Taylor Technologies K-1645-2 Owner's manual

Type
Owner's manual
COMPONENTS:
1 x 5067B Instruction
1 x 9198B Sample Tube, Graduated (25 mL) w/ cap & blue dot, plastic
1 x R-0619B-C Hardness Buffer, 2 oz w/ blue cap, DB
1 x R-0620B-I Hardness Indicator Powder, 10 g w/ blue dot
1 x R-0683-C Hardness Reagent, 2 oz, DB
TO ORDER REPLACEMENT PARTS AND REAGENTS CALL TOLL-FREE
800-TEST KIT (800-837-8548).
PROCEDURE:
CAREFULLY READ AND FOLLOW PRECAUTIONS ON REAGENT LABELS.
KEEP REAGENTS AWAY FROM CHILDREN.
NOTE: When dispensing reagents from dropper bottles, always hold bottle in a
vertical position.
Total Hardness Test
1.Rinseandll25mLsampletube(#9198B)to25mLmarkwithwatertobetested
(Fig.1).
2.Add5dropsR-0619BHardnessBuer.Swirltomix.
3.Add1dipperR-0620BHardnessIndicatorPowder.Swirluntildissolved.Sample
willturnred(Fig.2)ifhardnessispresent.
4.AddR-0683HardnessReagentdropwise,swirlingandcountingaftereachdrop,
untilcolorchangesfromredtoblue(Fig.3).
DROP TEST
TOTAL HARDNESS (1 drop = 10 ppm)
5.MultiplydropsofR-0683HardnessReagentby10.Recordaspartspermillion
(ppm)totalhardnessascalciumcarbonate.
Fig. 1
Fig. 2
Fig. 3
Instr. #5067B
31LovetonCircle,Sparks,MD21152U.S.A.
800-TESTKIT(837-8548)•410-472-4340 7/16
COMPONENTS:
1 x 5067O Instruction
1 x 9198O Sample Tube, Graduated (25 mL) w/ cap & orange dot, plastic
1 x R-0630-C Chromate Indicator, 2 oz, DB
1 x R-0638O-A Phenolphthalein Indicator, .75 oz w/ orange cap, DB
1 x R-0687O-C Sulfuric Acid .12N, 2 oz w/ orange cap, DB
1 x R-0706-C Silver Nitrate Reagent, 2 oz, DB
TO ORDER REPLACEMENT PARTS AND REAGENTS CALL TOLL-FREE
800-TEST KIT (800-837-8548).
PROCEDURE:
CAREFULLY READ AND FOLLOW PRECAUTIONS ON REAGENT LABELS.
KEEP REAGENTS AWAY FROM CHILDREN.
NOTE: When dispensing reagents from dropper bottles, always hold bottle in a
vertical position.
Chloride Test
NOTE: Whensultecontentofsamplewatertobetestedexceeds10ppm,the
sulteshouldbeoxidizedtopreventinterferenceintest.A25mLwater
sampleisrst adjusted to the appropriatepH,then1mL(or25 drops)
of R-0649 Hydrogen Peroxide Solution (sold separately) is added and
thoroughlymixed.Continuewiththerestoftheprocedure.
1.Rinseandll25mLsampletube(#9198O)to25mLmarkwithwatertobetested.
2.Add2dropsR-0638OPhenolphthaleinIndicator.Swirltomix.Ifsampleturns
pink(Fig.1),addR-0687OSulfuricAcid.12Ndropwise,swirlingaftereachdrop,
untilcolorchangesfrompinktocolorless.
DROP TEST
CHLORIDE (1 drop = 10 ppm)
3.Add5dropsR-0630ChromateIndicator.Swirltomix.Samplewillturnyellow
(Fig.2).
4.AddR-0706SilverNitrateReagentdropwise,swirlingandcountingaftereach
drop,untilcolorchangesfromyellowtomilkysalmon(brick)red(Fig.3).
NOTE: DonotaddenoughR-0706SilverNitrateReagenttogiveabrowncolor.
Firstchangefromyellowtoamilkysalmon(brick)redistheendpoint.
5.MultiplydropsofR-0706SilverNitrateReagentby10.Recordaspartspermillion
(ppm)chloride.
Fig. 1
Fig. 2
Fig. 3
Instr. #5067O
31LovetonCircle,Sparks,MD21152U.S.A.
