Hisense R32 Air Conditioner User manual

  • Hello! I've reviewed the Hisense R32 Air Conditioner User Guide and understand the installation, safety measures, and operational details. I can assist with questions on features like the inverter compressor, R32 refrigerant, and intelligent cooling options. Feel free to ask me anything about the document.
  • What safety precautions should I take when installing the air conditioner?
    Can children use the air conditioner?
    What are the recommended fuses for the indoor and outdoor units?
Hisense
R32 Air
Conditioner
User Guide
Introduction
The iRobot Roomba j6 is a cutting-edge robot vacuum cleaner designed and manufactured by
iRobot, a renowned company known for its innovative home robotics solutions. Released as part of
the Roomba series, the j6 model represents a significant advancement in autonomous cleaning
technology, making it easier and more efficient to maintain a clean and tidy home.
The Roomba j6 is equipped with a host of features that set it apart from traditional vacuum cleaners.
It utilizes advanced mapping and navigation technologies to intelligently navigate through your home,
creating a map of the environment as it cleans. This intelligent mapping allows the Roomba j6 to
efficiently clean in straight lines, avoid obstacles, and navigate around furniture, ensuring thorough
coverage of your floors.
One of the standout features of the Roomba j6 is its powerful cleaning system. The robot vacuum
comes equipped with a high-efficiency filter and a robust suction system that can capture and remove
dirt, dust, pet hair, allergens, and debris from various floor surfaces, including hardwood, tile, carpet,
and laminate. This makes the j6 ideal for homes with pets or individuals with allergies.
The Roomba j6 also boasts smart home integration, allowing you to control and schedule cleaning
sessions through your smartphone or smart home assistant like Amazon Alexa or Google Assistant.
You can initiate cleaning remotely, set custom cleaning preferences, and receive notifications about
the cleaning progress and status.
Additionally, the Roomba j6 is part of iRobot's broader ecosystem, enabling seamless integration with
other iRobot home robots and smart devices. This ecosystem approach allows for enhanced
automation and coordination within your smart home.
In summary, the iRobot Roomba j6 is an advanced and feature-rich robot vacuum cleaner that
combines intelligent mapping, powerful cleaning capabilities, and smart home integration to take the
hassle out of maintaining a clean and tidy living space. With the Roomba j6, you can enjoy a cleaner
home with minimal effort, leaving you with more time for the things you love.
About this item
Split AC with inverter compressor: Variable speed compressor which adjusts power depending on
heat load. It is most energy efficient and has lowest-noise operation.
Capacity: 1.5 Ton suitable for small sized rooms (151 to 200 square feet).
Energy rating: 5 star, Annual energy consumption: 865.67 units, ISEER value: 4.65. (please refer
energy Label on product page or contact brand for more details).
Warranty: 1 Year on Product (Comprehensive), 10 Years on Compressor.
Copper: The AC comes with 100% Grooved Copper that gives better cooling and requires low
maintenance, increases the durability of air conditioner.
Special Features: Intelligent smart cooling, intelligent fast cooling, intelligent health filters, intelligent
i-feel, intelligent super cooling, intelligent sleep, stabilizer free operation.
Refrigerant gas: R32 that is environmental friendly with no ozone depletion potential.
IDU Net Dimension: 896x214x300
Included Components: 1 Indoor unit, 1 outdoor unit, inter Connecting pipe, 1 remote, 1 Manual, 1
Warranty card, 2 batteries, inter Connecting wire.
Installation diagram
The above figure is only a simple presentation of the unit, it may not match the external appearance of
the unit you purchased. Installation must be performed in accordance with the national wiring
standards by authorized personnel only.
Select the installation locations
Location for Installing Outdoor Unit
Where it is convenient to install and well ventilated.
Avoid installing it where flammable gas could leak.
Keep the required distance apart from the wall.
The pipe length between indoor and outdoor units should be no more than 5 meters in factory
default status, but it can go up to maximum 20 meters with an additional refrigerant charge.
Keep the outdoor unit away from greasy dirt, vulcanization gas exit.
Avoid installing it by the roadside where there is a risk of muddy water.
A fixed base where it is not subject to increased operation noise.
Where there is not any blockage of the air outlet.
Avoid installing under direct sunlight, in an aisle or sideway, or near heat sources and ventilation
fans.
Keep away from flammable materials, thick oil fog, and wet or uneven places.
If the height or pipe length is out of the scope of the table, please consult the merchant.
Connecting of the Cable
Note: For some models, it is necessary to remove the cabinet to connect to the indoor unit terminal.
Outdoor Unit
1. Remove the access door from the unit by loosening the screw. Connect the wires to the
terminals on the control board individually as follows.
2. Secure the power cord onto the control board with a cable clamp.
3. Reinstall the access door to the original position with the screw.
4. Use a recognized circuit breaker for 24K model between the power source and the unit. A
disconnecting device to adequately disconnect all supply lines must be fitted.
The figures in this manual are based on the external view of a standard model. Consequently, the
shape may differ from that of the air conditioner you have selected.
Caution:
Never fail to have an individual power circuit specifically for the air conditioner. As for the method of
wiring, refer to the circuit diagram posted on the inside of the access door.
Confirm that the cable thickness is as specified in the power source specification
Check the wires and make sure that they are all tightly fastened after the cable connection.
Be sure to install an earth leakage circuit breaker in wet or moist areas.
Cable Specifications
Attention:
The plug must be accessible even after the installation of the appliance in case there is a need to
disconnect it. If not possible, connect the appliance to a double-pole switching device with a contact
separation of at least 3 mm placed in an accessible position even after installation.
Wiring diagram
Make sure that the color of the wires in the outdoor unit and terminal No. are the same as those of the
indoor unit.
7K~24K Model
Warning: Before obtaining access to terminals,all supply circuits must be disconnected.
Outdoor unit installation
1. Install Drain Port and Drain Hose (for heat-pump model only) The condensate drains from the
outdoor unit when the unit operates in heating mode. In order not to disturb your neighbor and
protect the environment, install a drain port and a drain hose to direct the condensate water. Just
install the drain port and rubber washer to the chassis of the outdoor unit, then connect a drain
hose to the port as the right figure demonstrates.
2. Install and Fix Outdoor Unit Fix with bolts and nuts tightly on a flat and strong floor. If installed on
the wall or roof, make sure to fix the supporter well to prevent it from shaking due to serious
vibration or strong wind.
3. Outdoor Unit Piping Connection Remove the valve caps from the 2-way and 3-way valves.
Connect the pipes to the 2-way and 3-way valves separately according to the required torque.
4. Outdoor Unit Cable Connection (see the previous page)
Air purging
The air which contains moisture remaining in the refrigeration cycle may cause a malfunction on the
compressor. After connecting the indoor and outdoor units, release air and moisture from the
refrigerant cycle using a vacuum pump, as shown below.
Note: To protect the environment, be sure not to discharge the refrigerant to the air directly. See next
page for air purging steps.
How to Purge Air Tubes:
Unscrew and remove caps from 2 and 3-way valves. Unscrew and remove the cap from the service
valve. Connect vacuum pump flexible hose to the service valve. Start vacuum pump for 10-15 minutes
until reaching a vacuum of 10 mm Hg absolutes. With the vacuum pump still running close the
low-pressure knob on the vacuum pump manifold. Then stop the vacuum pump. Open the 2-way
valve,1/4 turn, then close it after 10 seconds. Check the tightness of all joints using liquid soap or an
electronic leak detector. Turn 2 and 3-way valves stem to fully open the valves. Disconnect the flexible
vacuum pump hose. Replace and tighten all valve caps.
/