Marmitek SD833 User manual

Category
Smoke detectors
Type
User manual
P
ROGUAR
D
800
20188 / 20070314 • SD833
TM
© ALL RIGHTS RESERVED MARMITEK ®
USER MANUAL 2
GEBRAUCHSANLEITUNG 8
GUIDE UTILISATEUR 15
MODO DE EMPLEO 21
MANUALE D’ISTRUZIONI 27
GEBRUIKSAANWIJZING 33
PROGUARD800
SERIES
SD833 SMOKE DETECTOR
SD833 2
SAFETY WARNINGS
• The SD833 smoke detector is designed specifically for localised home use. If
smoke is detected, the appliance will sound a piercing alarm. Make sure the smoke
detector is installed in such a way that the built-in siren will be heard by residents
even when they are asleep. If necessary, install several smoke detectors. For
additional functionality, you can also use the smoke detector in combination with
Marmitek ProGuard800 security system. Attention: the operation of this additional
function is not included in the manufacturer's liability.
• This product is not a toy. Keep out of reach of children.
• Check the detector every week to make sure it is in proper working order.
• To prevent short circuits, this product should only be used inside and only in dry
spaces. Do not expose the components to rain or moisture. Do not use the product
close to a bath, swimming pool etc.
• Do not expose the components of your systems to extremely high temperatures
or bright light sources.
• The product should only be repaired or serviced by a qualified repairman.
• In case of improper usage or if you have, altered and repaired the product
yourself, all guarantees expire. Marmitek does not accept responsibility in the case
of improper usage of the product or when the product is used for purposes other
than specified. Marmitek does not accept responsibility for additional damage other
than covered by the legal product responsibility.
• Keep batteries out of the reach of children. Dispose of batteries as chemical
waste. Never use old and new batteries or different types of batteries together.
Remove the batteries when you are not using the system for a longer period of
time. Check the polarity (+/-) of the batteries when inserting them in the product.
Wrong positioning can cause an explosion.
INTRODUCTION
The SD833 is a brand-name smoke detector with an integrated Marmitek
transmitter. The SD833 Smoke Detector is for use with the Marmitek ProGuard800
systems. When you wish to know more about the complete system, its possibilities
and its settings, then you can check out the installation manual or visit
www.marmitek.com
.
1. GENERAL INFORMATION AND FUNCTION
The smoke detector can detect incipient low temperature fires and open fires with
smoke development. The smoke detector operates by the optical principle. There
are no radioactive substances in this detector.
The smoke detector incorporates the following features:
• It monitors rooms for the development of smoke.
• It has an integrated signal transmitter to trigger a Marmitek ProGuard800 Security
system.
3 © MARMITEK
2. APPLICATION
The radio smoke detector is intended for the detection of smoke in interiors by the
use of optical and acoustic warnings, as well as wireless transmission over
distances of up to 30 meters. Range may vary due to battery and temperature
conditions. The SD833 smoke detector does not sense gas, heat or smokeless
flames! The equipment may not be modified under any circumstances.
3. POSITIONING
It is advisable to install several smoke detectors in your home. At least one smoke
detector should be installed on each floor. This ensures that an effective warning is
possible when a fire starts. One smoke detector must be installed in the area
outside the bedroom which is used as the exit (corridor and/or staircase). Also
ensure that you install the smoke detector at a location where it can be easily
heard, even through the closed door of the bedroom! (Otherwise you will not wake
up during a fire alarm!). Recommended best and acceptable locations to mount
smoke detectors (figure A):
The smoke detector should be installed on the ceiling in the centre of the room.
Smoke rises and gathers in this area (figure B) and placing the smoke alarm here
guarantees the earliest possible alarm warning. For sloping roofs, the smoke alarm
should be installed about 1 meter from the highest point, as displayed in figure C.
Smoke detectors can be installed in all rooms, but not in the bathroom or directly
above the cooking area in the kitchen. To avoid false alarms, do not install the
SD833 smoke detector in your kitchen, garage, in dusty places, in places with a
higher than average air flow (near ventilation, open windows), near metal and in
places where the temperature is below 5°C or above 37°C. Ensure that the smoke
detector is not installed directly on or near large metal objects as they can affect
the radio range. Before installing the SD833 smoke detector on your ceiling or the
wall, ensure that the SD833 is within range of your Marmitek security system. You
can test this by pushing the test button of the SD833. The Marmitek security
system should now be triggered, depending on the settings. In the case of range
problems, choose a different location for your SD833 smoke detector. Moving the
SD833 just a few centimetres can make a big difference in range.
