Quick Installation Manual
Dual Path (LAN + Cellular) Communicator with with serial port interface for
Texecom Premier and Elite panels and Paradox 17x8, SP, MG and EVO panels
Connecting the communicator to the alarm panel
(+) 12VDC Power Supply
(-) Ground
Rx, Tx For optional integration with supported panels via serial port
IN1 Status
IN2 Alarm
IN3 Tamper
IN4 Panic
IN5 Alarm
IN6 Alarm
IN7 Alarm
IN8 Alarm
WARNING: The wiring should be done only when the panel and the communicator are
disconnected from the powerline!
Connect the antenna to the device and place the antenna outside of the alarm panel’s box
Connect + and – of the communicator to 12V-15V DC power supply
LED Indicator
Slow flashing – trying to establish connection
Constantly On – connection established at good signal level
Constantly On, blinking every 10 secs – connection established at low signal level
Fast flashing – transferring data
Connecting the communicator to the LAN network
Connect the device to a DHCP enabled router via an Ethernet cable. It will automatically
get a dynamic IP address
External IP address or router port redirections are NOT needed
Selecting the model of the alarm panel
(when using the serial port interface)
Enter in the RControl Administrative website. Open the “Device Dashboard” and navigate to
“Advanced Settings”
Check the “Enable Online Settings” checkbox and press “Get Current Settings” (the device
should be powered and connected)
From the “COM 1”-> “Events” drop box menu select the alarm panel’s model
Click “Save” to confirm the changes
Configuring a backup of the alarm events
(when using the serial port interface)
Configure a PGM of the panel to be activated (switch to ground) in case of any alarm event
(refer to the panel’s installer manual)
Wire that PGM to IN2 of the communicator (programmable input, preconfigured as Alarm)
Configuring Texecom alarm panels
(when using the serial port interface)
You must program the UDL password on the Texecom panel.
Programming the UDL Password on Premier Elite panels:
Enter in the programming menu with the engineers code (default 1234)
Navigate to "UDL/Digi Options" and press "Yes" or "√" to enter
Navigate to "UDL options" and enter the menu by pressing "Yes" or "√"
Navigate to "UDL Password" and press "NO" or "X" to edit the password
Enter the default UDL password 1234.
Programming a UDL Password on Premier panels:
Enter in the programming menu with the engineers code (1234) + "menu" + "9"
Enter "76" to access "Download menu" and "2" for "UDL password"
Enter the default UDL password 1234.
NOTE! If you configure an UDL password on the panel different than 1234, you need to
specify the same password also in the settings of the communicator:
Enter in the RControl Administrative website and navigate to “Device Dashboard”
Click on “Advanced Settings” and Check the “Enable Online Settings” checkbox
Press “Get Current Settings” (the device should be powered and connected)
Change the “Pass1” in “COM 1” section to correspond to the new UDL password
Click on Save to confirm the changes
Events reporting to end users via a smartphone
Download the RControl mobile application on your Android or iOS from the links
below
Login with the end user credentials provided within this installation manual
It is recommended to change the User name and Password after the first login
With the RControl mobile application the end user can:
Monitor the current status of the alarm panel
Get real-time notifications
View events log up to one year back in time
Remotely Arm/Disarm the alarm system (optional)
RControl App download links: RControl App credentials:
v.2.1_20190924