EuroLite PAR-64 Profi Spot User manual

Category
Stroboscopes & disco lights
Type
User manual
© Copyright
Nachdruck verboten!
Reproduction prohibited!
Für weiteren Gebrauch aufbewahren!
Keep this manual for future needs!
BEDIENUNGSANLEITUNG
USER MANUAL
LED PAR-64
RGB Floor Spot
RGB Short Spot
00066216, Version 1.2 2/23
Inhaltsverzeichnis / Table of contents
EINFÜHRUNG ................................................................................................................................................... 3
SICHERHEITSHINWEISE ................................................................................................................................. 3
BESTIMMUNGSGEMÄßE VERWENDUNG ..................................................................................................... 5
GERÄTEBESCHREIBUNG .............................................................................................................................. 6
Features ......................................................................................................................................................... 6
INSTALLATION ................................................................................................................................................ 6
Überkopfmontage ........................................................................................................................................... 6
DMX512-Ansteuerung ................................................................................................................................... 8
Master/Slave-Betrieb ..................................................................................................................................... 8
Anschluss ans Netz ........................................................................................................................................ 9
BEDIENUNG ..................................................................................................................................................... 9
STAND ALONE-MODUS ............................................................................................................................... 9
Einstellung der festen Farben ........................................................................................................................ 9
Interne Programme, Musiksteuerung ........................................................................................................... 10
Einstellung der Mikrofonempfindlichkeit....................................................................................................... 10
DMX MODUS ............................................................................................................................................... 10
Adressierung des Geräts ............................................................................................................................. 10
Auswählen eines DMX-Kanal-Modus mit 3- oder 5-Kanal-Belegung .......................................................... 11
DMX-Protokoll .............................................................................................................................................. 11
REINIGUNG UND WARTUNG ........................................................................................................................ 12
Sicherungswechsel ...................................................................................................................................... 12
TECHNISCHE DATEN .................................................................................................................................... 13
INTRODUCTION ............................................................................................................................................. 14
SAFETY INSTRUCTIONS .............................................................................................................................. 14
OPERATING DETERMINATIONS .................................................................................................................. 16
DESCRIPTION ................................................................................................................................................ 17
Features ....................................................................................................................................................... 17
INSTALLATION .............................................................................................................................................. 17
Overhead rigging .......................................................................................................................................... 17
DMX512 control ........................................................................................................................................... 18
Master/Slave-Operation ............................................................................................................................... 19
Connection with the mains ........................................................................................................................... 19
OPERATION ................................................................................................................................................... 20
STAND ALONE-MODE ................................................................................................................................ 20
Setting Solid Colors...................................................................................................................................... 20
Internal Programs, Sound Control ............................................................................................................... 20
Setting the Sound Sensitivity: ...................................................................................................................... 20
DMX MODE ................................................................................................................................................. 21
Addressing ................................................................................................................................................... 21
Choosing a DMX Channel Mode with 3 or 5 Channal Occupation .............................................................. 21
DMX-protocol ............................................................................................................................................... 22
CLEANING AND MAINTENANCE ................................................................................................................. 22
Replacing the fuse ....................................................................................................................................... 22
TECHNICAL SPECIFICATIONS ..................................................................................................................... 23
Diese Bedienungsanleitung gilt für die Artikelnummern: / This user manual is valid for the article numbers:
51913961, 51913962, 51913981, 51913982
Das neueste Update dieser Bedienungsanleitung finden Sie im Internet unter:
You can find the latest update of this user manual in the Internet under:
www.eurolite.de
00066216, Version 1.2 14/23
USER MANUAL
PAR-64
RGB Floor Spot ~ RGB Short Spot
CAUTION!
Keep this device away from rain and moisture!
Never open the housing!
For your own safety, please read this user manual carefully before you initially start-up.
Every person involved with the installation, operation and maintenance of this device has to
- be qualified
- follow the instructions of this manual
- consider this manual to be part of the total product
- keep this manual for the entire service life of the product
- pass this manual on to every further owner or user of the product
- download the latest version of the user manual from the Internet
INTRODUCTION
Thank you for having chosen a EUROLITE LED PAR-64 RGB Floor/Short. If you follow the instructions given
in this manual, we are sure that you will enjoy this device for a long period of time.
