Tennant M-T5,M-T7 Instruction Bulletin

Type
Instruction Bulletin
CONTROL BOARD REPLACEMENT
BATTERY SELECT MODE
KIT NO. 9008406, 9006881, 9006882
Model: T5, T7
9010852 Rev. 01 (03- 2014) Tennant Company www.tennantco.com
Replacement control board must be programmed to accommodate battery type discharge rate. Failure to
properly program new control board may result in battery damage. Perform the Battery Select Mode
procedure as described below:
BATTERY SELECT MODE:
Setup Time: 2 minutes
TOOLS REQUIRED: None
Battery Select Mode Procedure
1. To enter the battery select mode, press and hold the solution flow increase button (+) while turning
key switch ON. Release the solution flow increase button when one of the LEDs on the battery
discharge indicator begins to blink.
2. Refer to the battery selection settings as shown below.
3. To select proper battery, press the solution flow decrease button (- ) to advance selection.
4. Turn key switch OFF to save setting.
Global/WET
(default)
Global/GEL
Red
Yellow
Green
Green
Solution Flow
Increase Button
Solution Flow
decrease Button
Battery
Discharge
Indicator
LED’s
Region/Battery Type
TNV/WET
Europe/WET
T5 Model T7 Model
Blinking LED
Solution Flow
Increase Button
Solution Flow
decrease Button
Region/Battery Type
Blinking LED
Battery
Discharge
Indicator
LED’s
Global/WET
(default)
Global/GEL
Red
Yellow
Green
Green
TNV/WET
Europe/WET
  • Page 1 1