Avaya 1151C1/1151C2 User manual

Type
User manual
1
1151C1/1151C2 Power Supply
Installation and Safety Instructions
IMPORTANT USER SAFETY INSTRUCTIONS
The most careful attention has been devoted to quality standards in the manufacture of
your new power supply. Safety is a major factor in the design of every Avaya Product.
But, safety is YOUR responsibility too. Please read carefully the helpful tips listed
below. These suggestions will enable you to take full advantage of this product. Then,
retain these tips for later use.
!
WARNING:
This product is NOT for residential use. It is for business systems applications
ONLY.
Use
When using your power supply, the following safety precautions should always be
followed to reduce the risk of fire, electric shock, and injury to persons.
Read and understand all instructions.
Follow all warnings and instructions marked on the product and contained in its
packaging.
The 1151C1/C2 Power Supplies are for use only with specified Avaya equipment as
outlined in the attached materials or available on
http://www.avaya.com/support.
No other use of the 1151C1/C2 Power supplies is recommended or warranted
The equipment must not be connected to TNV-3 (standard analog phone lines) or
TNV-2 circuits.
For Australia, the equipment must not be connected to any TNV circuit.
The equipment must not be installed in proximity to standard phone lines.
This device can be hazardous if immersed in water. Do not use this product near
water, for example, near a bath tub, wash bowl, kitchen sink or laundry tub, in a wet
basement or near a swimming pool. To avoid the possibility of electric shock, do not
use it while you are wet. If you accidentally drop the power supply into water, do not
retrieve it until you have first unplugged the line cord from the modular wall jack,
unplugged the power cord from the AC wall receptacle (or other AC power source),
and unplugged the output cable from any device powered by the supply. Then, call
service personnel to ask about a replacement.
This product should be operated only from the type of AC power indicated on the
product label. If you are unsure of the type of AC power being provided, contact a
qualified service person.
Do not allow anything to rest on the power cord. Do not locate this product where
the cord will be abused, such as by persons walking on it.
Allow adequate ventilation for the product. Do not cover or install in a confined
space that may prevent cooling and allow excessive heat build-up.
To reduce the risk of electric shock, do not disassemble this product. There are no
user serviceable parts. Opening or removing covers may expose you to hazardous
voltages. Incorrect reassembly can cause electric shock when the product is
subsequently used.
The Avaya model 1151C2 power supply contains a non-spillable sealed lead-acid
battery. Reasonable care should be taken to avoid puncturing, or otherwise
compromising the integrity of the battery housing. Recycle the battery properly.
!
CAUTION:
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
Service
Before cleaning or removing from service, unplug the power supply from the
modular wall jack, unplug the power cord from the AC wall receptacle (or other AC
power source), and unplug the output cable from any device powered by the
supply. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for
cleaning.
Be sure to disconnect all cords from this product and refer servicing to qualified
service personnel when these conditions exist:
If the power supply cord is damaged or frayed.
If liquid has been spilled into the product.
If the product has been exposed to rain or water.
If the product has been dropped or the housing has been damaged.
If you note a distinct change in the performance of the product.
Declaration of Conformity
To download the Declaration of Conformity (DoC) for this equipment, visit
http://www.avaya.com/support
SAVE THESE INSTRUCTIONS
When you see this warning symbol on the product, refer to
this instructions booklet for more information before
proceeding.
!
16-600743
Issue 3, September 2008
12
Copyright 2008, Avaya Inc.
All Rights Reserved
Notice
Every effort was made to ensure that the information in this document
was complete and accurate at the time of printing. However, information
is subject to change.
Warranty
Avaya Inc. provides a limited warranty on this product. Refer to your
sales agreement to establish the terms of the limited warranty. In
addition, Avaya's standard warranty language as well as information
regarding support for this product, while under warranty, is available
through the following Web site: http://www.avaya.com/support
.
Disclaimer
Avaya is not responsible for any modifications, additions or deletions to
the original published version of this documentation unless such
modifications, additions or deletions were performed by Avaya. Customer
and/or End User agree to indemnify and hold harmless Avaya, Avaya's
agents, servants and employees against all claims, lawsuits, demands
and judgments arising out of, or in connection with, subsequent
modifications, additions or deletions to this documentation to the extent
made by the Customer or End User.
Standards Compliance
Avaya Inc. is not responsible for any radio or television interference
caused by unauthorized modifications of this equipment or the
substitution or attachment of connecting cables and equipment other
than those specified by Avaya Inc. The correction of interference caused
by such unauthorized modifications, substitution or attachment will be the
responsibility of the user. Pursuant to Part 15 of the Federal
Communications Commission (FCC) Rules, the user is cautioned that
changes or modifications not expressly approved by Avaya Inc. could
void the user's authority to operate this equipment.