Unpack your LED PAR-64 RGB Floor/Short.
SAFETY INSTRUCTIONS
CAUTION!
Be careful with your operations. With a dangerous voltage you can suffer a dangerous
electric shock when touching the wires!
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to
ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning
notes written in this user manual.
Important:
Damages caused by the disregard of this user manual are not subject to warranty. The dealer
will not accept liability for any resulting defects or problems.
If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it
on immediately. The arising condensation water might damage your device. Leave the device switched off
until it has reached room temperature.
00066216, Version 1.2 15/23
Please make sure that there are no obvious transport damages. Should you notice any damages on the A/C
connection cable or on the casing, do not take the device into operation and immediately consult your local
dealer.
This device falls under protection-class I. The power plug must only be plugged into a protection class I
outlet. The voltage and frequency must exactly be the same as stated on the device. Wrong voltages or
power outlets can lead to the destruction of the device and to mortal electrical shock.
Always plug in the power plug last. The power plug must always be inserted without force. Make sure that
the plug is tightly connected with the outlet.
Never let the power-cord come into contact with other cables! Handle the power-cord and all connections
with the mains with particular caution! Never touch them with wet hands, as this could lead to mortal
electrical shock.
Never modify, bend, strain mechanically, put pressure on, pull or heat up the power cord. Never operate next
to sources of heat or cold. Disregard can lead to power cord damages, fire or mortal electrical shock.
The cable insert or the female part in the device must never be strained. There must always be sufficient
cable to the device. Otherwise, the cable may be damaged which may lead to mortal damage.
Make sure that the power-cord is never crimped or damaged by sharp edges. Check the device and the
power-cord from time to time.
If extension cords are used, make sure that the core diameter is sufficient for the required power
consumption of the device. All warnings concerning the power cords are also valid for possible extension
cords.
Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the
power-cord by the plug. Never pull out the plug by tugging the power-cord. Otherwise, the cable or plug can
be damaged leading to mortal electrical shock. If the power plug or the power switch is not accessible, the
device must be disconnected via the mains.
If the power plug or the device is dusty, the device must be taken out of operation, disconnected and then be
cleaned with a dry cloth. Dust can reduce the insulation which may lead to mortal electrical shock. More
severe dirt in and at the device should only be removed by a specialist.
There must never enter any liquid into power outlets, extension cords or any holes in the housing of the
device. If you suppose that also a minimal amount of liquid may have entered the device, it must immediately
be disconnected. This is also valid, if the device was exposed to high humidity. Also if the device is still
running, the device must be checked by a specialist if the liquid has reduced any insulation. Reduced
insulation can cause mortal electrical shock.
There must never be any objects entering into the device. This is especially valid for metal parts. If any metal
parts like staples or coarse metal chips enter into the device, the device must be taken out of operation and
disconnected immediately. Malfunction or short-circuits caused by metal parts may cause mortal injuries.
During the initial start-up some smoke or smell may arise. This is a normal process and does not necessarily
mean that the device is defective.
HEALTH HAZARD!
Never look directly into the light source, as sensitive persons may suffer an
epileptic shock (especially meant for epileptics)!
Keep away children and amateurs!
Never leave this device running unattended.
00066216, Version 1.2 16/23
OPERATING DETERMINATIONS
This device is a lighting effect for creating decorative effects. This product is only allowed to be operated with
an alternating voltage of 230 V, 50 Hz and was designed for indoor use only.
This device is designed for professional use, e.g. on stages, in discotheques, theatres etc.
Lighting effects are not designed for permanent operation. Consistent operation breaks will ensure that the
device will serve you for a long time without defects.
Do not shake the device. Avoid brute force when installing or operating the device.
When choosing the installation-spot, please make sure that the device is not exposed to extreme heat,
moisture or dust. There should not be any cables lying around. You endanger your own and the safety of
others!
This device must never be operated or stockpiled in sourroundings where splash water, rain, moisture or fog
may harm the device. Moisture or very high humidity can reduce the insulation and lead to mortal electrical
shocks. When using smoke machines, make sure that the device is never exposed to the direct smoke jet
and is installed in a distance of 0.5 meters between smoke machine and device. The room must only be
saturated with an amount of smoke that the visibility will always be more than 10 meters.
The ambient temperature must always be between -5° C and +45° C. Keep away from direct insulation
(particularly in cars) and heaters.
The relative humidity must not exceed 50 % with an ambient temperature of 45° C.
This device must only be operated in an altitude between -20 and 2000 m over NN.
Never use the device during thunderstorms. Over voltage could destroy the device. Always disconnect the
device during thunderstorms.
The symbol
---m
determines the minimum distance from lighted objects. The minimum distance
between light-output and the illuminated surface must be more than 0.1 meters.
This device is only allowed for an installation via the mounting bracket. In order to safeguard sufficient
ventilation, leave 50 cm of free space around the device.
The housing must never touch surrounding surfaces or objects.
Make sure that the area below the installation place is blocked when rigging, derigging or servicing the
fixture.
Always fix the fixture with an appropriate safety bond.
The maximum ambient temperature Ta = 45° C must never be exceeded.
Operate the device only after having become familiarized with its functions. Do not permit operation by
persons not qualified for operating the device. Most damages are the result of unprofessional operation!
Never use solvents or aggressive detergents in order to clean the device! Rather use a soft and damp cloth.
Please use the original packaging if the device is to be transported. Make sure that you pack the device in
the original state.
Please consider that unauthorized modifications on the device are forbidden due to safety reasons!
Never remove the serial barcode from the device as this would make the guarantee void.
If this device will be operated in any way different to the one described in this manual, the product may suffer
damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-
circuit, burns, electric shock, crash etc.
00066216, Version 1.2 17/23
DESCRIPTION
Features
Professional spot as LED RGB DMX model!
Operable in stand-alone mode or via DMX • DMX512 control possible via any commercial DMX controller
(occupies 5 channels) • 3 or 5 DMX channels selectable for numerous applications • Sound-control via built-
in microphone • Comfortable addressing and setting via control panel with LED display and four operating
buttons • Functions: Static colors, RGB color blend, 6 internal programs, dimmer and strobe settings via
DMX, Master/Slave • Equipped with 183 10 mm LEDs • Beam angle approximately 10° • Locking possibility
at the mounting bracket • Ready for connection via power cord with safety-plug • Available as hanging spot
or as floor spot • Silver or black housing available.
INSTALLATION
The floor device can be installed on the ground or on the wall or ceiling.
Overhead rigging
DANGER TO LIFE!
Please consider the EN 60598-2-17and the respective national standards during the installation!
The installation must only be carried out by an authorized dealer!
The installation of the projector has to be built and constructed in a way that it can hold 10 times the weight
for 1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down
if the main attachment fails.
When rigging, derigging or servicing the fixture staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert before taking into operation for the first time and after changes before taking into operation another
time.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by a
skilled person once a year.
Procedure:
The projector should be installed outside areas where persons may walk by or be seated.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to)
calculating working load limits, installation material being used, and periodic safety inspection of all
installation material and the projector. If you lack these qualifications, do not attempt the installation yourself,
but instead use a professional structural rigger. Improper installation can result in bodily injury and.or
damage to property.
The projector has to be installed out of the reach of people.
If the projector shall be lowered from the ceiling or high joists, professional trussing systems have to be
used. The projector must never be fixed swinging freely in the room.
00066216, Version 1.2 18/23
Caution: Projectors may cause severe injuries when crashing down! If you have doubts concerning the
safety of a possible installation, do NOT install the projector!
Before rigging make sure that the installation area can hold a minimum point load of 10 times the projector's
weight.
DANGER OF FIRE!
When installing the device, make sure there is no highly-inflammable
material (decoration articles, etc.) within a distance of min. 0.5 m.
Mount the projector with the mounting-bracket to your trussing system using an appropriate clamp.
For overhead use, always install an appropriate safety bond.
You must only use safety bonds complying with DIN 56927, quick links complying with DIN 56926, shackles
complying with DIN EN 1677-1 and BGV C1 carbines. The safety bonds, quick links, shackles and the
carbines must be sufficiently dimensioned and used correctly in accordance with the latest industrial safety
regulations (e. g. BGV C1, BGI 810-3).
