Intertherm PVC Isolation Kit #904063 Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Intertherm PVC Isolation Kit #904063 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
2"-3" Transition
Vent Pipe
Hose Clamp
PVC
Isolation
Tube
PVC Isolation Kit 904063
M3 Series
Figure 1. PVC Isolation Tube Assembly
IMPORTANT:
Read these instructions and the M3RL
Installation Instructions carefully for general
installation requirements before beginning the
installation.
NOTE:
This installation Instructions has been written
based on furnace not installed.
Contents of Kit:
1. 3" diameter PVC isolation tube – 2 pcs.
2. Installation Instructions.
Installing the kit: (See Figure 1)
1. Slide the 3" diameter PVC isolation tube
(rear most) on the PVC vent pipe through
the top panel hole and fit 2" to 3" transition
boot on vent pipe until it touches isolation
tube.
2. Tighten hose clamp on 2" to 3" rubber
connection boot. Note: Please verify that
the hose clamp is tightened well to prevent
leaking flue gas and condensate.
3. Repeat steps #1-#2 for the combustion air
intake (front most) pipe.
INSTALLATION INSTRUCTIONS
7085470 (Replaces 7082600)
Specifications & illustrations subject to change without notice or incurring obligations (05/15).
O’Fallon, MO, © Nortek Global HVAC LLC 2015. All Rights Reserved.
/