How to Get Help
For additional support telephone numbers, go to the Avaya support Web
site: http://www.avaya.com/support
. If you are:
Within the United States, click the Escalation Contacts link
that is located under the Support Tools heading. Then click
the appropriate link for the type of support that you need.
Outside the United States, click the Escalation Contacts link
that is located under the Support Tools heading. Then click
the International Services link that includes telephone
numbers for the international Centers of Excellence.
Product Safety Standards
This product complies with and conforms to the following international
Product Safety standards as applicable:
Safety of Information Technology Equipment, IEC 60950-1,
1st Edition, including all relevant national deviations as listed
in Compliance with IEC for Electrical Equipment (IECEE)
CB-96A.
Safety of Information Technology Equipment, CAN/
CSA-C22.2 No. 60950-1-03 / UL 60950-1, 1st Edition.
Safety Requirements for Information Technology Equipment,
AS/NZS 60950:2000.
One or more of the following Mexican national standards, as
applicable: NOM 001 SCFI 1993, NOM SCFI 016 1993, NOM
019 SCFI 1998
This product may also comply with and conform to other national,
regional or commonly recognized product safety standards. For
information regarding specific standards, check the product label or
contact your local Avaya representative.
Electromagnetic Compatibility (EMC) Standards
This product complies with and conforms to the following international
EMC standards and all relevant national deviations:
Limits and Methods of Measurement of Radio Interference of
Information Technology Equipment, CISPR 22:1997,
EN55022:1998, and AS/NZS 3548.
Information Technology Equipment - Immunity
Characteristics - Limits and Methods of Measurement,
CISPR 24:1997 and EN55024:1998, including:
Electrostatic Discharge (ESD) IEC 61000-4-2
Radiated Immunity IEC 61000-4-3
Electrical Fast Transient IEC 61000-4-4
Surge Immunity IEC 61000-4-5
Conducted Immunity IEC 61000-4-6
Power Frequency H-Field Immunity IEC 61000-4-8
Voltage Dips & Variations Immunity IEC 61000-4-11
Federal Communications Commission Statement, Part 15:
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
USA FCC CFR 47 part 15
Federal Communication Commission (FCC) Radio Frequency Devices,
Sub part B Unintentional Radiators: Sections 15.107 & 15.109. Class B
Device Declaration / User Statement Note:
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC rules. These limits
are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following
measures.
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
Consult the dealer or an experienced radio / TV technician for
help.
Declaration of Conformity (DoC) statement is available on the Avaya
external web site: http://support.avaya.com/elmodocs2/DoC/
Reference Power Supplies.
European Union Declarations of Conformity
Avaya Inc. declares that the equipment specified in this
document bearing the “CE” (Conformité Europeénne)
mark conforms to the European Union Radio and
Telecommunications Terminal Equipment Directive (1999/
5/EC), including the Electromagnetic Compatibility Directive (89/336/
EEC) and Low Voltage Directive (73/23/EEC).
Copies of these Declarations of Conformity (DoCs) can be obtained by
contacting your local sales representative and are available on the
following Web site: http://www.avaya.com/support
.
Japan
This is a Class B product based on the standard of the Voluntary Control
Council for Interference by Information Technology Equipment (VCCI). If
this equipment is used in a domestic environment, radio disturbance may
occur, in which case, the user may be required to take corrective actions.
Other
The above statements of compliance and conformity to various product
safety and EMC standards may not be complete, and are subject to
change. Changes may occur as certifications, listings, approvals, etc. are
obtained or removed in accordance with various national and/or regional
requirements. Applicable certification, listing, agency, and other such
symbols and/or marks are often required to be visible on the product and
may in many cases be used as a visual indication that the product has
been tested and approved under the requirements of the associated
country, organization, agency, certification body, etc. Checking the power
supply markings is a good first step in determining which agency
approvals have been granted. For inquiries regarding specific
certifications, contact your local or regional Avaya representative.
To order copies of this and other documents:
Call: Avaya Publications Center
Voice 1.800.457.1235 or 1.207.866.6701
FAX 1.800.457.1764 or 1.207.626.7269
Write: Globalware Solutions
200 Ward Hill Avenue
Haverhill, MA 01835 USA
Attention: Avaya Account Management
For the most current versions of documentation, go to the Avaya support
Web site: http://www.avaya.com/support
.
13
Sources of Information
For information about an 1151C1 or 1151C2 power supply or instructions
on how to install it, refer to this instruction booklet packed with the
product. Additional installation information may often be found in the user
or installation manual of the terminal or adjunct equipment used with the
power supply. As the 1151C1 and 1151C2 are third generation power
supplies, the original product manuals may describe use with the prior
generation 1151A1/A2 or 1151B1/B2 models. The models 1151C1 and
1151C2 are direct replacements for these legacy Avaya and Lucent
models and may be substituted for them. (Please note that although the
physical appearance of the power supplies have changed, the basic
functionality has remained the same.)
Power Supply Description
The 1151C1 power supply is a “desktop”, single output 48 volt dc, 20 watt
power supply. The power supply can operate over a wide range of AC
input voltage and frequency: 90 - 264 VAC, 47-63 Hz.
The 1151C2 power supply is a “desktop “, single output 48 volt dc, 20
watt power supply with battery holdover. The power supply can operate
over a wide range of AC input voltage and frequency: 90 - 264 VAC, 47
63 Hz. When AC power fails the battery (if fully charged) should provide
approximately 15 minutes of holdover at full load (20 watts) or about 8
hours at light load (2 watts). As many factors may impact battery
performance (such as level of charge, age of the battery, temperature,
etc.), actual performance will vary.
The 1151C1/C2 Power Supplies
The 1151C1/C2 Power Supplies can be used to supply local power to the
following Lucent or Avaya products:
Adjunct equipment such as the EU24, EU24BL (when
attached to a compatible DCP telephone);
DCP compatible Expansion Modules such as the XM24, 1EM
or 2EM, and other optional equipment including the 100A
Analog Interface Module, 20A Stand with 200A Analog
Adjunct Interface and/or 201A Recorder Interface Modules
installed on DCP phones;
DCP Voice Terminal Series 64xx, 74xx and 84xx when
needed for powering optional adjuncts, or where required as
for the model 8411;
DCP 7444 and 8434 voice terminals which need auxiliary
power for their vacuum fluorescent displays;
Adjunct equipment such as the S201A and CS201A
speakerphones or a 500A Headset Adapter attached to any
Analog, DCP, or ISDN-T voice terminal equipped with an
Adjunct jack;
MLX-20L™, MLX-20LS™, MLX-28D™, MLX-28DS™
telephones connected to a Lucent or Avaya MERLIN
LEGEND
®
Communications System;
MLS-CA24 Call Assistant™ Intercom Autodialer (DSS) and
the Remote Access Unit connected to a Lucent or Avaya
PARTNER
®
Communications System;
ISDN-T 65xx, 75xx, and 85xx series voice terminal
connected to a Lucent or Avaya DEFINITY
®
Communications
System.
Note: Failure to use and install as directed could result in injury. No other
use of the 1151C1/C2 Power supplies is recommended or warranted. At
the time of publication, every effort has been made to insure accuracy of
this manual. However, it is possible that 1) some omissions have
occurred, or 2) new products have since been introduced that use the
1151C1 or 1151C2 power supply. If you are unsure concerning the
suitability of models 1151C1 or 1151C2 for a particular application, check
your product documentation or contact your local Avaya representative
for assistance.
!
CAUTION:
The 1151C1 and 1151C2 Power Supplies can only be used with
telecommunications equipment, indoors, in a controlled environment.
Operation
The maximum loop range between the telephone and the power supply
is 14 feet.
This power supply is intended to replace the MSP-1, 329A, 353A,
1151A1/A2 and the 1151B1/B2 DC power supplies, the Definity Adjunct
Power Kit (consisting of the KS-22911-L1/2 Plug-In Power Supply,
D6AP-87 cord and 400B2 adapter), and the 2012D AC transformer.
The 1151C1 power unit has a green LED that shows the unit has power
on the PHONE jack, pins 7 & 8 when AC power is applied.
The 1151C2 power unit has two LED's: a green LED that shows the unit
has power on the PHONE jack, pins 7 & 8 when AC power is applied or
running on battery and a YELLOW LED that shows the unit is charging
the battery when illuminated. When blinking, the GREEN LED indicates
that the unit is running on battery power.
The 1151C2 incorporates a new integrated feature that allows one to
easily disable the output when the supply is disconnected from AC mains
power. This allows storage of the power supply without rapid discharging
of the internal sealed Lead-acid battery due to continued operation of the
internal battery-voltage to output-voltage converter (henceforth referred
to as the “boost converter”). After disconnecting the 1151C2 power
supply from the AC mains following 1) normal use, or 2) periodic
recharge maintenance of the internal battery, the user should do the
following:
Locate the disable-switch access hole on the base of the
1151C2 power supply. Insert a fine non-metallic object (such
as a wooden or plastic toothpick) into the access hole and
depress the recessed momentary contact switch. This
operation disables the internal boost converter. Once the
boost converter is disabled, all status LEDs will turn off (this
may take a few seconds as the stored charge in the output
filter capacitors is discharged). This operation should only be
done when the power supply is to be stored or is to go
through a period of non-use.
