Intelbras IVP 3011 Cortina User manual

Type
User manual
User’s Manual
IVP 3011 Cortina (Curtain)
IVP 3011 Cortina (Curtain)
Infrared passive sensor
Congratulations, you just have purchased a product with Intelbras
quality and safety.
The IVP 3011 Cortina sensor is suitable for doors and windows pro-
tection. It can detect with angle of 15° through passive infrared rays,
allowing effective detection and reduced false triggers. Read the prod-
uct introductory information carefully for the correct use of the sensor.
Caution and safety
» LGPD - General Law for the Protection of Personal Data: Intelbras does not access,
transfer, capture, or perform any other type of treatment of personal data from
this product.
» Follow all instructions of the manual for product mounting and installation.
» This movement sensor is to be used in indoor environments.
» Do not touch on surface of the infrared sensor (PIR). If necessary, use a soft cloth
with alcohol to clean it.
» To clean the plastic cabinet, use a damp soft cloth or with alcohol.
» The sensor must be installed where a possible intruder could be easily detected,
that is, where a person does transversal movements in relation to the sensor de-
tection beams when entering in to the environment. The suggested installation
height is 2.2m.
» Do not put objects that can block scan in front of the sensor.
» Avoid installing the sensor near to the following interference sources: reexive
surface, areas with sudden temperature changes such as air conditioners and he-
aters, fans, refrigerators and ovens.
» Avoid installing in places where sunlight goes directly on to the sensor.
» Install the sensor in a stable and shake-free place.
» For your safety, perform test of product and systems at least once a week. It is
necessary due to changes in environmental conditions, electronic failures or power
outage and aws. Take all the required precautions to keep your property safe
and protected.
Upper view scan
0 m 2 m 4 m 6 m
Detection range (side view)
6 m
4 m
2 m
2,2 m Side view
0 m
Terminal block
» Tamper: Anti-tamper key
» (-) GND: negative source
» (+) 12 V: Positive source
» Alarm: Sensor output
Alarm
Tamper
GND +12
Summary
1. Technical specications 6
2. Producto 6
3. Features 7
4. Installation 7
5. Operation 10
6. Test 12
Term of Warranty 13
6
1. Technical specications
Operating voltage 9 a 16 Vdc
Operating current ≤18 mA
Operating temperature -10°C to 50 °C
Detection method PIR
Detection distance 6m
Alarm output NC – NA(500 mA 100 Vdc)
Recommended installation height 2.2 m
Startup time 60s
Detection angle 15°
Anti-tamper key (TAMPER) NC
Size 80 × 35 × 30 mm
LED ON - OFF
Detection pulse (P. COUNT) 1P – 2P
Note:
the infrared detection range can be inuenced by the environment.
2. Producto
4
3
9
8
7 6
6
10 11 12
13
2
1
4
5
7
1. Front
2. Lens
3. Base
4. Bolt xation holes
5. Cable passage
6. Terminal Block
7. Tamper Key
8. PIR Sensor
9. LED indicator
10. Jumper LED
11. Jumper P.COUNT(pulse counter)
12. Jumper relay
13. Wall bracket (Bracket)
3. Features
» Easy to install.
» Suitable for protecting windows, doors and corridors.
» Automatic temperature compensation.
» Anti-tamper protection (tamper key).
» Adjustable infrared sensitiveness (PIR).
» Optional NC and NO relay output.
4. Installation
» Execute the installation in an area free of obstacles that may hinder the visual
eld of the sensor.
» The PIR (P-COUNT) sensitivity adjustment must be done according to each envi-
ronment.
To attach the sensor in the ceiling, follow the procedure:
1. Using a thin driver, tighten the locks on the side of the sensor and remove the front
cover. (Fig 1)
2. Tear the plastic and pass the cable through the cable passage orice in the back
cover. (Fig. 2).
3. Connect cable in the terminal block.
8
Figure 2 Figure 3
Cable entry Cable
To install directly in the wall without bracket
1. Tear the base of the plastic bag to pass the bolts, as indicated. (Fig 3)
2. Attach the sensor, passing the screw through the holes in the back cover. (Fig. 4).
Note: M3X25 self-drilling screws.
Figure 3 Figure 4
Screw
Screw
Rear cover
Rompa aqui
Rompa aqui
9
For installation using the bracket
1. Attach the bracket in the wall, passing the screw through the holes on the side
(Fig 5)
2. Fit the sensor into the bracket (Fig. 6).
3. To remove the sensor from the bracket, just use a small driver as a lever in the lock
on the left side (Fig. 7).
Note: M3X25 self-drilling screws.
Figure 5 Figure 6 Figure 7
For protection of doors and windows, install the sensor on the side.
90º
15º
6 m
IVP 3011 curtain
2,2 m
90 cm
10
Corridor protection.
Sensor
5. Operation
LED jumper is used for LED indication without interfering with the detector. Jumper
in ON position (pin 1 & 2) light on. Jumper in OFF position (pin 2 & 3) light off.
Factory standard: LED on.
The P.COUNT jumper controls the pulse count for alarm activation. With the jumper
in the 1P position, the sensor provides maximum sensitivity (one pulse, pins 1 & 2)
With the jumper in the 2P position, the sensor provides intermediary sensitiveness
(two pulses, pins 2 & 3), and in this position, the sensor provides proper detection
for environments with high incidence of EMI and RFI interferences. Factory stan-
dard: 2P.
Note: if the P.Count jumper is open, the sensor sensitivity will be 2P.
The RELAY jumper controls the relay contact status. With jumper in the NC position,
the contact is normally closed. With jumper in the NO position, the contact is
normally open. Factory standard: NC
11
Relay P.Count LED
Jumper P.COUNT
Position Condition
1 P 1 Pulse – maximum sensitivity
2 P 2 Pulse - minimum sensitivity
Jumper relay
Position Condition
NC Normally closed
NO Normally open
Jumper LED
Position Condition
ON LED on
OFF LED off
12
6. Test
When energized, the LED lights on, indicating that the self-test has been activated
by the sensor.
It performs the walk-through test, with transversal movements to sensor detection,
by observing the LED indication.
Note: while a movement could be detected, the LED remains on and will indicate
open or closed.
Walk through the area where you want to protect to check if it is within the area
covered by the sensor. The sensor sensitivity and its installation position will dene
the coverage area.
6 m
4 m2 m
2,2 m
0 m
13
Term of Warranty
It is expressed that this contractual warranty is granted according to the following
conditions:
Customer name:
Customer’s signature:
Tax Invoice No.
Date of Purchase:
Model: Serial No.:
Retailer
1. All parts, pieces and components of this product are warranted against any man-
ufacturing defects, which may arise within a period of 1 (one) year - being 90
(ninety) days of legal warranty and 9 (nine) months subject to contractual warran-
ty - from the date when the Customer purchased the product, according to the
product purchase tax invoice, which is an integral part of this Term throughout
the Brazilian territory. This contractual warranty expressly includes the product ex-
changes in case of manufacturing defect. If no manufacturing defect is conrmed,
but there is a failure due to improper use, the Customer shall bear any of these
incurred expenses.
2. The product must be installed according to the Product Manual and/or Installation
Guide. If your product requires to be installed and congured by a skilled techni-
cian, your should seek for a reliable and skilled professional, but the costs of such
services are not included in the product price.
3. Once the defect is conrmed, the Customer shall contact immediately the nearest
Authorized Service listed in the report provided by the manufacturer, they are the
only professionals authorized to check and remedy the defect within the warranty
term provided herein. It it is not observed, the warranty is void, characterized as
product infringement.
4. Eventually, if the Customer requests service at home, he/she may contact the near-
est Authorized Service to ask for fee quotation of a technical visit. If it is necessary
to withdraw the product to be repaired, the incurred expenses such as transpor-
14
tation and insurance costs, including taking and return after repaired, are under
responsibility of the customer.
5. The warranty will be entirely voided if any of the following cases occur: a) if the
defect is not due to manufacturing, but caused by the Customer or by third parties
foreign to the manufacturer; b) if the product damages are caused by accident,
disasters, agents of nature (lightning, ooding, landslide, etc.), humidity, network
voltage, over-voltage caused by accident or excessive network voltage uctua-
tions), installation/use in disagreement with the user’s manual or due to natural
wear of parts, pieces and components; c) if the product had suffered any effects of
chemical, electromagnetic, electric or animal (insects, etc.) nature; d) if the product
serial number was altered or erased; and e) if the appliance is awed.
6. This warranty does not cover data loss, therefore, in case of a product, it is advis-
able to the Customer to regularly make secure backup of the product data.
7. Intelbras is not liable for the installation of this product, as well as eventual at-
tempts of fraud and/or sabotage in their products. Keep software and applications
up to date, and if necessary, the required network protections against intrusions
(hackers). The equipment is warranted against defects under normal conditions of
use, and it is important to bear in mind that, because it is an electronic equipment,
it is not protected from attempts of frauds or misleading actions that may interfere
in its correct operation,
8. After its useful life, the product must be delivered to an Intelbras authorized sup-
port service or perform environmentally proper nal disposal in order to avoid
environmental or health impacts. If you prefer, useless cells and batteries as well
as other Intelbras branded electronic appliances may be disposed at any Green
Eletron collection points (electro-electronic residues management company to
which we are associated). If you have any questions about the reverse logistics
process, contact us by phone (48) 2106-0006 or 0800 704 2767 (from Monday to
Friday at 8 AM to 8 PM, and on Saturday at 8 AM to 6 PM) or via e-mail suporte@
intelbras.com.br.
Also under these supplementary Term of Warranty, Intelbras S/A reserves the right
to alter general, technical or aesthetics features without prior notice.
The manufacturing process of this product is not subject to ISO 14001 require-
ments.
All images in this manual are for illustrative purposes only.
01.21
Made in China
Customer Support: (48) 2106 0006
Forum: forum.intelbras.com.br
Support via chat: intelbras.com.br/suporte-tecnico
Support via e-mail: [email protected]
Customer Service: 0800 7042767
Where to buy? Who installs it? 0800 7245115
Imported to Brazil by: Intelbras S/A – Indústria de Telecomunicação Eletrônica Brasileira
Rodovia SC 281, km 4,5 – Sertão do Maruim – São José/SC – 88122-001
CNPJ 82.901.000/0014-41 – www.intelbras.com.br
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15

Intelbras IVP 3011 Cortina User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI