Navigator 1 Thermostat Installer Parameters
Parameter Id Value Meaning
Temperature Display Zone 3 1 Displaying temperature in zone 1
Temperature Measurement –
Common Zone
4 0 No measurement from common zone
Temperature Measurement –
Switched Zones
5 3 Measuring zones 1 & 2
Navigator 2 Thermostat Installer Parameters
Parameter Id Value Meaning
Temperature Display Zone 3 3 Displaying temperature in zone 3
Temperature Measurement –
Common Zone
4 0 No measurement from common zone
Temperature Measurement –
Switched Zones
5 12 Measuring zones 3 & 4
NOTE: There is no difference in setup between a wall mounted wired and wireless
remote Navigator installation.
LTIPLE CONTROLLERS – INDIVIDUAL ZONES (Example)
This feature allows each controller on the navigator system to be assigned to a zone
or a group of zones that is not assigned to any other controller on the system. In this
configuration, there is no interaction between controllers. Each has complete
independent control over its zones and the program set on that control is unique to
that controller and zone. In this mode, you will NOT assign any controller to the
common or unswitched zone.
To enable this feature, Multiple Controllers in individual zones, the system
configuration parameter must be set to 3 (Individual) on all controllers. Best results
will be achieved when one Navigator controller is assigned to zones 1 & 2, the other
to zones 3 & 4. The common zone must be disabled. This assumes that the
Navigators are physically installed in Zones 1 and 3 respectively.
Navigator 1 Controller Installer Parameters
Parameter Id Value Meaning
Unswitched Zone 1 0 Common zone disabled
Switched Zones 2 3 Controlling Zones 1 & 2
Temperature Display Zone 3 1 Displaying temperature in zone 1
Temperature Measurement –
Common Zone
4 0 No measurement from common zone
Temperature Measurement –
Switched Zones
5 3 Measuring zones 1 & 2
Navigator 2 Controller Installer Parameters
Parameter Id Value Meaning
Unswitched Zone 1 0 Common zone disabled
Switched Zones 2 12 Controlling Zones 3 & 4
Temperature Display Zone 3 3 Displaying temperature in zone 3
Temperature Measurement –
Common Zone
4 0 No measurement from common zone
Temperature Measurement –
Switched Zones
5 12 Measuring zones 3 & 4