bora PL540E Operating instructions

Category
Cooker hoods
Type
Operating instructions
EN
PL540EUMEN-000
www.bora.com
Operating and installation instructions PL540E
Cooktop extractor
M8800359-000
Operating and installation instructions: Original Translation
Manufacturer
BORA Lüftungstechnik GmbH
Rosenheimer Str. 32
83064 Raubling
Germany
Contact
T +49 (0) 8035 / 907-240
F +49 (0) 8035 / 907-249
www.bora.com
The distribution and duplication of this document, as well as the use and disclosure of its contents are prohibited unless
expressly authorised.
© BORA Lüftungstechnik GmbH, 2015
All rights reserved.
EN
3
Table of Contents
www.bora.com
Table of Contents
1 General 4
2 Safety 6
2.1 General safety precautions .............................. 6
2.2 Safety instructions, operation .......................... 7
2.3 Safety instructions, assembly .......................... 7
2.4
Safety instructions, disassembly and disposal
... 8
2.5 Safety instructions, spare parts ....................... 9
2.6 Use as intended ............................................... 9
3 Technical data 10
4 Energy label 11
5 Device description 12
5.1 Structure ....................................................... 12
5.2 Operating panel and operating principle ....... 12
5.3
Functional principle of the cooktop extractor
... 13
5.3.1 Freely adjustable power control .................... 13
5.3.2 Cover flap sensor .......................................... 13
5.3.3 Automatic after-run ....................................... 13
5.3.4 Filter service display ...................................... 13
5.3.5 Interface communication ............................... 13
5.3.6 Safety shut-down .......................................... 13
6 Installation 14
6.1 Checking the scope of delivery ..................... 14
6.2 Tool and aids ................................................. 14
6.3 Assembly instructions ................................... 14
6.3.1 Safety clearances .......................................... 14
6.4 Cut-out dimensions ....................................... 15
6.5 Installing the extraction system ..................... 16
6.5.1 Installing the control box behind the
floor unit’s fixed front panel .......................... 17
6.5.2 Installing the cooktop extractor and
refitting the exhaust fitting on the left ........... 18
6.5.3
Preparing for installation – standard set-up
... 19
6.5.4 Installation – standard set-up ........................ 20
6.6 Establishing the power connection and
communication .............................................. 21
6.7 Connecting external switch contacts ............ 22
6.8 Handover to user ........................................... 24
7 Operation 25
7.1 Operating the cooktop extractor ................... 25
7.1.1 Opening the cover flap .................................. 25
7.1.2 Adjusting the power level .............................. 26
7.1.3 Automatic after-run ....................................... 26
7.2 Note the filter service function ...................... 26
7.2.1 Closing the cover flap .................................... 26
8 Cleaning and Maintenance 27
8.1 Cleaning agents ............................................. 27
8.2 Cleaning the cooktop extractor ..................... 27
8.2.1 Removing the cover flap, rotating
mechanism and stainless steel grease filter
... 27
8.2.2 Cleaning the cover flap, rotating mechanism
and stainless steel grease filter ..................... 28
8.2.3 Installing the cover flap, rotating mechanism
and stainless steel grease filter ..................... 28
8.3 Cleaning the control knobs ............................ 29
8.4 Replacing the activated charcoal filter .......... 29
9 Troubleshooting 30
10 Decommissioning, disassembly and
disposal 31
10.1 Decommissioning .......................................... 31
10.2 Disassembly .................................................. 31
10.3 Disposing of the product in an
environmentally friendly way ......................... 31
11 Warranty, After Sales Service and
spare parts 32
11.1 Warranty ........................................................ 32
11.2 After Sales Service ........................................ 32
11.3 Spare parts .................................................... 32
12 Notes: 33
EN
4
General
www.bora.com
INFO BORA Holding GmbH, BORA Vertriebs
GmbH & Co KG, BORA APAC Pty Ltd and BORA
Lüftungstechnik GmbH - hereinafter referred
to as BORA - shall not assume any liability for
damage caused by non-compliance with these
documents nor by improper assembly!
The electricity and gas connections must be
implemented by a certified engineer.
