Comet T4511 Quick start guide

Type
Quick start guide

This manual is also suitable for

Specifications are subject to change without notice. IE-SNC-N-Tx5xx-05
Transmitters and transducers Web Sensor Tx5xx
with Ethernet connection
PRODUCT DESCRIPTION
Transmitters and transducers Web Sensor Tx5xx with Ethernet connection are designed to measure temperature, relative humidity
and barometric pressure of air in non-aggressive environment. Transmitters and transducers are available in wall-mount version or with
probe on a cable. For measuring temperature and relative humidity of compressed air is used type TxxxxP.
Relative humidity transmitters allows to determine other calculated humidity variables like dew point temperature, absolute humidity,
specific humidity, mixing ratio and specific enthalpy.
Measured and calculated values are displayed on a two-line LCD display or can be read and then processed via Ethernet interface. The
following formats of Ethernet communication are supported: www pages with user-design possibility, Modbus TCP protocol, SNMPv1
protocol, SOAP protocol and XML. The instrument may send also a warning message if the measured value exceeds adjusted limit. The
messages can be sent up to 3 e-mail addresses or to Syslog server and can be sent by SNMP Trap too. The alarm states are also
displayed on the websites. The device setup can be made by the TSensor software (see www.cometsystem.com) or using the www
interface.
device type * measured values construction mounting
T0510 T ambient air wall
T4511 T external probe Pt1000/3850 ppm wall
T2514 P ambient air wall
T3510 T + RH + CV ambient air wall
T3511 T + RH + CV probe with a cable wall
T3511P T + RH + CV probe with a cable pressure up to 25 bars wall
T7510 T + RH + P + CV ambient air wall
T7511 T + RH + P + CV probe with a cable wall
f
* models marked TxxxxZ are custom - specified devices T…temperature, RH…relative humidity, P…barometric pressure, CV…computed values
INSTALATION AND OPERATION
The transmitters and transducers designed for mounting on the wall are mounted on a flat surface with two screws or bolts. The probe
with a cable probe is placed into a measured environment. Pay attention to the location of the device and probe. Incorrect choice of working
position could adversely affect accuracy and long-term stability of measured value.
The terminal for external probe Pt1000 connection is accessible after unscrewing four screws in the corners of case and removing the lid.
The Probe Pt1000 is connected by shielded cable with a length up to 10 m. The external probe cable shielding is connected to proper
terminal of the device only and cable should be located as far as possible from potential interference sources.
Devices don´t require special operation and maintenance. We recommend you periodic calibration for measurement accuracy validation.
DEVICE SETUP
For network device connection it is necessary to know new suitable IP address. The device can obtain this address automatically from a
DHCP server or you can use the static IP address, which you can get from your network administrator. Install the latest version of TSensor
software to your PC and according to the “Device connection procedure” (see next page) you connect the Ethernet cable and power supply
adapter. Then you run TSensor program, set the new IP address, configure the device in accordance with your requirements and finally
store the settings. The device setup can be made by the web interface too (see manual for devices at www.cometsystem.com). The default
IP address of each device is preset to 192.168.1.213.
ERROR STATES
Device continuously checks its state during operation and if an error appears, it is displayed relevant code: Err 1 measured or calculated
value is over the upper limit, Err 2 measured or calculated value is below the lower limit or pressure measurement error occurred, Err
0, Err 3 and Err 4 it is a serious error, please contact distributor of the device.
SAFETY INSTRUCTIONS
- Humidity and temperature sensors of the transmitters cannot be operate and store without a filter cap.
- Temperature and humidity sensors have not to be exposed to direct contact with water and other liquids.
- It is not recommended to use the humidity transmitters for long time under condensation conditions.
- Take care when unscrewing the filter cap as the sensor element could be damaged.
- Use only the power adapter according to technical specifications and approved according to relevant standards.
- Don’t connect or disconnect transmitters and transducers while power supply voltage is on.
- Before removing the T3511P probe make sure, that pressure in a measured area and ambient pressure are equal.
- Installation, electrical connection and commissioning should be performed by qualified personnel only.
- Devices contain electronic components, it needs to liquidate them according to currently valid conditions.
- To supplement the information provided in this data sheet, use the manuals and other documentations which are
available at www.cometsystem.com