  • Hello! I am an AI chatbot trained to assist you with the Leviton GFSW1-T Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
APPLICATION NOTE
Combination GFCI/Switch (GFSW1)
GFSW1 COMBINATION GFCI/SWITCH APPLICATION NOTE
Leviton Mfg. Co., Inc.
201 North Service Road, Melville, NY 11747 Tech Line: 1-800-824-3005 Fax: 1-800-832-9538 www.leviton.com
© 2017 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.
INTRODUCTION
The Leviton combination GFCI/Switch can be used in a variety of
applications, with some requiring GFCI protection on the circuit connected
to the switch. The wiring diagrams shown within the instruction sheets
provided with the product are for applications in which GFCI protection IS
NOT REQUIRED for the circuit connected to the switch.
This application note contains the instructions for providing GFCI
protection to the circuit connected to the switch. (One example of an
application where the switched load requires GFCI protection is a Bathroom
Vanity light that contains an additional receptacle.)
For applications where GFCI protection of the circuit connected to the
switch IS REQUIRED, use the instructions below.
Connect the LINE cable wires to the LINE terminals:
- The white wire connects to the WHITE terminal (Silver).
- The black wire connects to the HOT terminal (Brass).
Connect the LOAD (Receptacle) cable wires to the GFCI LOAD
terminals: If applicable
- Remove the YELLOW sticker to reveal
the LOAD terminals.
- The white wire connects to the WHITE
terminal (Silver).
- The black wire connects to the HOT
terminal (Brass).
Connect switch leads to control LOAD
(WITH GFCI PROTECTION)
- One black switch lead connects to the
LOAD HOT terminal (Brass).
- The other black lead connects to the
hot side of the switched load.
- The neutral side of the switched
load must be connected to the LOAD
NEUTRAL terminal (Silver).
- The load must be grounded.
Connect the grounding wires (only if
there is a grounding wire):
- Connect a 6-inch bare copper (or
GREEN) 12 or 14 AWG wire to the
grounding terminal on the GFCI. If the
box has a grounding terminal, also
connect a similar wire to the grounding
terminal on the box. Connect the ends
of these wires to the LINE or LOAD
cable’s bare copper (or GREEN) wire
using a wire connector.
NOTE: If you are unsure about any
part of these instructions, consult a
qualified electrician.
G-10024/A17-dp
WHITE WIRE
FIL BLANC
HOT WIRE
FIL ACTIF
CHARGE
LOAD
LIGNE
LINE
Sw/Load Neutral (White)
Sw/Load Hot (Black)
Combination GFCI/Switch
with switched load GFCI protected
Line Hot (Black)
Receptacale Hot (Black)
Device Ground
Line Neutral (White)
Receptacle Neutral (White)
Line:
120VAC,
60Hz
Sw/Load
(Ground)
Receptacle (Ground)
GFCI Protected Fixture
Ground
Screw
Optional wiring
for downstream
receptacle
/