  • Hello! I am an AI chatbot trained to assist you with the Robertshaw Electromagnet Replacement Kit-TS Automatic Safety Valves for Model 1710 Body Types #9, 10, 11 and 12 only User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
1. Turn o all gas supply to equipment being serviced.
2. Disconnect thermocouple. Note locaon and direcon of thermocouple connecon.
3. Disconnect pilot gas tubing on models with a pilot inlet and/or outlet.
4. Remove the four Phillips head screws that aach magnet head to valve body.
Discard these screws.
5. Remove and discard the following:
A. Magnet head assembly
B. Diaphragm (note: Not all models have this thin metal piece.)
C. All gaskets
D. Main valve - Also discard valve spring on ow interrupon models.
6. Install new kit parts as follows:
A. Valve and spring assembly, with large end of spring against top of valve.
B. Diaphragm (note: Not all models have this thin metal piece.)
C. All gaskets
D. Main valve - Also discard valve spring on ow interrupon models.
7. Start four new Phillips head screws and ghten them evenly.
8. If model has pilot inlet and/or outlets, select correct ngs and connect pilot line(s).
9. Reconnect thermocouple.
10 Turn on gas supply and leak test.
11. Exnguish pilot ame and check for proper valve closing and gas shuto.
CAUTION
THIS DEVICE SHOULD BE INSTALLED BY A QUALIFIED SERVICE
TECHNICIAN WITH DUE REGARD FOR SAFETY, AS IMPROPER
INSTALLATION COULD RESULT IN A HAZARDOUS CONDITION.
INSTALLATION DATA
Electromagnet Replacement Kit-
TS Automatic Safety Valves
for Model 1710 Body Types
#9, 10, 11 and 12 only
191 E. North Avenue
Carol Stream Illinois 60188 USA
Customer Service Telephone 1.800.304.6563
Customer Service Facsimile 1.800.426.0804
Robertshaw®, Ranco®, Paragon® and
Uni-Line® are trademarks of Robertshaw
its subsidiaries and/or affiliated
companies. All other brands mentioned
may be the trademarks of their
respective owners.
For Technical Service
Telephone 1.800.445.8299
Facsimile 1.630.260.7294
www.uni-line.com
www.robertshaw.com
©2014 Robertshaw
07/14 – 1-050 Rev C
/