DANGER! To reduce risk of explosion, do not install in machinery space or in areas where ignition-
protected equipment is required to be used.
CAUTION! This unit is NOT designed for weather exposed installation. To reduce risk of electrical
shock and unit damage, do not expose to rain or spray.
FOR INDOORS USE ONLY!
The AC output is intended to be used with 15 Amp NEMA 5-15P plugs with no smaller than AWG
#16 copper conductors.
Over current protection (AC breakers) have NOT been provided and must be provided by the
installer / user. Listed 15A breakers per NEC requirements should be included in installation.
This unit has been provided with integral protections against overloads.
WARNING! To reduce risk of electric shock and fire:
Installation should be carried out by certified installer and as per Local and National Electrical
Codes
Do not connect to circuit at more than 150 Volts to Ground
Do not connect directly to AC Load Center (Circuit Breaker Panel) having Multi-wire Branch
Circuits connected
Do not mount in zero clearance compartments
Do not cover or obstruct ventilation openings
If the Goal Zero Yeti needs to be removed from the system, always remove the Ground terminal
from the Goal Zero Yeti first. Make sure all accessories are off. Ensure the Yeti inverter is in the off
position, so that you do not cause a spark.
IMPORTANT SAFETY INSTRUCTIONS
THESE INSTRUCTIONS CONTAIN IMPORTANT INSTRUCTIONS FOR MODELS: YETI
1000X, YETI 1000 CORE, YETI 1500X, YETI 3000X, YETI 6000X
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING UNIT INTO ANY VEHICLE
TO PREVENT PERSONAL INJURY OR DAMAGE TO THE UNIT.
WARNING!
GOAL ZERO YETI® INSTALLATION GUIDE