800-TESTKIT(837-8548)•410-472-4340 8/16
COMPONENTS:
1 x 5067G Instruction
1 x 9198G Sample Tube, Graduated (25 mL) w/ cap & green dot, plastic
1 x R-0637-C Methyl Orange Indicator, 2 oz, DB
1 x R-0638G-A Phenolphthalein Indicator, .75 oz w/ green cap, DB
1 x R-0645-C Total Alkalinity Indicator, 2 oz, DB
1 x R-0687G-C Sulfuric Acid .12N, 2 oz w/ green cap, DB
TO ORDER REPLACEMENT PARTS AND REAGENTS CALL TOLL-FREE
800-TEST KIT (800-837-8548).
PROCEDURE:
CAREFULLY READ AND FOLLOW PRECAUTIONS ON REAGENT LABELS.
KEEP REAGENTS AWAY FROM CHILDREN.
NOTE: When dispensing reagents from dropper bottles, always hold bottle in a
vertical position.
P/M Alkalinity Test
1.Rinseandll25mLsampletube(#9198G)to25mLmarkwithwatertobetested.
NOTE: Forresultsingrainspergallon(gpg),llto14.6mLmark.
2.Add3dropsR-0638GPhenolphthaleinIndicator.Swirltomix.Samplewillturn
pink(Fig.1)ifPalkalinityispresent—proceedtoStep3.Ifsampleiscolorless,
proceedtoStep4.
3.AddR-0687GSulfuricAcid.12Ndropwise,swirlingandcountingaftereachdrop,
untilcolorjustchangesfrompinktocolorless.RecorddropsasPreading.
DROP TEST
P/M & P/T ALKALINITY (1 drop = 10 ppm)
Fig. 1
Fig. 2
Fig. 3
Instr. #5067G
(OVER)
4.Add5dropsR-0637MethylOrangeIndicator.Swirltomix.Samplewillturnyellow
(Fig.2).
5.Add R-0687G Sulfuric Acid .12N dropwise, swirling and counting after
each drop, until color changes from yellow to orange (salmon pink)
(Fig.3).Recordtotaldrops(Steps3&5)asMreading.
6.MultiplyPreadingby10.Recordaspartspermillion(ppm)Palkalinityascalcium
carbonate.Multiply M readingby10. Recordas ppm Malkalinity as calcium
carbonate.
NOTE: For 14.6 mL sample, record P reading as grains per gallon (gpg) P
alkalinityascalciumcarbonate.RecordTreadingasgpgTalkalinityas
calciumcarbonate.
P/T Alkalinity Test
1.Rinseandll25mLsampletube(#9198G)to25mLmarkwithwatertobetested.
NOTE: Forresultsingrainspergallon(gpg),llto14.6mLmark.
2.Add3dropsR-0638GPhenolphthaleinIndicator.Swirltomix.Samplewillturn
pink(Fig.4)ifPalkalinityispresent—proceedtoStep3.Ifsampleiscolorless,
proceedtoStep4.
3.AddR-0687GSulfuricAcid.12Ndropwise,swirlingandcountingaftereachdrop,
untilcolorjustchangesfrompinktocolorless.RecorddropsasPreading.
4.Add5dropsR-0645TotalAlkalinityIndicator.Swirltomix.Samplewillturngreen
(Fig.5).
5.ContinueaddingR-0687GSulfuricAcid.12Ndropwise,swirlingandcounting
aftereachdrop,untilcolorchangesfromgreentored(Fig.6).Recordtotaldrops
(Steps3&5)asTreading.
6.Multiply P reading by 10. Record as parts per million (ppm) P alkalinity as
calcium carbonate. Multiply T reading by 10. Record as ppm T alkalinity as
calciumcarbonate.
NOTE: For 14.6 mL sample, record P reading as grains per gallon (gpg) P
alkalinityascalciumcarbonate.RecordTreadingasgpgTalkalinityas
calciumcarbonate.
DROP TEST
P/M & P/T ALKALINITY (1 drop = 10 ppm)
Fig. 4
Fig. 5
Fig. 6
31LovetonCircle,Sparks,MD21152U.S.A.
800-TESTKIT(837-8548)•410-472-4340 8/16
Instr. #5067G