Please note: for overhead rigging in public or industrial areas, a series of safety instructions have to be
followed that this manual can only give in part. The operator must therefore inform himself on the current
safety instructions and consider them.
The manufacturer cannot be made liable for damages caused by incorrect installations or insufficient safety
precautions!
Pull the safety bond through the hole in the mounting-bracket and over the trussing system or a safe fixation
spot. Insert the end in the quick link and tighten the safety screw.
The maximum drop distance must never exceed 20 cm.
A safety bond which already held the strain of a crash or which is defective must not be used again.
Adjust the desired inclination-angle via the mounting-bracket and tighten the fixation screws.
DANGER TO LIFE!
Before taking into operation for the first time, the installation has to be approved by an expert!
DMX512 control
The wires must not come into contact with each other, otherwise
the devices will not work at all, or will not work properly.
Please note, the starting address depends upon which controller is being used.
Only use a DMX cable and 3-pin XLR plugs and connectors in order to connect the controller with the fixture
or one fixture with another.
00066216, Version 1.2 19/23
Occupation of the XLR connection:
If you are using controllers with this occupation, you can connect the DMX output of the controller directly
with the DMX input of the first device in the DMX chain. If you wish to connect DMX controllers with other
XLR outputs, you need to use adapter cables.
Building a serial DMX chain:
Connect the DMX output of the first device in the DMX chain with the DMX input of the next device. Always
connect one output with the input of the next device until all devices are connected.
Caution: At the last fixture, the DMX cable has to be terminated. Plug the terminator with a 120
resistor
between Signal (–) and Signal (+) in the DMX output of the last fixture.
Master/Slave-Operation
The master/slave-operation enables that several devices can be synchronized and controlled by one master-
device.
On the rear panel of the EUROLITE LED PAR-Spot you can find an XLR-jack and an XLR-plug, which can
be used for connecting several devices.
Choose the device which is to control the effects. This device then works as master-device and controls all
other slave-devices, which are to be connected to the master-device via a stereo shielded cable. Connect
the OUT-jack with the IN-plug of the next device.
Set the Master device to one of the stand alone modes ("C---" or "P---") and set each Slave device to the
same DMX address "d001".
Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable Pin International
Brown Live L
Blue Neutral N
Yellow/Green Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
00066216, Version 1.2 20/23
OPERATION
After you connected the spot to the mains, the EUROLITE LED PAR-64 RGB Floor/Short starts running.
The LED display lights up and you can choose the desired settings.
The device has two operating modes. It can be operated in Stand Alone mode via the display or it can be run
in DMX-controlled mode via a DMX controller.
- STAND ALONE-MODE
Setting Solid Colors
Internal Programs, Sound Control
- DMX MODE
STAND ALONE-MODE
In Stand Alone Mode, the LED PAR-64 RGB Floor/Short can be used without a controller.
Disconnect the LED PAR-64 RGB Floor/Short from the controller.
Setting Solid Colors
Press the MODE button to select the solid color mode. When the display shows C, you can select the
desired solid color via the UP or DOWN buttons (see following graphic).
Mode: Value: Function:
C
C01 Red
C02 Green
C03 Blue
C04 Cyan
C05 Purple
C06 Yellow
C07 White
Internal Programs, Sound Control
Press the MODE button to select the internal program mode. When the display shows P, you can select the
desired internal program, with or without sound control, via the UP or DOWN buttons (see following graphic).
Mode: Value: Function:
P
P1
Endless loop in 7 colors,
change every 3 seconds
P2
Endless loop in 7 colors,
fade every 3 seconds
P3
Endless loop in 3 colors,
change every 3 seconds
P4
Endless loop in 3 colors,
fade every 3 seconds
P5
Endless loop in 7 colors,
via sound control
P6
Endless loop in 3 colors,
via sound control
Setting the Sound Sensitivity:
You can do without a controller as the device features a built-in microphone, which provides automatic sound
control.
Manual adjustements via display as follows:
00066216, Version 1.2 21/23
Mode: Value: Sensitivity:
S
S00-S99 Decreasing sensitivity
You can select the desired sensitivity via the UP or DOWN buttons.
DMX MODE
The Control Board allows you to assign the DMX fixture address, which is defined as the first channel from
which the LED PAR-64 RGB Floor/Short will respond to the controller.
Addressing
Press the MODE button until the display shows ADD. You can now set the desired address via the UP or
DOWN buttons.
Setting the DMX Start Address:
Mode: Value:
ADD
001 - 512
Controlling:
After having addressed the LED PAR-64 RGB Floor/Short, you may now start operating it via your lighting
controller.
Note:
The modes of DMX 512 data are shown via the DMX indicator.
After switching on, the device will automatically detect whether DMX 512 data is received or not. If the data
is received, a point will blink in the first position on the display.
If there is no data received at the DMX-input, the point will not blink.
This situation can occur if:
- the 3 PIN XLR plug (cable with DMX signal from controller) is not connected with the input of the device.
- the controller is switched off or defective,
- the cable or connector is defective or the signal wires are not properly connected with the input connector.
Note:
It’s necessary to insert the XLR termination plug with 120
 in the last lighting in the link in order to ensure
proper transmission on the DMX data link.
Choosing a DMX Channel Mode with 3 or 5 Channal Occupation
The device has 2 DMX-modes. The Control Board allows you to assign the DMX-Mode.
Setting DMX Mode
After setting the desired address via the UP or DOWN buttons, press the MODE button again and the
display shows CHND.
You can now set the desired DMX Channel Mode via the UP or DOWN buttons.
Mode: Value:
CHND
5ch (default setting)
3ch
00066216, Version 1.2 22/23
DMX-protocol
5 Channel Mode
Channel: Value: Function:
CH1 000 – 255 Red (0 – 100%)
Channel: Value: Function:
CH2 000 – 255 Green (0 – 100%)
Channel: Value: Function:
CH3 000 – 255 Blue (0 – 100%)
Channel: Value: Function:
CH4 000 – 255 Dimmer (0 – 100%)
Channel: Value: Function:
CH5
000 – 000 ON
001 – 005 Sound Control (7 colors)
006 – 010 ON
011 – 255 Strobe (increasing)
3 Channel Mode
Channel: Value: Function:
CH1 000 – 255 Red (0 – 100%)
Channel: Value: Function:
CH2 000 – 255 Green (0 – 100%)
Channel: Value: Function:
CH3 000 – 255 Blue (0 – 100%)
CLEANING AND MAINTENANCE
Disconnect from mains before starting maintenance operation!
DANGER TO LIFE!
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
There are no serviceable parts inside the device except for the fuse. Maintenance and service operations are
only to be carried out by authorized dealers.
Replacing the fuse
If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Unscrew the fuseholder with a fitting screwdriver from the housing (anti-clockwise).
Step 2: Remove the old fuse from the fuseholder.
Step 3: Install the new fuse in the fuseholder.
Step 4: Replace the fuseholder in the housing and fix it.
00066216, Version 1.2 23/23
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by authorized dealers only
in order to avoid hazards.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Power supply: 230 V AC, 50 Hz ~
Power consumption: 20 W/50 VA
Number of channels: 3/5
DMX512 connection: 3-pin XLR
Sound-control: via built-in microphone
Maximum ambient temperature T
a
:
45° C
Maximum housing temperature T
C
:
65° C
Min. distance from flammable surfaces: 0.5 m
Min. distance to lighted object: 0.1 m
Fuse: F 1 A, 250V
LED type: 10 mm
Number of LEDs: 182
Beam angle: 10°
Dimensions (LxWxH): 280 x 265 x 320 mm
Weight: 1.5 kg
Accessories: No.
EUROLITE TH-50 Theatre hook, silver 58000650
EUROLITE TH-50S Theatre hook, black 58000651
Safety bond A 3x600mm up to 5kg, silver 58010310
EUROLITE DMX LED Operator 1 70064501
EUROLITE DMX LED Operator 4 70064504
Please note: Every information is subject to change without prior notice. 13.08.2012 ©
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23

EuroLite PAR-64 Profi Spot User manual

Category
Stroboscopes & disco lights
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages