10 ◆HPV-20 Installation Guide
Install the Ruby Software
Use software that supports the HPV-20 feature when installing or upgrading
the Ruby controller in a multiterminal system or standalone Ruby terminal in
a single-terminal system. Refer to the Gemstall Reference Manual.
Note: The HPV-20 enabled Ruby Card must be temporarily removed
when starting Genstall and replaced when the prompt, “Insert
HPV-20 Card now and press a key” is displayed.
If the Ruby terminal is connected to a back-office system using RubyLink for
communications, then RubyLink must be installed on two COM ports, which
requires a work-around. Do one of the following:
■Multiterminal system: Install RubyLink on a COM port on a
workstation and connect cable from the USB-to-serial converter to
the port assigned below in step 2.
■Standalone Ruby terminal: Contact the VeriFone Ruby Customer
Support Center for assistance in setting up a second COM port for
RubyLink on the single terminal.
Steps
Do the following when when selecting the site configuration in Gemstall:
1. Select ‘RubyLink’ as the “Back-Office” option in Gemstall.
Note: The back-office PC must run Gemcom32 to communicate
with the Ruby system when RubyLink is selected as the back-
office option in Gemstall.
2. Assign RubyLink to the COM port to which you will connect the
USB-to-serial, 9-pin converter. (In “Set Up the HPV-20 System
Hardware” procedures, see step 9.)
3. Select ‘HPV-20’.
4. Assign the HPV-20 primary COM port to COM 1 on the Ruby
controller and install all workstations as COM port “None”. Run the
RS-232 cable from the COM 1 port on the back of the Ruby terminal
to the red, null-modem adapter that is then connected to the serial port
of the e-PC. (In “Set Up the HPV-20 System Hardware” procedures,
see step 5.)