LG S36AWN-ND0 Owner's manual

Type
Owner's manual

This manual is also suitable for

Room Air Conditioner
SVC MANUAL(Exploded View)
MODEL : AUUW366D ( S36AWN )
ASNW36GDGM0 (S36AWN )
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.
http://biz.lgservice.com
2 Room Air Conditioner
1. Specification
Cooling Capacity kW
(Min~Rating~Max) Btu/h.
Heating Capacity kW
(Min~Rating~Max) Btu/h.
Power Input Cooling/Heating W
Running Current Cooling/Heating A
Starting Current Cooling/Heating A
EER W/W
Btu/h.W
COP W/W
Power Supply Ø / V / Hz
Power Factor %
Air Flow Rate Indoor,Max m
3
/min(CFM)
Outdoor,Max m
3
/min(CFM)
Moisture Removal l/h.
Sound Level Indoor,H/M/L dB(A)±3
Outdoor,Max dB(A)±3
Refrigerant & Charge(at 7.5 m) g(oz)
Additional Refrigerant charge g/m(oz/ft)
Compressor Type
Model
Motor Type
Oil Type
Oil Charge cc
O.L.P. name
Fan(Indoor) Type
Motor Output W
Fan(Outdoor) Type
Motor Type
Motor Output W
Circuit Breaker* A
Power Supply Cable No.*mm
2
Power and Transmission Cable No.*mm
2
+No.*mm
2
Piping Liquid Side mm(in)
Connections Gas Side mm(in)
Drain Hose O.D., I.D. mm(in)
Dimensions Indoor (W*H*D) mm
inch
Outdoor (W*H*D) mm
inch
Net Weight Indoor kg(lbs)
Outdoor kg(lbs)
Operation Range Cooling(Outdoor) °C(°F)
Heating(Outdoor) °C(°F)
Max. Piping Length m(ft)
Max. Elevation Difference m(ft)
Tool Code(Chassis) Indoor + Outdoor
Models
ASNW36GDGM0
AUUW366D
9
30709
10.4
35486
2,990/3,540
13.6/16.5
13.6/16.5
3.01
10.27
2.94
1 / 220 ~ 240 / 50
97
21(742)
58(2048)
3.5
48 /44/ 39
58
R410A, 2,200(77.6)
35(0.376)
Rotary
5JD420XAD22
Brushless DC motor
FV50S
1300
CS-7L 115
Cross Flow Fan
70
Propeller
Brushless DC motor
100
25
3*2.5
4*0.75
6.35(1/4)
15.88(5/8)
21.5, 16 (0.85, 0.63)
1,209*346*205
47.6*13.6*8.1
870*1060*320
34.3*41.7*12.6
19(41.9)
75(165.3)
-10 ~ 43 (14 ~ 109.4)
-15 ~ 24 (5 ~ 75.2)
50(164)
30(98.4)
SD + UE2
Note:
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27°C(80.6°F) DB/19°C(66.2°F) WB
- Outdoor Temperature 35°C(95°F) DB/24°C(75.2°F) WB
Heating: - Indoor Temperature 20°C(68°F) DB/15°C(59°F) WB
- Outdoor Temperature 7°C(44.6°F) DB/6°C(42.8°F) WB
Piping Length - Interconnecting Piping Length 7.5m
- Level Difference of Zero
2. Wiring cable size must comply with the applicable local and national
code.
3. The specification may be subject to change without notic for purpose
of improvement.
Service Manual 3
2. Function Table
Note :
• O: Applied, • X: Not applied, • - : No relation,
• Option: Model name & price are different according to options, and assembled in factory with main unit.
• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package.
Air flow Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Air purifying Deodorizing filter
Plasma air purifier
Prefilter(washable / anti-fungus)
Installation Drain pump
E.S.P. control
Electric heater(operation)
High ceiling operation
Reliability Hot start
Self diagnosis
Soft dry operation
Convenience Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Individual Standard wired remote controller
control Deluxe wired remote controller
Simple wired remote controller
Wired remote controller(for hotel use)
Wireless remote controller(simple)
Wireless LCD remote control
CAC network General central controller (Non LGAP)
function Dry contact
Network Soluation(LGAP)
PDI(power distribution indicator)
PI 485
Special Zone control
function kit CTIE
Electro thermostat
Others Thermistor
FunctionCategory
ASNW36GDGM0
1
Auto
Auto
O
O
4/5/4
O
O
O
X
O
O
O
X
-
-
X
O
O
O
O
O
O
O
X
O
X
O
O
X
X
X
X
X
X
AHWRHD
X
X
X
X
X
X
X
X
X
X
Indoor Unit
4 Room Air Conditioner
Note :
• O: Applied, • X: Not applied, • - : No relation,
• Option: Model name & price are different according to options, and assembled in factory with main unit.
• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package.
Defrost / Deicing
High pressure switch
Low pressure switch
Reliability
Phase protection
Restart delay (3-minutes)
Self diagnosis
Soft start
Test function
Convenience
Auto operation(Artificial intelligence)
Auto restart operation
CAC network
Network soluation(LGAP)
function
PDI(Power Distribution Indicator)
PI485
Special
Low ambient operation
function kit
Others Thermistor
FunctionCategory
AUUW366D
O
O
X
X
O
O
O
O
O
O
X
X
X
O(Program Logic)
-
Outdoor Unit
2. Function Table
Service Manual 5
3. Piping Diagrams
High
Pressure
S/W
Th7
Inverter
Compressor
Reversing
Valve
Th6
Indoor Unit Outdoor Unit
Heat
Exchanger
(Evaporator)
Heat
Exchanger
E.E.V
Accumulator
Accumulator
Gas Side
3-Way Valve
3-Way Valve
Liquid Side
Cooling
Heating
Th1
Th3
Th2
Th4
Th5
LOC. Description PCB Connector
Th1 Thermister for indoor air temperature
CN_TH1(INDOOR)
Th2 Thermister for indoor pipe(in) temperature
Th3 Thermister for indoor pipe(out) temperature CN-TH2(INDOOR)
Th4 Thermister for outdoor pipe temperature
CN_TH2(OUTDOOR)
Th5 Thermister for outdoor air temperature
Th6 Thermister for outdoor discharge pipe temperature(Inverter)
CN_TH3(OUTDOOR)
Th7 Thermister for outdoor suction pipe temperature(Inverter)
6 Room Air Conditioner
4. Wiring Diagrams
CN-MOTOR1 CN-L/R(BL)
CN-TH1
CN-DISP1(WH)
CN-DISP2(BL)
CN-HVB
CN-U/D(WH)
CN-12V
CN-TH2
Indoor Unit
Service Manual 7
CN-PFC-IN
CN-PFC-OUT
CN_TH3
CN-TH2
CN-MOTOR1
CN-MOTOR2
CN 4WAY
CN_H/P
CN_LEV1
CN_COM
Outdoor Unit
4. Wiring Diagrams
- 8 - Room Air Conditioner
Indoor Unit
5. Exploded View
152302
159830
342800
359011
131410
135511
733010
249951
135311
147581-1
147581-2
135516
268711-1
146811-2
W6640
346810
266090
567480-3
268711-3
267110
135314
149304
152313
135316
146811-1
567480-1
35211B
354210-2
352150
354210-1
Part for
Plasma Model
Upper
Lower
Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request.
Please check the correct parts in View RPL(Replacement Part List) on GCSC.
(GCSC Website http://biz.Lgservice.com,)
Service Manual - 9 -
Outdoor Unit
546810-1
546810-2
559010
554160
554031
447910
430410
435512
435301
437210
437211
349480
349480
SERVICE
MANUAL
INS
TALL MANUAL
OWNERS MANUAL
137213-2137213-1
435300
552117
552114
552116
435511
549610
552203-1
552203-2
547890
567480-5
567480-4
661400
W49810
552115
552111
649950
268711-6
561410
Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request.
Please check the correct parts in View RPL(Replacement Part List) on GCSC.
(GCSC Website http://biz.Lgservice.com,)
5. Exploded View
P/NO : MFL37468308
AUGUST, 2007
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

LG S36AWN-ND0 Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI