Lochinvar 100133610, 100133601, 401-751, Water Pump 401-751 User manual

  • Hello! I am an AI chatbot trained to assist you with the Lochinvar 100133610 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
PUMP-Rec-07 Rev B
PUMP
Recommendation
PUMP RECOMMENDATION FOR
COPPER-FIN II 401-751 WATER HEATER
Pump Specifications
Part No. HorsePower Flanges Valute Material Flange Material Vendor Vendor Product Series Orientation
ARM3044PAB 1/4 2" Bronze Bronze Armstrong LS45 Horizontal
Installation Specifications
Recommended for Based on
Pump Model Numbers Maximum GPM Installation Type
Copper-Fin II Wtr Htr, CF(N,L) 401-751 55 GPM Single Water Heater piped to Single Storage Tank
ARM3044PAB Based on Based on
Minimum Pipe Diameter Connecting piping
2" Maximum 45 feet straight pipe with 6-Elbows, 2-Unions,2-Ball Valves and 1-Cold Water Inlet Tee
IMPORTANT: Read the Copper-fin II 399-2070 Installation and Operation Manual. If the planned system exceeds
the pump capacity in flow and/or head see “Pump Curves-All Pumps” for alternate pumps and pump curves.
OIL PORT
A
C
12-1/2”
15-3/4”
0
10
20
30 40 50 60
70
5
10
15
20
80
90
100
110
LS-45
TOTAL HEAD IN FEET
CAPACITY IN U.S. GALLONS PER MINUTE
B D
10”
1
PUMP-Rec-07 Rev B
PUMP
Recommendation
PUMP RECOMMENDATION FOR
COPPER-FIN II 0991-2071 WATER HEATER
Pump Specifications
Part No. HorsePower Flanges Valute Material Flange Material Vendor Vendor Product Series Orientation
ARM3024PAB 1/2 2-1/2" Bronze Bronze Armstrong 2B1050 Horizontal
Installation Specifications
Recommended for Based on
Pump Model Numbers Maximum GPM Installation Type
Copper-Fin II Wtr Htr, CF(N,L) 0991-2071 90 GPM Single Water Heater piped to Single Storage Tank
ARM3024PAB Based on Based on
Minimum Pipe Diameter Connecting piping
2-1/2" Maximum 45 feet straight pipe with 6-Elbows, 2-Unions,2-Ball Valves and 1-Cold Water Inlet Tee
IMPORTANT: Read the Copper-fin II 399-2070 Installation and Operation Manual. If the planned system exceeds
the pump capacity in flow and/or head see “Pump Curves-All Pumps” for alternate pumps and pump curves.
OIL PORT
A
C
16”
19-1/2”
B D
11-1/2”
2
/