  • Hello! I am an AI chatbot trained to assist you with the Whirlpool AKM 534/NB/01 Program Chart. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
AKM 534 PRODUCT DESCRIPTION SHEET
FR
5019 319 53061
1. Removable panstand grids
2. Medium burner
3. Rapid electric hotplate
4. Large burner
5. Small burner
6. Medium burner control knob
7. Large burner control knob
8. Small burner control knob
9. Hotplate control knob
10. Electric hotplate operation lamp
Symbols
Operation of burners with safety
device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti-
clockwise to the large flame and star
setting .
At the same time, keep the knob pressed
against the control panel until the burner
ignites.
After the burner has ignited, keep the knob
pressed for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations
described above.
Note:
Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
The safety device of the burner shuts off the
gas supply to the burner if its flame goes out
accidentally (because of a sudden gust of
wind, an interruption in the gas delivery, the
overflowing of liquids, etc.).
Operation of the electric hotplate
Set the knob to one of positions 1-6, which
correspond to different temperatures.
To switch off the hotplate, set the knob to
position "0".
44
1
4
5
3
2
10
9 6
7
8
Shaded circle Tap closed
Large flame
and star
Maximum opening/delivery
and electric ignition
Small flame Minimum opening or
reduced delivery
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions for
the correct distance.
Important:
If the cooktop is installed over a built-in oven
without forced ventilation cooling, make sure there
are air inlets and outlets to allow adequate
aeration inside the cabinet. Figure A illustrates an
assembly example.
INJECTORS TABLE CATEGORY II2E+3+
ELECTRIC HOT PLATE POWER: 1500 W.
FIG. A
Type of gas used Type of
burner
Injector
marking
Rated heat
capacity
Pcs-kW
Rated
consumption
Reduced
heat
capacity
Pcs-kW
Gas pressure
min. rat. max.
NATURAL GAS
(Methane) G 20
large
medium
small
128
94
76
3.00
1.65
1.00
286 l/h
157 l/h
95 l/h
0.60
0.35
0.30
17 20 25
NATURAL GAS
(Groningue) G 25
large
medium
small
128
94
76
2.78
1.53
0.93
308 l/h
170 l/h
103 l/h
0.60
0.35
0.30
20 25 30
LIQUID PETROLEUM
GAS
(Cylinder) G 30
large
medium
small
85
65
50
3.00
1.65
1.00
218 g/h
120 g/h
73 g/h
0.60
0.35
0.30
20 28-30 35
LIQUID PETROLEUM
GAS
(Cylinder) G 31
large
medium
small
85
65
50
3.00
1.65
1.00
214 g/h
118 g/h
71 g/h
0.60
0.35
0.30
25 37 45
Type of gas used Appliance model Total rated heat
capacity Pcs-kW
Total rated
consumption
Air required for
burning m3/h
G 20 20 mbar 3 gas + 1 E 5.65 538 l/h 11.3
G 25 25 mbar 3 gas + 1 E 5.24 581 l/h 10.5
G 30 28-30 mbar 3 gas + 1 E 5.65 411 g/h 11.3
G 31 37 mbar 3 gas + 1 E 5.65 403 g/h 11.3
/