Assembly must only take place in compliance
with the applicable norms, regulations and
laws. All safety and warning information and
handling instructions in the operating and
assembly instructions must be followed.
Validity of the operating and assembly
instructions
This manual is valid for several versions of the device. For
this reason, it is possible that individual features are
described in the manual that do not apply to your device.
Other applicable documents
Additional documents are valid as well as these operating
and assembly instructions, and likewise need to be obser-
ved.
Please observe all documents included in the scope of
delivery.
INFO BORA cannot assume any liability for damage
caused by non-compliance with these docu-
ments!
Guidelines
These devices meet the following EC guidelines:
2004/108/EC EMC Directive
2006/95/EC Low-Voltage Directive
2009/125/EC Ecological Design Directive
2010/30/EC Energy label Directive
2011/65/EC RoHS Directive
1 General
Target group
These operating and assembly instructions are intended
for the following target groups:
Target group Requirements
Users The Device may be used by chil-
dren from the age of 8 as well as
by people with limited physical,
sensory or mental capabilities or a
lack of experience and/or knowl-
edge, provided they are super-
vised, have been instructed in the
safe use of the device and have
understood the dangers involved.
Children must be supervised. All
safety and warning information
and handling instructions in the
operating manual must be fol-
lowed.
Ambitious Diyers Ambitious Diyers may carry out all
the necessary carpentry and
assembly work themselves provi-
ding that they have the necessary
skills and knowledge. They must
not connect the current and gas
themselves.
Assembly
expert
The assembly expert must carry
out all the necessary carpentry
and assembly work taking existing
regulations into account. The cur-
rent and gas connections must be
approved for the system in use by
a certified electrician before use.
Electrical
expert
The electrical connection must
only be executed by a certified
electrician. He/she also assumes
responsibility for the proper elec-
trical installation and commission-
ing.
Expert
gas connection
The gas connection must only be
implemented by a certified gas
engineer. He/she also assumes
responsibility for the proper gas
installation and commissioning.
Tab. 1.1: Target groups
EN
5
General
www.bora.com
Depiction of information
We used standard formatting, numbering, symbols, safety
instructions, terms and abbreviations so that you can work
quickly and safely when using this manual.
Instructions are marked with an arrow.
Always perform all instructions in the prescribed
order.
Enumerations are indicated with a square bullet point at
the start of the line.
Enumeration 1
Enumeration 2
INFO Information notes point to special features
that must be taken into account.
Safety and warning instructions
The safety and warning instructions in this manual are em-
phasised with symbols and signal words.
Safety and warning instructions are structured as follows:
WARNING SYMBOL AND SIGNAL
WORD!
Type and source of the danger
Results of non-compliance
Measures to minimise risk
Please note:
The warning symbol draws your attention to the risk.
The signal word indicates the severity of that risk.
Warning
symbol
Signal word Risk
DANGER Indicates an immediate, haz-
ardous situation which
causes death or serious
injury if not respected.
WARNING Indicates a potentially haz-
ardous situation which can
cause death or serious
injury if not respected.
CAUTION Indicates a possible hazard-
ous situation which can
cause minor injury if not
respected.
CAUTION Indicates a situation which
can cause minor injury if not
respected.
Tab. 1.2: Meaning of the warning symbols and signal
words
EN
6
Safety
www.bora.com
INFO In the recirculated air mode, only
a small amount of moisture is
removed from the cooking vapours.
Make sure that the room is sufficiently
ventilated to the outside air in the
recirculated air mode, e.g. through an
open window.
Ensure a normal and comfortable indoor
climate (45-60% humidity), e.g. through
natural ventilation openings or domestic
ventilation systems.
Set the cooktop extractor to a low setting
for about 15 minutes or activate the
automatic after-run after every use in the
recirculated air mode.
When there are children and people with
special needs in the house
This device may be used by children from
the age of 8 as well as by persons with
limited physical, sensory or mental
capabilities or a lack of experience and/or
knowledge, provided they are supervised,
have been instructed in the safe use of
the device and have understood the
dangers involved.
Do not leave children unattended when
they are near the device.