4. INSTALLATION
The following procedure explains the installation of the SD833 wireless smoke
detector and its registration to the receiver.
To install smoke detectors:
SD833 4
1. Open the cover by lifting the opening tab while firmly holding the base with
your other hand.
2. Install a 9V battery into the detector’s battery snap. See 5.b Placing the
battery
3. Insert the Test jumper; the SD833 enters Test mode and the LED flashes
every few seconds.
4. From the Programming menu, select Devices, Zones [911].
5. Select the zone to which you want to register the transmitter; the system
initiates Registration mode. When Save? appears on the panel’s LCD
display, press 9.
6. After registration, remove the Test jumper and place it over one pin for
storage.
5. MOUNTING
a. Attaching to Ceiling or Wall.
The Smoke Detector is battery operated and needs only wiring, if the Inter-connect
facility is being used.
1. Before permanently mounting the unit, test the transmitter from the exact
mounting position.
2. Pull cover open at tab.
3. Place the base on ceiling or wall exactly where you want to mount the unit.
With a pencil, mark the location of the screw holes.
OPEN TAB
BATTERY
INSTALLATION
DATE
SCREW HOLE
TEST
BUTTON
SCREW HOLE
CHAMBER LABEL BATTERY
PUSH BACK TO EASE
BATTERY REMOVAL
Figure 1
TEST JUMPER
5 © MARMITEK
4. Taking care to avoid any electrical wiring in the ceiling or wall, drill a hole
through the centres of the marked locations. Push the plastic screw anchors
provided into the drilled holes. Screw in firmly.
5. Close the cover until it snaps together with the base.
b. Placing the battery
The battery is easily removed from the holder by holding back one of the plastic
clips while lifting the battery with the other hand.
1. Snap Battery Connectors to Battery. They fit together only one way.
2. Gently push battery into battery holder.
3. With a pencil, write the date of battery installation on the inside of the
cover to remind you when to replace the battery.
4. To close the cover match up snap-in hinges and gently press together
until base and cover snap together. Test the installed Smoke Detector –
see 6b Manually testing your Smoke Detector.
NOTE: You may hear a loud chirp when attaching the Battery Connectors to the
Battery.
c. Battery Missing indicator
This Smoke detector fitted with a warning flag which pops up when the battery is
removed. This prevents the cover from closing when there is no battery in the unit.
When the battery is being installed or changed, this flag must be held down while
gently pushing the Battery into the Battery Holder.
6. LOOKING AFTER YOUR SMOKE DETECTOR
a. Automatic Self-Test
The smoke chamber automatically tests itself every 40 seconds. If the chamber is
degraded it will beep without
the LED flashing at the same time. If this happens
clean the unit. If the beeping persists and the beep does not coincide with an LED
flash, return the unit to service.
b. Manually testing your Smoke Detector
It is recommended that you test your Smoke Detector at least once a week to be
sure the unit is working. It will also help you and your family to become familiar with
the sound of the alarm.
When you press the Test Button it simulates the effect of smoke during a real fire.
So, there is no need to test the Alarm with smoke.
Press and hold the Test button until the Alarm sounds (it may take up to 10
seconds). The alarm will stop sounding shortly after the Button is released. If the
alarm fails to sound, follow this checklist.
SD833 6
Figure 2
1. Check Battery Connectors to be sure they are firmly snapped to the
Battery.
2. Replace the Battery.
3. Check for any sign of contamination such as cobwebs or dust and clean
the alarm as described in d) Cleaning your Smoke Detector if necessary.
WARNING: Do not test with flame. This can set fire to the alarm and damage the
house. We do not recommend testing with smoke as the results can be misleading
unless special device is used.
c. Replacing the battery
A fresh battery should last about one year. When battery power is low and
replacement is necessary, the alarm will “beep” and the LED will flash at the same
time about once per minute for at least 30 days. For maximum reliability, replace
battery at least once a year.
Test the alarm for correct operation using the test button whenever the battery is
replaced.
If the power indicator light ceases flashing, replace the battery. Be sure to replace
the battery as soon as possible to ensure proper operation and to avoid a leaking
battery. Leakage could cause damage to the alarm, furniture and carpeting.
WARNING: Use of any other battery than specified in the technical data may be
detrimental to the operation of the Smoke Detector
d. Cleaning your Smoke Detector
Clean your smoke detector regularly. Use a soft bristle brush or the brush
attachment of your vacuum cleaner to remove dust from the sides and cover slots
where the smoke enters. Keep cover closed while cleaning. Do not vacuum or
brush inside the Smoke Detector. To clean the cover, remove it completely and use
only mild soap and water. Dry cover thoroughly before replacing it.
WARNING: Do not paint your smoke detector.
Other than the maintenance and cleaning described in this leaflet, no other
customer servicing of the product is required. Repairs, when needed, must be
performed only by the manufacturer.
7. INTERCONNECTING YOUR SMOKE
DETECTORS
A maximum of 12 SD833 Smoke Detectors may be
wired together such that when one unit senses
smoke all other units sound a warning. This helps
ensure smoke alarms will be heard. Do not connect
to any other device as it may damage the unit or
affect performance.
7 © MARMITEK
A maximum of 1,500 meters (5,000 feet) of 18 AWG (0.82mm) wire can be used,
(maximum resistance between detectors 50 Ohm). The units are interconnected by
wiring all the terminals marked 1 together, and all the terminals marked 2 together
(as in figure 2 before screwing to ceiling). Draught from wiring openings, conduit, or
mounting boxes/holes, may blow smoke away from the sending chamber, making it
insensitive. It is essential that all such openings be closed by silicone sealant or
similar.
After wiring together the interconnect smoke detectors, test the first unit by
pressing the test button. All the detectors should alarm and the test button on the
first unit will flash about once a second. Check all the other units similarly.
8. TECHNICAL DATA
Antenna: Built-in Internal Whip
Frequency: 868.35MHz FM
Current Consumption: 30mA (transmission), 20μA (standby)
Power: 9V Alkaline Battery
RFI Immunity: 40V/m
Ambient temperature: 0° C to + 60° C (operation)
Dimensions: 138 x 118 x 44mm
Specifications may be modified without prior notice.
Environmental Information for Customers in the European Union
European Directive 2002/96/EC requires that the equipment bearing this symbol
on the product and/or its packaging must not be disposed of with unsorted
municipal waste. The symbol indicates that this product should be disposed of
separately from regular household waste streams. It is your responsibility to
dispose of this and other electric and electronic equipment via designated
collection facilities appointed by the government or local authorities. Correct disposal and
recycling will help prevent potential negative consequences to the environment and human
health. For more detailed information about the disposal of your old equipment, please contact
your local authorities, waste disposal service, or the shop where you purchased the product.
41 © MARMITEK
Copyrights
Marmitek is a trademark of Marmidenko B.V.  SD833 is a trademark of
Marmitek B.V. All rights reserved.
Copyright and all other proprietary rights in the content (including but not
limited to model numbers, software, audio, video, text and photographs) rests
with Marmitek B.V. Any use of the Content, but without limitation, distribution,
reproduction, modification, display or transmission without the prior written
consent of Marmitek is strictly prohibited. All copyright and other proprietary
notices shall be retained on all reproductions.
Con ciò, Marmitek BV, dichiara che il SD833 è conforme ai requisiti essenziali ed altre
disposizioni relative alla Direttiva :
Direttiva 1999/5/CE del Parlamento europeo e del Consiglio, del 9 marzo 1999,
riguardante le apparecchiature radio e le apparecchiature terminali di
telecomunicazione e il reciproco riconoscimento della loro conformità
Direttiva 89/336/CEE del Consiglio del 3 maggio 1989 per il ravvicinamento delle
legislazioni degli Stati Membri relative alla compatibilità elettromagnetica
Bij deze verklaart Marmitek BV, dat deze SD833 voldoet aan de essentiële eisen en aan
de
overige relevante bepalingen van Richtlijnen:
Richtlijn 1999/5/EG van het Europees Parlement en de Raad van 9 maart 1999
betreffende radioapparatuur en telecommunicatie-eindapparatuur en de wederzijdse
erkenning van hun conformiteit
Richtlijn 89/336/EEG van de Raad van 3 mei 1989 betreffende de onderlinge
aanpassing van de wetgevingen van de Lid-Staten inzake elektromagnetische
compatibiliteit
MARMITEK BV - P.O. BOX 4257 - 5604 EG EINDHOVEN – NETHERLANDS
868.35MHz is not intended for use in BG, GR, PL & SI.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Marmitek SD833 User manual

Category
Smoke detectors
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI