be installed in a place where the power cord
of the product can be easily pulled out.
Failure to do so may result in electric shock or re due to electric
leakage.
Install your appliance on a level and hard oor that can support its
weight.
Failure to do so may result in abnormal vibrations, noise, or product
malfunction.
When installing the appliance, allow enough space around the
appliance.
Space between the rear side of the appliance and the wall: At least
25 cm or more
Space between both sides of the appliance and the wall: At least 60
cm or more
If enough space for air intake is not provided, purifying capacity
may deteriorate.
If the appliance is too close to the wall, the wall paper may get
damaged.
Make sure obstacles such as a curtain do not block air inlet or outlet
of the appliance.
When installing the product, make sure that no heavy objects are
on the power cord (or cable).
Failure to do so may result in electric shock or re.
Conrm that the xing device has been installed with an
installation engineer.
If the xing device is not installed, the appliance may vibrate and
fall and this may result in injury.
ACR AF9000H-BIG NA_IB_04901A-02_EN.indd 5 2015-09-04 오전 10:36:21
6
Safety precautions
FOR POWER SUPPLY
WARNING
Unplug the product, and then remove foreign substances
(dust, moisture, etc.) from the power plug terminal or power plug
connection part with a dry cloth on a regular basis.
Otherwise, electric shock or re may occur.
When plugging in the appliance, the power plug should be
downward.
If the plug is positioned upward, the electric wires within the cable
may be damaged and this may result in electric shock or re.
When the power line is damaged, replace the damaged one with a
new one by a qualied technician.
Plug the power plug into the wall socket rmly. Do not use a
damaged power plug, damaged power cord or loose wall socket.
Otherwise, electric shock or re may occur.
When unplugging the product, do not pull the power cord. Grip the
power plug, and then pull the power plug.
Otherwise, electric shock or re may occur.
Do not pull or excessively bend the power cord. Do not twist or tie
the power cord. Do not hook the power cord over a metal object,
place a heavy object on the power cord, insert the power line
between objects, or push the power cord into the space behind the
appliance.
Otherwise, electric shock or re may occur.
ACR AF9000H-BIG NA_IB_04901A-02_EN.indd 6 2015-09-04 오전 10:36:21
PREPARATION
01
7
FOR POWER SUPPLY
CAUTION
When the air purier will not be used for a long period of time or
during a thunder or lightning storm, disconnect the power supply.
Failure to do so may result in electric shock or re.
It is dangerous when the power cable gets damaged, therefore
contact a service center or qualied experts for the repair.
Before cleaning or repairing the appliance, unplug the appliance.
FOR OPERATION
WARNING
If the appliance is ooded, turn o the appliance and contact a
service center.
If the appliance generates a strange noise, a burning smell or
smoke, disconnect the power supply immediately and contact a
service center.
Failure to do so may result in electric shock or re.
When gases (city gas, profane gas, etc.) leak, do not touch the
product or power cord. Immediately ventilate the area and contact
a service center or a qualied technician.
Do not use a ventilating fan.
If there is a spark, explosion or re may occur.
Do not unplug the appliance during operation.
When plugging the appliance in again, ame may occur and it may
result in electric shock or re.
When a repair is needed, contact the service center.
Failure to do so may result in a product malfunction, water leakage,
electric shock or re.
When installing the appliance, contact a service center.
A delivery service for the appliance is not provided. If you reinstall
the appliance in another location, additional installation fee will be
charged.
ACR AF9000H-BIG NA_IB_04901A-02_EN.indd 7 2015-09-04 오전 10:36:21
8
Safety precautions
FOR OPERATION
WARNING
Do not touch the power plug or auxiliary power switch with wet
hands.
Otherwise, electric shock may occur.
Do not apply a force to or pull the product using excessive force.
Otherwise, re, injury or product malfunction may occur.
After unpacking the air purier, keep all packaging materials out
of the reach of children.
If a child places a bag over its head, it may suocate.
Do not insert your ngers or a foreign substances into the air outlet
while product is operating.
Take special care that children do not injure themselves by inserting
their ngers into the product.
Do no place an object near the outdoor unit that makes it
possible for children to climb onto the machine.
The child could fall and injure themselves or the product may fall
over and injure the child.
Do not put other foreign materials such as metal into the
product.
Otherwise, electric shock or injury may occur.
If water has entered the power supply module, unplug the power
cable and dry the product completely before use.
Failure to do so may result in electric shock or re.
Do not place heavy objects on the product.
Otherwise, product malfunction or noise may occur.
Do not attempt to repair, disassemble, or modify the product
yourself.
Do not use a fuse (such as copper, steel wire, etc.) other than a
standard fuse.
Otherwise, electric shock, re, product malfunction or injury may
occur.
ACR AF9000H-BIG NA_IB_04901A-02_EN.indd 8 2015-09-04 오전 10:36:21
PREPARATION
01
9
If a foreign substance such as water has entered the electric part of the
product, disconnect the power supply and contact the service center.
Failure to do so may result in electric shock or re.
FOR OPERATION
CAUTION
Keep a distance of about 2 m from other electric appliances such as
a TV, video or audio device etc.
Failure to do so may result in reduced video quality or noise.
Allow enough space between the appliance and a wall.
Space between the rear side of the appliance and the wall: At least
25 cm or more
Space between the both sides of the appliance and the wall: At
least 60 cm or more
This appliance has a ow path which intakes and puries air at
the rear side of the appliance, so it is recommended to install the
appliance in the middle of the room. However, if it is installed near
the wall, make sure obstacles such as curtains do not block the air
inlet or outlet of the appliance.
Do not spray volatile material such as insecticide onto the product.
As well as being harmful to humans, this may also result in electric
shock, re or a product malfunction.
Do not tilt or turn the product upside down while the product is
connected to the wall outlet.
Otherwise, product malfunction or re may occur.
Do not put the product into water.
Otherwise, product malfunction may occur.
Do not place the product on the edge of a desk or table.
Do not stand on top of the product or place objects (such as
laundry, lighted candles, lighted cigarettes, dishes, chemicals, metal
objects, etc.) on the product.
Otherwise, electric shock, re, product malfunction or injury may occur.
Do not operate the product with wet hands.
Otherwise, electric shock may occur.
ACR AF9000H-BIG NA_IB_04901A-02_EN.indd 9 2015-09-04 오전 10:36:21
10
Safety precautions
FOR OPERATION
CAUTION
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised
to ensure that they do not play with the appliance.
For use in Europe: This appliance can be used by children aged from
8 years and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if they
have been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
FOR CLEANING
WARNING
Do not clean the product by spraying water directly onto it. Do not
use benzene, thinner, acetone or alcohol to clean the product.
Otherwise, discoloration, deformation, damage, electric shock or
re may occur.
Disconnect the power supply and stop the fan operation before
cleaning the product.
Otherwise, electric shock or re may occur.
ACR AF9000H-BIG NA_IB_04901A-02_EN.indd 10 2015-09-04 오전 10:36:21
PREPARATION
01
11
Checking before using the product
Checking before installing the product
Check that the location for installation meets the following conditions.
The oor should be level without a slope.
There should be no obstacles around the air inlet or outlet of the air purier.
The place should not be humid and there should be no inammable materials.
The space between the rear side of the product and a wall should be at least 25 cm or more.
The space between the both sides of the product and a wall should be at least 60 cm or more.
The rear side of the product should not come into contact with a curtain.
Before rst using the product or replacing the deodorization/HEPA lter (integrated type), remove the vinyl packing of
the lter.
Fix the air purier.
In any conditions and locations of installation, the product could be shaken or fall
by external force or children. Therefore, x the upper and rear side of the air purier
rmly by using the xing device.
Supply cords of parts of appliances for outdoor use shall not be lighter than
polychloroprene sheathed exible cord.
(Code designation IEC: 60245 IEC 57 / CENELEC:H05RN-F)
60 cm or more
25 cm or more
60 cm or more
Accessories
Remote controller
Remote controller
batteries
Fixing device M4 x 16 screw M4 x 25 screw
Integrated type lter User manual Holder lock
Cleaning cloth
(superne ber)
Power plug and wall socket
Use the 230 V wall socket for the power plug.
(When plugging in the product, the product will become operation standby status.)
When the product is not used for some time, unplug the product.
ACR AF9000H-BIG NA_IB_04901A-02_EN.indd 11 2015-09-04 오전 10:36:23
12
Checking before using the product
Information on the product
The product should not be used without the lter. When the lter smells bad, replace the lter with a new one.
The deodorization lter in the product is highly eective to remove not only domestic odor but also the formaldehyde,
VOCs, etc. which are the cause of sick house syndrome. Since the deodorizing function of the air purier becomes
eective as the air is circulated by the lter, ventilate the room at rst and then operate the deodorizing function if there
is strong odor. If you use the product in the suggested way, the performance of the air purier can be highly ecient.
If the air purier is used without a lter, air purifying function will not be carried out.
If the lter is dirty, purifying function works less eectively. If the exterior of the lter is dirty, the lter smells bad, or the
fan speed of the product observably decreases, the lter should be replaced.
When cooking food with a strong smell such as grilled sh, turn o the air purier.
If the air purier is used in a place where food with strong smell is made, the product life of the deodorization lter can
dramatically decrease. In the worst case, the smell from food pervades the deodorization lter and the lter generates
the food smell even after ventilation. Therefore, use the air purier to remove the remaining smell after carrying out
ventilation.
If the odor around the air purier pervades the HEPA or deodorization lter and generates the odor with the air purier
operation, the lters should be replaced.
When operating the air purier, close windows or doors.
If the air purier operates with the window or door opened, purifying function will work less eectively.
Carbon monoxide (CO) normally comes from outdoor area and it cannot be eliminated.
Main harmful gas that cannot be eliminated: Carbon monoxide (CO)
If the air purier is used in a closed area for long hours, concentration of carbon dioxide may increase. Therefore, carry
out ventilation regularly. If mild smell pervades the lter but it is used after ventilation several times, the smell of the lter
may decrease.
Using a lter
Before rst using the air purier, remove the vinyl packing of deodorization/HEPA lter (Integrated type).
- If an alarm rings or lter reset indicator blinks in the rst operation of the product, check the vinyl of the lter has been
removed.
If the air purier is used without a lter, air purifying function will not be carried out.
When the lter reset indicator ( ) is turned on, replace the old deodorization/HEPA lter (Integrated type) with new
ones. (The HEPA lter and deodorization lter eliminate particles of invisible ne dust and gas. Filter replacement period
can vary depending on the surrounding environment.)
If bad smell is generated, fan speed decreases, or replacement period passes, the deodorization/HEPA lter (Integrated
type) should be replaced.
If the dust lter is cleaned frequently, the eciency of the air purier increases.
For lter replacement procedure, refer to the 'Replacing the deodorization/HEPA lter' in the 'Cleaning and maintaining
the product' section.
Before replacing the lter, turn o the air purier.
ACR AF9000H-BIG NA_IB_04901A-02_EN.indd 12 2015-09-04 오전 10:36:23
PREPARATION
01
13
Checking for lter replacement period
Check the lter monitor hole or lter reset indicator to replace the lter.
Filter replacement period can be checked with the lter reset indicator.
When the lter reset indicator ( ) is turned on with alarm, replace the old deodorization/
HEPA lter (Integrated type) with new ones.
When you carry out the lter reset function after the lter is replaced, the alarm and the
( ) indicator will be turned o.
- When the lter reset indicator ( ) is displayed, the alarm rings every time you turn on
the air purier until you clear the lter reset indicator. (Refer to the 'Using the lter reset
function' p.27.)
The lter reset indicator is displayed according to the maximum operation hours of the
lter which is set regardless of surrounding environment. Therefore, the replacement
period can vary depending on the surrounding environment.
If a bad smell is generated or fan speed decreases, the lter should be replaced.
- Minor smell can be generated at the rst use of the air purier, but the smell will
disappear after the lter is used more than one day.
The pollution level of the lter can be checked.
You can check the pollution level of the HEPA lter (green) through the
lter monitor hole only when the lighting function is in operation.
Check the pollution level of the deodorization/HEPA lter (integrated type)
through the lter monitor hole on the side of the product.
- The pollution level of the lter can vary depending on the surrounding
environment.
- If the back of the lter monitor hole connected to the inside of the
lter is covered with dust, take out the lter and wipe the hole with a
superne ber cloth.
The HEPA lter (blue) at the lower part of the product cannot be checked
through the lter monitor hole. To check the pollution level, take out the
lower lter from the product.
Compare the pollution level of the lter with the colored label to decide
lter replacement.
- The colored labels are attached inside the lter frame.
(Upper part / 2 EA: green label, Lower part: blue label)
- As the lter is polluted, the color of the lter changes from green or blue
to gray.
Filter
monitor
hole
Rear hole
사용
교체필
Before usage
Change needed
使用前
需要更换
Green/
Blue
Gray
Product specication
Model name AX1AH9000WK
Product size (WxHxD) 360 mm x 1890 mm x 327 mm
Bottom space for the product
(CA certied)
151.2 m
2
Design and product specication may change for quality improvement without advance notice.
ACR AF9000H-BIG NA_IB_04901A-02_EN.indd 13 2015-09-04 오전 10:36:23
14
Name of each part
Air purier
Front side
Filter monitor hole
Virus doctor
Control panel
Remote controller holder
Fan blade
Moves with selected fan
direction
Front air outlet
Discharges clean air
Remote controller receiver
Support bracket
Display
CAUTION
If the support bracket is
excessively impacted, it may
become damaged.
BASIC OPERATION
ACR AF9000H-BIG NA_IB_04901A-02_EN.indd 14 2015-09-04 오전 10:36:24
15
BASIC OPERATION
02
Rear side
Deodorization lter
(black)
Deodorization/HEPA lter
(green)
Stepped-up deodorization
lter for speedy air
purication
Deodorization/HEPA lter
(blue)
Stepped-up HEPA lter for
ne dust elimination
Dust lter
Dust sensor
Detects dust
Gas(Odor) sensor
Detects Gas(Odor)
Air inlet
Intakes outdoor air
Air inlet
Intakes outdoor air
Side air outlet
Discharges clean air
NOTE
The deodorization lter (black) and HEPA lter (green/blue) are integrated.
Insert the integrated type deodorization/HEPA lter (green) into the 2 lter frames on the upper part of the air
purier.
Insert the integrated type deodorization/HEPA lter (blue) into the lter frame on the lower part of the air
purier.
CAUTION
Make sure the right lter is inserted into the lter frame by checking the
color of the lter to operate best air purifying function.
- The integrated type deodorization/HEPA lter (blue) should be inserted into
the lter frame on the lower part of the air purier.
ACR AF9000H-BIG NA_IB_04901A-02_EN.indd 15 2015-09-04 오전 10:36:24
16
Name of each part
Display
Filter reset indicator
Purity level indicator
Virus doctor
operation
indicator
Turbo
operation
indicator
Fan speed indicator
Timer indicator
Set time/Volume level
indicator
NOTE
Gas(Odor) and dust sensor operate to display purity level.
Purity level display
Red Orange Yellow Green Blue
(Polluted
Clean)
The purity level may change frequently or may not change for long hours depending on the surrounding
environment. Therefore, do not worry about product malfunction with this.
Buttons on the control panel
Power
Individual control button
Controls the front air outlet individually
Fan speed control button
Selects the fan speed
ACR AF9000H-BIG NA_IB_04901A-02_EN.indd 16 2015-09-04 오전 10:36:25
17
BASIC OPERATION
02
Operation with control panel
1. Press the Power button to operate the air purier.
All the air outlets open with melody sound and the air purier operates
with the mode last selected before it is turned o.
- At the rst operation, the air purier starts with Low fan speed.
Stop Press the Power button again.
2. Press the [ , ] button to select the fan speed.
Press the [] button to change the fan speed in order of:
L M H Auto Sleep L
Press the [] button to change the fan speed in order of:
L Sleep Auto H M L
3. Adjust fan height with the two individual control buttons.
The fan height can be adjusted by controlling the two front air outlets
individually.
Cancel
Press the Individual control button one more time.
NOTE
The two side air outlets cannot be adjusted individually.
When the two front air outlets are closed with the Individual
control button, the front air outlets stop operation and only the
side air outlets on the lower part of the product operate.
- Press the Individual control button again to open the front air
outlet.
The fan speed of each air outlet diers for pleasant air ow
control.
Press the Power button to turn o the side air outlet.
If the individual control is carried out by a remote controller, it is
not displayed on the remote controller.
Front air
outlet
Side air
outlet
ACR AF9000H-BIG NA_IB_04901A-02_EN.indd 17 2015-09-04 오전 10:36:25
18
Using the remote controller
Point the remote controller towards the remote controller receiver of the air purier.
When you properly press the button on the remote controller, you will hear a melody from the air purier and a transmit
indicator ( ) appears on the remote controller display.
Buttons on the remote controller
PM2.5/10
Checks the concentration of
PM2.5/10.
This model does not
support the function of
PM2.5/10 button.
Power
Turns on or o the air purier.
3D fan
Sets three-dimensional fan.
Wide fan
Sets wide fan.
Options
Selects operation.
Direction
Moves to select and set an option.
Adjust
Adjusts sound, lighting etc.
Fan speed
Selects the fan speed
Individual control button
Controls the front air outlet
individually.
SET
Selects or cancels an option.
Settings
Selects settings.
Timer
Sets timer option.
NOTE
In case you wish to cancel the options or settings that you have just set, select the set options and settings and
press the Options or Settings button on the remote controller again, then press the SET button.
Default setting for fan speed is Low. Press the Fan button to select the fan speed.
ACR AF9000H-BIG NA_IB_04901A-02_EN.indd 18 2015-09-04 오전 10:36:25
19
BASIC OPERATION
02
Remote controller display
On/O timer
Settings
Options
Fan speed
3D fan
Wide fan
Low Battery
Time for timer option
Remote controller
transmission
This model does not support the Wi function.
When the remote controller is turned o and turned on again, the last Timer, Options or Settings function which was
set before turning o the product is cancelled. However, the fan speed and Virus doctor operation remain.
Storing the remote controller
When you do not use the remote controller
for a long time, remove the batteries from the
remote controller and store it in the remote
controller holder.
Battery changing time
When the battery is exhausted, (
) indicator will be
displayed on the remote controller display. When the icon
appears, change the batteries. The remote controller requires
two 1.5 V AAA type batteries.
Inserting the batteries
1. Open the battery cover of the remote controller.
- Press the (
) part gently and lift it up in the arrow
direction.
2. Insert the batteries.
- Check and match the (+) and (-) signs accordingly.
3. Close the battery cover.
- Match the cover and bottom part of the remote
controller and press it until you hear click sound.
CAUTION
Make sure that water is not allowed to enter the remote controller.
NOTE
Use the remote controller that is only for operation of the air purier. When using the air conditioner remote
controller, the air purier may not operate properly or the display on the remote controller is not the same as
actual operation of the air purier.
There is a possibility that the air purier will not operate by the remote controller near strong light such as a
uorescent lamp or neon sign. In this case, use the remote controller in front of the remote controller receiver
of the air purier.
If other electrical products operate by the remote controller, call your nearest service center.
ACR AF9000H-BIG NA_IB_04901A-02_EN.indd 19 2015-09-04 오전 10:36:26
/