Children must not play with the device.
Do not store any objects that could be of
interest to children in storage spaces
above or behind the device. Otherwise,
the children will be tempted to climb onto
the device.
Unauthorised modifications
Due to unauthorised modifications
The device can constitute a hazard.
Do not make any changes to the device.
Cleaning and Maintenance
The device must be cleaned at regular
intervals. Dirt can lead to damage or odour
nuisance.
Remove dirt immediately.
Any work involving cleaning and user
maintenance must not be carried out by
children unless they are supervised at all
times while doing so.
Do not use a steam cleaner for cleaning.
Steam can cause a short circuit on live
parts and thus lead to property damage
(see the Cleaning chapter).
2 Safety
2.1 General safety precautions
INFO The product complies with the
mandatory safety provisions.
The user is responsible for cleaning,
care and safe use of the device.
Any improper use may lead to
personal injury and property damage.
This operating and installation instructions
contain important information concerning
assembly and operation. It protects you
from injury and prevents damage to the
product. You can find contact data to
get further information and answers to
questions about the use of the product
on the last page of this operating and
installation instructions.
The term "device" is used to refer to
cooktop, cooktop extractor or cooktop
with integrated cooktop extractor.
Read this operating and installation
instructions in full before you assemble
the device and start to use it.
Always keep these operating and
installation instructions to hand so it is
available when needed.
After selling the device, pass on the
operating and installation manual to the
new owner.
Carry out all work with great care and
attention.
Check the device for visible damage after
unpacking.
Do not install a damaged device.
Do not use the device until installation
is complete. Only in this way a safe
operation can be guaranteed.
Make sure contact with hot cooking
surfaces is not possible.
Avoid over-cooking.
Do not, under any circumstances, operate
the cooktop extractor with other cooktops.
Turn the device off after use. Do not rely
on the pan size recognition.
Keep pets away from the device.
Recirculated air mode
INFO Every time the device is used for
cooking, supplementary moisture is
released into the room air.
EN
7
Safety
www.bora.com
WARNING!
Risk of injury due to moving fan
wheel!
There is a risk of injury if the fan
wheel turns.
Only install the device with the
power disconnected.
Connect both sides of the fan
to the duct system before
commissioning.
Ensure that the inlet nozzle is
locked before the device is
commissioned for the first time.
CAUTION!
Touchable parts may become hot!
The cooktop extractor and its
touchable parts are hot when the
cooking zone is switched on and
during the cooling phase.
Do not place any items on the
cooktop.
Please use suitable tools (pot
holders, oven gloves).
CAUTION!
Damage caused by objects or
paper being sucked in!
Small and light objects such as
cleaning wipes made of fabrics or
paper can be sucked into the
cooktop extractor. As a result,
the fan can be damaged or the
fan output can be impaired.
Do not store any objects or
paper on the cooktop extractor.
CAUTION!
Damage caused by fat or dirt
deposits!
Fat or dirt deposits can impair the
functioning of the cooktop extractor.
Never use the cooktop extractor
without a stainless steel grease
filter.
2.3 Safety instructions, assembly
Installation and assembly of the device may
only be carried out by trained personnel who
are familiar with and comply with common
national regulations and supplementary
regulations of the local utility companies.
Do not place any hot cookware in the
area of the control panel so as not to
damage the underlying electronics.
When cleaning the device, water must not
penetrate the interior of the device. Use
only a slightly damp cloth. Never spray
the device with water. Water penetration
can cause damage!
2.2 Safety instructions, operation
Cooktop extractor
DANGER!
Danger to life caused by smoke
poisoning!
Combustion gases arise when
running a replace that depends on
the air in the room.
If you operate the cooktop extractor
with a replace that depends on the
air in the room at the same time,
poisonous combustion gases
(carbon monoxide) may be drawn
from the chimney or extraction duct
into the living room.
Make sure that there is always
enough air supply.
DANGER!
Risk of fire through flambéing!
While in operation, the cooktop
extractor draws o cooking fat.
When ambéing food, the cooking
fat can catch re.
Clean the cooktop extractor at
regular intervals.
Do not carry out any work
involving an open flame when the
cooktop extractor is switched on.
DANGER!
Danger of fire due to grease
deposits!
By failing to clean the stainless
steel grease lter at regular
intervals, increased amounts of
grease may accumulate in it.
This increases the risk of re.
Clean or replace the filters at
regular intervals.
EN
8
Safety
www.bora.com
DANGER!
Risk of electric shock!
Incorrect stripping of the connec-
tion cable to external switching
devices results in a risk of electric
shock.
Ensure that the connection cable
is secured with the strain relief
clamp within the universal con-
trol unit.
Ensure that the stated stripping
lengths are adhered to.
Check the device for visible damages
before installing it.
Do not install a damaged device.
A damaged device may put your safety at
risk!
Repair and maintenance work may only be
carried out by specialists authorised by the
manufacturer.
2.4 Safety instructions, disassembly
and disposal
Disassembly of the device may only be
carried out by trained personnel who are
familiar with and comply with common
national regulations and supplementary
regulations of the local utility companies.
Work on electrical parts may only be carried
out by trained electrical personnel.
DANGER!
Danger of electric shock!
Disconnecting the device
incorrectly from the mains poses a
risk of electric shock.
Safely disconnect the device
from the mains using miniature
or automatic circuit breakers,
fuses or contactors.
Use a suitable measuring device
to ensure that the device is
de-energised.
Work on electrical parts must only be carried
out by trained electrical personnel.
The electrical safety of the device is only
guaranteed if it is connected to a properly
installed protective conductor system. Make
sure that these basic safety precautions have
been taken.
Cooktop extractor
DANGER!
Risk of poisoning caused by
combustion gases!
When the cooktop extractor is used
for exhaust operation, it draws in
air from the room it is installed
in and from neighbouring rooms.
Without sucient air, negative
pressure will occur. Toxic gases
could be drawn out of the chimney
or extraction ducting on a replace
that depends on the room air and
back into the room.
Make sure there is always
enough air supply.
Use technical safety measures
(e.g. window
contact switch, low
pressure warning device) and
have them approved by a
qualified expert (certified
chimney-sweep).
DANGER!
Risk of electric shock!
The electronic unit can contain
residual charge and cause an
electric shock.
Do not touch exposed contacts
on the electronic unit.
EN
9
Safety
www.bora.com
INFO
BORA Holding GmbH,
BORA Vertriebs GmbH & Co KG,
BORA APAC Pty Ltd and
BORA Lüftungs
technik GmbH shall
not assume any liability for damage
arising from non-adherence to the
safety and warning instructions.
DANGER!
Risk of suffocation!
Parts of the packaging (e.g. lms,
polystyrene) can be fatal to children.
Store packaging materials away
from the reach of children.
Dispose of packaging correctly
and promptly.
2.5 Safety instructions, spare parts
WARNING!
Risk of injury and damage to
property!
Incorrect parts can lead to injury
to persons or damage to device!
Modications, attachment parts or
conversions to device can impair
safety.
Only use original spare parts
when carrying out repairs.
2.6 Use as intended
The device is solely intended for preparing
food in private households.
This device is not designed for:
use outdoors
installation in vehicles
heating the room
use in non-fixed installation sites
(e.g. on ships)
use with an external timer or separate
remote control system.
Not using the device as described in this
operating and assembly manual is considered
not using the device as intended, as is using
it beyond the purpose described here.
BORA shall not assume any liability for
damages caused by improper use or incorrect
operation.
All misuse is prohibited!
EN
10
Technical data
www.bora.com
3 Technical data
Parameter Value
Supply voltage 220 - 240 V
Frequency 50 Hz
Power consumption 700 W
Dimensions 110 x 540 x 167 mm
Control box dimensions
(width x depth x height)
96 x 85 x 76 mm
Weight
(incl. accessories/packaging)
5 kg
Cooktop extractor
Power levels 1 - 9
Tab. 3.1: Technical data
Device dimensions
540
110
167
88
223
Abb. 3.1 Device dimensions
41
96
85
38
54
76
27
Abb. 3.2 Control box dimensions
EN
11
Energy label
www.bora.com
4 Energy label
Product description
Professional cooktop extractor system with ULS25 plinth fan PL540E
Operating mode Exhaust air
Energy consumption Value EN standard
Annual energy consumption (AEC
hood
) 26 kWh/a 61591
Energy efficiency class A+ 61591
Flow volume
Fluid dynamic efficiency (FDE
hood
) 39.4 61591
Fluid dynamic efficiency class A 61591
Lighting
Lighting efficiency (LE
hood
) * lx/Watt *
Lighting efficiency class * *
Grease filtering
Level 9 maximum (GFE
hood
) 50% 61591
Class level 9 normal F 61591
Flow volume
Air flow level 1 minimum 232 m³/h 61591
Air flow level 9 maximum (Q
max
) 626 m³/h 61591
Sound power level
Level 1 minimum 44 dB(A) 60704-2-13
Level 9 maximum 67 dB(A) 60704-2-13
Sound pressure level (additional details)
Level 1 minimum 32 dB(A) **
Level 9 maximum 54 dB(A) **
Details according to 66/2014
Power consumption in off mode (P
O
) 0 W 61591
Time increase factor 0.6 61591
Energy efficiency index (EEI
hood
) 32 61591
Air flow rate at the best efficiency point (Q
BEP
) 297 m³/h 61591
Pressure at the best efficiency point (P
BEP
) 548 Pa 61591
Electric power input at the best efficiency point (W
BEP
) 114.7 W 61591
Tab. 4.1: Energy label information
* This specification is not applicable for this product.
** The sound pressure level has been determined from a distance of 1 m (distance-dependent level recording) on the
basis of the sound power level established in EN 60704-2-13.
EN
12
Device description
www.bora.com
5.1 Structure
7
6
5
4
3
2
1
Abb. 5.1 Cooktop extractor
[1] Stainless steel grease filter
[2] Cover flap
[3] Cooktop extractor
[4] Control knob
[5] Power level sleeve
[6] Rotating mechanism
[7] Universal control unit
5.2 Operating panel and operating
principle
1
2
3
Abb. 5.2 Control knob
[1] Control knob
[2] Power level sleeve
[3] Indicator light
5 Device description
Observe all safety and warning information during operation
(see the Safety section).
The cooktop extractor has the following features:
Power control via a control knob
Freely adjustable power control
Cover flap sensor
Automatic after-run
Filter service display
Interface communication
Safety shut-down
Depending on the model you purchased, the cooktop
extractor can be operated as an exhaust air or an recircu-
lating air version.
Exhaust mode
The air extracted from the cooktop is cleaned by the
stainless steel grease filter and released outside through
a duct system.
The exhaust air must not be expelled into:
a smoke or exhaust gas flue that is in operation
a shaft used for the aeration of rooms where
fireplaces are installed.
If the exhaust air is to be directed into a smoke or exhaust
gas flue that is not in use, the installation must be checked
and approved by the responsible heating engineer.
Recirculation mode
The air suctioned away by the cooktop is purified by the
grease filter and an activated charcoal filter and fed back
into the room in which the appliance is installed.
To prevent odours in recirculation mode, an activated
charcoal filter must be used. For hygiene and health
reasons, the activated charcoal filter must be replaced at
the recommended intervals (see the Cleaning and mainte-
nance section).
INFO In recirculation mode, ensure sufficient
ventilation and aeration to expel humidity.
EN
13
Device description
www.bora.com
If the cover flap is closed, the cooktop extractor is
deactivated.
If the cover flap is open, the cooktop extractor can be
used.
If the cover flap is closed during operation, the control
knob must be turned to level 0 before the cooktop
extractor can be re-activated.
5.3.3 Automatic after-run
The cooktop extractor continues to run at a lower level and
switches off automatically after 20 minutes.
5.3.4 Filter service display
The filter service display becomes active after the cook-
top extractor has operated for 400 hours. The activated
charcoal filter has reached the end of its service life (with
recirculation only) and the stainless steel grease filter
needs to be thoroughly cleaned.
The indicator light flashes slowly:
Before and during normal operation
During the automatic after-run period
5.3.5 Interface communication
The internal interface can be used for extended control
options. This has a Home-In and a Home-Out contact (see
the Installation section).
The Home-In contact can be used for the signal input
from external switch devices (e.g. window contact
switch).
The Home-Out contact can be used to control
external installations.
5.3.6 Safety shut-down
The cooktop extractor switches off automatically if no
buttons are pressed for 120 minutes.
Unit Display Meaning
Indicator light On Cooktop extractor is
switched on and operating
Off Cooktop extractor is
switched off
Rapid
flashing
Interface display
Slow
flashing
Filter service display
Power level
sleeve
0 Cooktop extractor off
1 to 9 Setting
x Deactivate the cooktop
extractor
Tab. 5.1: Meaning of display
Knob operation
The operating panel is equipped with a control knob.
To prevent the cooktop extractor from being switched on
accidentally, the control knob is locked at level 0. Press in
the control knob and turn it clockwise to the desired power
level to release the lock (see the Operation section).
5.3 Functional principle of the
cooktop extractor
5.3.1 Freely adjustable power control
The power levels are controlled by turning the control
knob to the desired power level. The interim levels are also
considered when regulating the fan performance.
5.3.2 Cover flap sensor
The cooktop extractor has a sensor in the cover flap area.
This detects the position of the cover flap.
EN
14
Installation
www.bora.com
Dispose of transport packaging in the proper manner
(see the Decommissioning, disassembly and disposal
section).
6.2 Tool and aids
The following tools are required to correctly install the
cooktop extractor:
Pencil
Tape measure
Phillips screwdriver Z2
Standard or cordless drill with Forstner bit Ø30 mm
Drilling template (included in the scope of delivery)
Black, heat-resistant silicone sealant
Fine saw
6.3 Assembly instructions
6.3.1 Safety clearances
1
3
2
Abb. 6.1 Recommended minimum clearances
Maintain the following safety clearances:
[1] Rear minimum clearance of 50 mm between the worktop
cut-out and the rear corner of the worktop.
[2] Minimum clearance of 50 mm from the left and right of
the worktop cut-out to the adjacent cabinet or wall. For
ergonomic reasons and to ensure efficient cooktop extraction,
a minimum clearance of 300 mm is recommended.
[3] Minimum clearance of 700 mm between the worktop
and the wall unit. A minimum clearance of 1000 mm is
recommended for ergonomic reasons.
6 Installation
Observe all safety and warning information
(see the Safety section).
INFO The device must not be installed above cooling
devices, dishwashers, stoves, ovens, washing
machines or dryers.
INFO The contact surfaces of the worktops and
wall sealing strips must be made of a heat-
resistant material (up to approx. 100°C).
INFO Worktop cut-outs must be moisture-sealed
using suitable means or, where necessary,
fitted with a thermal insulator.
INFO If the induction glass ceramic wok is used,
the groove dimensions must be increased to
7 mm for flush installation!
6.1 Checking the scope of delivery
Name Quantity
Control box adjustment plates 6
Control knob 1
Operating and installation instructions 1
Fixing nut 1
Control box fixing screws 2
Drilling template 1
Rotating mechanism 1
Stainless steel grease filter 1
Height adjustment plate set 1
Allen key 1
Cooktop extractor 1
CAT 5 communication cable 1
Power level sleeve 1
Mounting bracket 1
Power supply cable 1
Control box 1
Universal control unit USEE 1
Cover flap 1
Tab. 6.1: Scope of delivery
Check the scope of delivery to make sure everything
has been provided (see table 5.1) and nothing is
damaged.
If there are any missing or damaged parts, please
notify BORA After Sales Service.
Do not under any circumstances install parts which
are damaged.
EN
15
Installation
www.bora.com
Surface mounting
B
<R5
> 74
516
> 700
Abb. 6.4 Surface mounting
12
10 ... 40
Abb. 6.5 Surface mounting cut-out
Cut-out dimensions when installing cooktops only or
cooktops and the cooktop extractor next to each other:
Cooktops/cooktop extractor A in mm B in mm
1/0 374 346
2/0 745 717
3/0 1116 1088
1/1 485 457
2/1 856 828
3/2 1338 1310
4/2 1709 1681
Tab. 6.2: Cut-out dimensions
Adhere the supplied nameplate (adhesive label) to the
back of your operating and installation instructions.
6.4 Cut-out dimensions
Preparing the worktop
Create the worktop cut-out.
Make sure that the cutting surfaces of the worktops
are properly sealed.
Comply with the worktop manufacturer’s instructions.
Flush installation
A
B
544
R5
<R5
> 74
516
> 700
Abb. 6.2 Flush installation
6
14
10 ... 40
Abb. 6.3 Groove dimensions for ush installation
INFO If the induction glass ceramic wok is used,
the groove dimensions must be increased to
7 mm for flush installation.
EN
16
Installation
www.bora.com
187
60
128
Abb. 6.8 Universal control unit installation dimensions
> 700
> 900
> 74
Abb. 6.9 Device installation dimensions
6.5 Installing the extraction system
INFO A clearance of one millimetre should be
planned between the built-in appliances.
INFO A clearance of two millimetres should be
planned around the built-in appliances.
INFO The mounting rail supplied with the cooktop
should be installed between the cooktops as
well as between the cooktops and the cooktop
extractor.
INFO Cable protection (false floor) should be
mounted below the appliances. This needs to
be removable for maintenance work.
> 20
100
7
Abb. 6.6 Side view of the cable protection and ventilation
Cross bars on the kitchen unit in the area of the
worktop cut-out may need to be removed.
The drawers and/or shelves in the floor unit must be
removable for maintenance and cleaning purposes.
There must be a return flow aperture of > 500 cm
2
in
the plinth area for recirculation.
Installation dimensions
540
110
167
88
223
Abb. 6.7 Device dimensions
EN
17
Installation
www.bora.com
Fixed
front
panel
thickness
[mm]
Total thick-
ness of
adjustment
plates
[mm]
Adjustment plates [quantity]
10 mm 5 mm 3 mm 2 mm
34 2 - - - 1
33 3 - - 1 -
32 4 - - - 2
31 5 - - 1 1
30 6 - - 2 -
29 7 - 1 - 1
28 8 - 1 1 -
27 9 - 1 - 2
26 10 1 - - -
25 11 - 1 2 -
24 12 1 - - 1
23 13 1 - 1 -
22 14 1 - - 2
21 15 1 1 - -
20 16 1 - 2 -
19 17 1 1 - 1
18 18 1 1 1 -
17 19 1 1 - 2
16 20 1 1 1 1
15 21 1 1 2 -
14 22 1 1 1 2
13 23 1 1 2 1
Tab. 6.3: Adjustment plate overview
Secure the control box
Position the power level sleeve [4] on the fixed front
panel [3].
Position the control box [1] with the attached
adjustment plates [2] from the back into the bore hole
in the fixed front panel.
Screw on the fixing nut [5] to the mounting bracket
and tighten the fixing nut with max. 10 Nm.
Abb. 6.12 Tighten the xing nut
6.5.1 Installing the control box behind the
floor unit’s fixed front panel
1
2
34
6
5
Abb. 6.10 Control box structure
[1] Control box
[2] Adjustment plates
[3] Fixed front panel (not included in the scope of delivery)
[4] Power level sleeve
[5] Fixing nut
[6] Control knob
Draw the bore hole accordingly with the aid of the
drilling template provided.
1
2
5
>105
37
Ø6
Ø30
Abb. 6.11 Drilling template
[1] Worktop
[2] Fixed front panel
Pre-drill the bore hole to prevent tearing out the panel.
Determining the number of adjustment plates
The total dimensions of the adjustment plates [2] and
the fixed front panel [3] should be 36 mm.
The total dimensions of 36 mm must be adhered to in
order to ensure that the control box [1] functions
smoothly.
EN
18
Installation
www.bora.com
1
2
3
Abb. 6.15 Retting the exhaust tting
[1] Cooktop extractor
[2] Screw
[3] Exhaust fitting
Loosen the five screws [2] on the underside.
Remove the exhaust fitting [3].
1
2
3
Abb. 6.16 Attaching the exhaust tting
[1] Cooktop extractor
[2] Screw
[3] Exhaust fitting
Position the exhaust fitting [3] rotated by 180°.
Fasten the five screws [2].
Make sure that no air gap has formed between the
components.
Put on the control knob [6].
Use the fixing screws provided to screw the control
box onto the fixed front panel in a horizontal position
from the inside. This prevents the control box from
twisting around.
Adjust the control knob
For fine adjustment, the clearance between the contr
ol
knob and the power level sleeve can be set.
Abb. 6.13 Positioning the control knob
18,5 mm
Abb. 6.14 Control knob clearance
6.5.2 Installing the cooktop extractor and
refitting the exhaust fitting on the left
Depending on requirements, the exhaust fitting can slope
down to either the left or the right.
The cooktop extractor’s exhaust fitting is supplied by
default sloping down to the right.
EN
19
Installation
www.bora.com
2
1
Abb. 6.19 Securing the cooktop extractor
[1] Tensioning screw
[2] Clamp
Turn the four clamps [2] under the worktop.
Tighten the clamp screws [1] with max. 10 Nm.
Verify that the alignment is correct.
Once all of the installation work is complete, seal the
devices with black, heat-resistant silicone sealant.
6.5.3 Preparing for installation – standard
set-up
INFO The floor unit must not be supported on the
plinth fan housing.
INFO For correct installation, the slide-in units of the
base cabinet must be shortened depending on
the installation situation.
Now adjust the ducting parts to the height of the
worktop.
Saw out the necessary cut-outs for the ducting in the
rear panel of the floor unit.
Depending on the installation situation, adjust the
levelling feet on the floor unit as necessary.
Prepare the plinth fan by attaching the sealing tape
depending on the installation situation.
Secure the sealing tape to the inlet nozzle.
Installing the cooktop extractor
1
2
Abb. 6.17 Installing the cooktop extractor
[1] Cooktop cut-out
[2] Cooktop extractor
Place the cooktop extractor [2] in the middle of the
relevant worktop cut-out.
Precisely position the cooktop extractor.
1
2
Abb. 6.18 Height adjustment plates
[1] Height adjustment plate
[2] Cooktop extractor
If applicable, insert the height adjustment plates [1].
EN
20
Installation
www.bora.com
6.5.4 Installation – standard set-up
1
2
3
4
5
6
7
Abb. 6.22 Standard set-up
[1] Cooktop extractor
[2] 90° diverter
[3] Horizontal tube bend
[4] Silencer
[5] Universal plinth fan
[6] Air duct/recirculation unit
[7] Universal control unit
Push the tube bend [3] onto the exhaust fitting of the
cooktop extractor [1].
Push the 90° diverter [2] onto the tube bend [3].
Position the plinth fan [5].
To facilitate positioning, the inlet nozzle on the plinth fan
can be removed. To do this, please see the assembly
instructions for the ULS25 universal plinth fan.
Connect the silencer [4] to the plinth fan [5].
Connect the silencer [4] to the 90° diverter [2].
Use the UDB25 sealing tape (not included in the scope
of delivery) to adhere together the connections for the
ducting sections with an air tight join.
You can also optimally adhere together the connections
between the ducting sections and the plinth fan with
UDB25 sealing tape.
INFO Position the plinth fan and the universal
control unit in such a way that they are easily
accessible and removable for maintenance
work.
The maximum exhaust air duct length with a fan is
6 m.
The minimum cross-section of the air ducts must
be 176 cm
2
, which equates to a round pipe with a
diameter of 150 mm.
Abb. 6.20 Sealing tape position for installation with a round duct
Depending on the required connection cross-section,
you can vary the height at which the sealing tape is
attached to the plinth fan inlet nozzle.
Secure the sealing tape on the outlet nozzle.
Abb. 6.21 Sealing tape position for installation with a transition
piece (shallow duct)
INFO When attaching the sealing tape, ensure that
an airtight seal with the connection duct piece
is created when the tape is compressed.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

bora PL540E Operating instructions

Category
Cooker hoods
Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI