2 Room Air Conditioner
1. Specification
Cooling Capacity kW
(Min~Rating~Max) Btu/h.
Heating Capacity kW
(Min~Rating~Max) Btu/h.
Power Input Cooling/Heating W
Running Current Cooling/Heating A
Starting Current Cooling/Heating A
EER W/W
Btu/h.W
COP W/W
Power Supply Ø / V / Hz
Power Factor %
Air Flow Rate Indoor,Max m
3
/min(CFM)
Outdoor,Max m
3
/min(CFM)
Moisture Removal l/h.
Sound Level Indoor,H/M/L dB(A)±3
Outdoor,Max dB(A)±3
Refrigerant & Charge(at 7.5 m) g(oz)
Additional Refrigerant charge g/m(oz/ft)
Compressor Type
Model
Motor Type
Oil Type
Oil Charge cc
O.L.P. name
Fan(Indoor) Type
Motor Output W
Fan(Outdoor) Type
Motor Type
Motor Output W
Circuit Breaker* A
Power Supply Cable No.*mm
2
Power and Transmission Cable No.*mm
2
+No.*mm
2
Piping Liquid Side mm(in)
Connections Gas Side mm(in)
Drain Hose O.D., I.D. mm(in)
Dimensions Indoor (W*H*D) mm
inch
Outdoor (W*H*D) mm
inch
Net Weight Indoor kg(lbs)
Outdoor kg(lbs)
Operation Range Cooling(Outdoor) °C(°F)
Heating(Outdoor) °C(°F)
Max. Piping Length m(ft)
Max. Elevation Difference m(ft)
Tool Code(Chassis) Indoor + Outdoor
Models
ASNW36GDGM0
AUUW366D
9
30709
10.4
35486
2,990/3,540
13.6/16.5
13.6/16.5
3.01
10.27
2.94
1 / 220 ~ 240 / 50
97
21(742)
58(2048)
3.5
48 /44/ 39
58
R410A, 2,200(77.6)
35(0.376)
Rotary
5JD420XAD22
Brushless DC motor
FV50S
1300
CS-7L 115
Cross Flow Fan
70
Propeller
Brushless DC motor
100
25
3*2.5
4*0.75
6.35(1/4)
15.88(5/8)
21.5, 16 (0.85, 0.63)
1,209*346*205
47.6*13.6*8.1
870*1060*320
34.3*41.7*12.6
19(41.9)
75(165.3)
-10 ~ 43 (14 ~ 109.4)
-15 ~ 24 (5 ~ 75.2)
50(164)
30(98.4)
SD + UE2
Note:
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27°C(80.6°F) DB/19°C(66.2°F) WB
- Outdoor Temperature 35°C(95°F) DB/24°C(75.2°F) WB
Heating: - Indoor Temperature 20°C(68°F) DB/15°C(59°F) WB
- Outdoor Temperature 7°C(44.6°F) DB/6°C(42.8°F) WB
Piping Length - Interconnecting Piping Length 7.5m
- Level Difference of Zero
2. Wiring cable size must comply with the applicable local and national
code.
3. The specification may be subject to change without notic for purpose
of improvement.