© 2022 Branson Ultrasonics Corporation Page 2 of 2 4000841, REV. 01
DCX S-Series Power Supply - Quick Start Guide
I/O Connections (26-pin HD D-Sub Connector)
Typical Digital I/O Wiring Examples:
User I/O Connector Pin Assignments*
* This table shows the default pin assignments. Pins 1-4, and 7-10 can be configured using the DCX
PIN I/O Type Function Values
1 Input Digital External Start Apply +24 VDC to run cycle
2 Input Digital External Seek Apply +24 VDC to perform a seek
3 Input Digital External Reset Apply +24 VDC to reset alarm
4 Input Digital Memory Clear Apply +24 VDC to clear memory
5I/O Signal
Source
+24 VDC Source
from DCX S +24 V, 250 mA max. supplied from DCX S
6
7 Output Digital Ready +24 V indicates the system is ready
8 Output Digital Sonics Active +24 V indicates ultrasonics are active
9 Output Digital General Alarm +24 V indicates an alarm occurred
10 Output Digital Seek/Scan Out +24 V indicates Seek/Scan in progress
14 I/O Signal
Return
+24 VDC Return
and I/O Return
Return for all pins except pins 17, 18, 24,
and 25
15
17 Input Analog Amplitude In 1 V to + 10 V (10 % to 100 %)**
web page interface. Consult your power supply manual for details on configuring digital I/O functions.
**If the input signals are not within their valid range, or if left unconnected, the power supply will use
50 % amplitude and zero frequency offset, respectively.
18 Input Analog Frequency Offset 1 V to + 9 V (5 V is zero offset)**
24 Output Analog Power Out 0 V to + 10 V (0 % to 100 %)
25 Output Analog Amplitude Out 0 V to + 10 V (0 % to 100 %)
26 Analog Signal
Return
Analog Signal
Return Return for pins 17, 18, 24, and 25
Typical Analog I/O Wiring Examples:
Front Panel Interface
Test the Equipment
To test the power supply for proper operation, follow the steps listed below:
• Ensure that no one is in contact with the horn when testing the power supply
• Do not cycle the welding system if either the RF cable or converter is disconnected
1. Ensure the power supply is properly connected, as indicated in Section “Connect
the Power Supply” on page 1.
2. Turn on the power supply. The front panel Power LED and LCD turn on.
3. Press the Ultrasonic Test Key for 1-2 seconds, then release. The Sonics Active Indi-
cator appears while the Ultrasonic Test Key is pressed.
4. If the Alarm Indicator Icon begins flashing, press the Alarm Reset Key and repeat
step 3 one time only. If the alarm persists consult your power supply manual.
DCX Web Page Interface Default IP Address:
IP address: 192.168.10.100 Subnet Mask: 255.255.255.0
Item Description
1 Amplitude Setting
2 Sonics Active Indicator
3 Alarm Reset Key
4 Alarm Indicator Icon
5 Configuration Key
6 Ultrasonic Test Key