Note: One should not press the disable button when the supply is in
active operation during a power failure. Once the boost converter disable
button is pressed, the supply will no longer function until AC mains power
is restored. When AC mains power is restored to the power supply,
normal operation will resume.
Maintenance
The Avaya models 1151C1/C2 power supplies contain no user
serviceable parts. To reduce the risk of electric shock, do not
disassemble the product.
To clean the 1151C1/C2 power supply, first unplug the AC power cord
from the wall receptacle (or other AC source) and disconnect all cords
from the Line and Phone RJ45 jacks. Do not use liquid cleaners or
aerosol cleaners. Use a damp cloth for cleaning.
Like all batteries, the internal Lead-acid battery of the 1151C2 power
supply will self-discharge over a period of inactivity and must be
periodically recharged to avoid damage. This is not a concern during
normal supply operation, as the power supply will automatically recharge
as needed. However, when stored and disconnected from the AC mains
for an extended period of time, the battery should be recharged every six
months to prolong battery life and avoid damage resulting from deep
discharge. This may be done by simply connecting the power supply to a
source of AC power and allowing the battery to charge for at least twelve
hours. When battery charging is complete, if the power supply is to be
placed back into storage or disconnected again from the AC mains, one
should immediately disable the battery boost converter as outlined in the
“Operation” section above.
Contents of the 1151C1 and 1151C2 Boxes
*If a longer network cable is desired, a 4.26m (14 ft) Cat5e patch cable is
available for purchase from Avaya using comcode: 700204050.
Connecting the Power Supply
The power output is provided through a modular jack on the power
supply. These jacks are labeled as follows:
The supply output is essentially isolated from earth ground and
depending on the particular application, either output pin may be used to
establish a reference potential. However, it is common in
telecommunications applications to think of the supply output as nominal
-48Vdc (pin 7) relative to a 0Vdc reference on pin 8.
The output jack, labeled “IP/DCP PHONE” is an 8-pin female non-keyed
RJ45 jack that can accept D8W and RJ45 modular plug cables.
The input jack, labeled “LAN/DCP” is an 8-pin female non-keyed RJ45
jack that can accept RJ45 modular plug cables, such as Cat5 (LAN) or
Cat3 (DCP line) cables. A Cat5e cable fitted with RJ45 modular plugs is
provided with the supply and may often be used in place of a D8W type
cable if desired.
1151C1
Quantity Comcode
1 1151C1 Power Supply 700356447
1 1.9 m (6.23 ft) Cat5 Network Cable*
1 Installation & Safety Instructions
1151C2
Quantity Comcode
1 1151C2 Power Supply 700356454
1 1.9 m (6.23 ft) Cat5 Network Cable*
1 Installation & Safety Instructions
IP/DCP
PHONE LAN/PBX
14
The following local powering arrangements, shown in Figures 1 - 4, can
be used with the 1151C1/C2 Power Supplies:
Figure 1 shows the local powering arrangement for the
model 7444 voice terminal, and for models 2420, 6416, 6424
and CALLMASTER
®
telephones when used with an adjunct.
This arrangement is also used for the 302D attendant
consoles. This arrangement can also be used on legacy
terminals where the 1151A or 1151B were recommended.
Figure 2 shows the local powering arrangement for MERLIN
LEGEND telephones.
Figure 3 shows the local powering arrangement for a
PARTNER MLS-CA24 DSS.
Figure 4 shows the local powering arrangement for a
PARTNER Remote Access Unit.
Note: The type of cord(s) needed to make these connections are
designated in each drawing.
Trademarks
CALLMASTER, DEFINITY, MERLIN, MERLIN LEGEND, and PARTNER
are registered trademarks of Avaya Inc. MLX-20L, MLX-20LS, MLX-28D,
and MLX-28DS are trademarks of Avaya in the U.S. and other countries.
Avaya Limited Warranty
What is covered: Any defect in materials or workmanship.
For how Long: One year.
What will we do: If your Avaya product is defective in material and
workmanship and is returned within one year of date it was purchased,
we will repair it or, at our option, replace it at no charge to you.
What we ask you to do: To get warranty service for Avaya product, you
must provide proof of the date of purchase.
15
Figure 1: Local Powering Arrangement for Model 7444, and for 2420, 6416, 6424 and CALLMASTER
®
Telephones when Used with an Adjunct
16
Figure 2: Local Powering Arrangement for MERLIN LEGEND
®
Telephones
17
Figure 3: Local Powering Arrangement for a PARTNER
®
MLS-CA24 DSS
18
Figure 4: Local Powering Arrangement for a PARTNER
®
Remote Access Unit
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

Avaya 1151C1/1151C2 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI